Off-resonance correction for magnetic resonance imaging with spiral trajectories
KTH, School of Technology and Health (STH), Medical Engineering.
2014 (English)Independent thesis Basic level (university diploma), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

The procedure of cardiographic magnetic resonance imaging requires patients to hold their breath for up to twenty seconds, creating an uncomfortable situation for many patients. It is proposed that an acquisition scheme using spiral trajectories is preferable due to their much shorter total scan time; however, spiral trajectories suffer from a blurring effect caused by off-resonance frequencies in the image area.

There are several methods for reconstructing images with reduced blur and Conjugate Phase Reconstruction has been chosen as a method for implementation into Matlab-script for evaluation in regards to image reconstruction quality and computation time. This method finds a conjugate to the off-resonance from a field map to demodulate the image and an algorithm for frequency‑segmented Conjugate Phase Reconstruction is implemented along with an improvement called Multi-frequency Interpolation.

The implementation is tested through simulation of spiral magnetic resonance imaging using a Shepp‑Logan phantom. Different off-resonance frequencies and field maps are used to provide a broad view of the functionality of the code. The two algorithms are then compared to each other in terms of computation speed and image quality.

It is concluded that this implementation might reconstruct images well but that further testing on actual scan sequences is required to determine the usefulness. The Multi-frequency Interpolation algorithm yields images that are not useful in a clinical context. Further study of other methods not requiring a field map is suggested for comparison.

Place, publisher, year, edition, pages
2014. , 19 p.
TRITA-STH, 2014:49
Keyword [en]
MRI; blur; spiral; inhomogeneity; off-resonance correction.
National Category
Medical Image Processing
URN: urn:nbn:se:kth:diva-147925OAI: diva2:733289
Subject / course
Medical Engineering
Educational program
Master of Science in Engineering - Medical Engineering
Available from: 2014-08-27 Created: 2014-07-08 Last updated: 2014-08-27Bibliographically approved

Open Access in DiVA

andreas_kex(3292 kB)445 downloads
File information
File name FULLTEXT01.pdfFile size 3292 kBChecksum SHA-512
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Nylund, Andreas
By organisation
Medical Engineering
Medical Image Processing

Search outside of DiVA

GoogleGoogle Scholar
Total: 445 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 103 hits
ReferencesLink to record
Permanent link

Direct link