Lymphedema Assessment –Development of a Diagnostic Tool
KTH, School of Industrial Engineering and Management (ITM), Machine Design (Dept.).
2012 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesisAlternative title
Utveckling av ett diagnosverktyg för lymfödem (Swedish)
Abstract [sv]

En ny produkt, som utvecklats för att underlätta de många diagnoser och bedömningar avsjukdomen lymfödem, utvärderades och vidareutvecklades i denna studie. Tidiga mätningar avpatienter i riskzonen var viktigt för en tidig upptäckt av sjukdomen. Lymfödem yttrar sig somsvällande och förhårdnade kroppsdelar, ofta armar och ben, och uppkommer delvis till följd avcancerbehandling. De mätmetoder som användes inom vården när rapporten skrevs, bestod aven lång rad mätningar av kroppsdelars omkrets med ett vanlig måttband. Det fanns utrymme förförbättring av metoden som kunde göras mer konsekvent och effektiv. En risk fanns att klinikeranvände måttbandet på olika sätt när omkretsar på patienter mättes. Dessutom skulle denhårdhetsutvärdering av kroppsdelar, som genomfördes av klinikerna, kunna kvantifieras ochanalyseras om dessa utvärderingar sattes i siffror.Målen med detta projekt var att utvärdera den nya produktens noggrannhet och precision, samtutveckla och integrera en funktion för mätning av hudens hårdhet. Ett användargränssnittanpassad till klinikers krav och en konstruktion anpassad för testning och framtida tillverkning,var också projektmål. Med anledning av patientsäkerhetskrav gjordes en del av produktenutbytbar mellan mätningar av olika patienter.Under utvecklingen användes videoinspelningar av praktiska tester av prototypen ochundersökning som delades ut till kliniker som utförde lymfödembehandling. Mätningen avomkrets som utvecklats i denna studie var, enligt de tester som utförts, tillräckligt noggrannjämfört med den noggrannhet den vedertagna mätmetoden krävde. En automatisk beräkning aven bulkmodul K för vävnaden, utvecklades som en integrerad funktion för att kunna erhålla ettvärde på den hårdhet som kliniker kände med sina händer. K-värdet visade sig fungera som ettkoncept, genom mätningar av olika typer av skummaterial. Beträffande mätningar i vävnadvisade sig produktens bestämning av K-värden kunna detektera en ökning av muskelspänning,men resultaten var bara förutsägbara till en viss gräns i testet som presenteras i rapporten.Metoden kunde i denna studie, inte på detta sätt valideras för vävnad genom att jämförametoden med mätningar med en durometer. En av slutsatserna var dock att K-värdet fortfarandekunde vara en användbar indikator, som ett komplement till den bedömning som var gängse närrapporten skrevs. Utöver detta kunde produkten spara tid i de många mätningarna avlymfödempatienter. Denna sparade tid kunde användas för fler mätningar. Fler mätningar ökarchansen att upptäcka sjukdomen i ett tidigt stadium (Lawenda, Mondry, and Johnstone, 2009),vilket i sin tur är avgörande för en framgångsrik behandling.

Abstract [en]

To improve the frequently performed lymphedema measuring session – important for an earlydetection of the disease – a novel device was evaluated and further developed in this study.Lymphedema appears as limbs swelling, often arms and legs, partly because of cancertreatment. The current assessment technique includes several circumference measurements witha regular tape measure, and the method had room for improvement regarding consistency andeffectiveness. Different clinicians may pull the tape measure differently while measuring thecircumferences of a patient’s limb. An additional skin compliance evaluation, performed by theclinicians, could be quantified and analyzed if the assessments were put into numbers.The goals of this project were to evaluate and improve the accuracy and precision of this noveldevice, as well as develop and integrate a feature for measuring skin compliance. Furthermore,a user interface adapted to the clinicians’ demands and a design adapted to testing and futuremanufacturing was essential. Due to patient safety reasons, a part of the device was madereplaceable between patients.Developing the device, video recordings of hands-on testing were performed, as well as asurvey distributed to clinicians who provided lymphedema therapy. The circumferencemeasurement developed in this study was, according to the performed tests, accurate enoughcompared to the accuracy required the current measuring routine. An automatic calculation of askin bulk modulus K, was developed as a feature of the device to be able to obtain a value ofthe compliance clinicians felt for with their hands. The K-value was proven as a concept bymeasuring different foams. Measuring K-values of the tissue, the device was capable ofdetecting an increase in muscle tension, but results were only predictable to a certain limit inthe test presented in the report. The method could not yet be validated by comparing it to a skinhardness measurement with a durometer. A conclusion was however, that the K-value stillcould be a useful indicator in addition to the current assessment and that the device could savetime in the measuring session. This saved time could be used for more measurement sessions,beneficial in order to detect lymphedema early (Lawenda, Mondry, and Johnstone, 2009),which in turn was essential for a successful treatment.

Place, publisher, year, edition, pages
2012. , 84 p.
Series
MMK 2012:62 MCE 266
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:kth:diva-145063OAI: oai:DiVA.org:kth-145063DiVA: diva2:716008
Supervisors
Examiners
Available from: 2015-03-06 Created: 2014-05-07 Last updated: 2015-03-06Bibliographically approved

Open Access in DiVA

fulltext(19955 kB)22 downloads
File information
File name FULLTEXT01.pdfFile size 19955 kBChecksum SHA-512
03338cf59d79711de883923c3a75e525fd74817dcdba0d1fe0b119b490285dc814c3dba10f57fd3e176f5c73282b03f15d008b7d5f69dfba34746b61274808b5
Type fulltextMimetype application/pdf

By organisation
Machine Design (Dept.)
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 22 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 93 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf