Change search
ReferencesLink to record
Permanent link

Direct link
The pulmonary capillary wedge pressure accurately reflects both normal and elevated left atrial pressure
KTH, School of Technology and Health (STH).
Show others and affiliations
2014 (English)In: American Heart Journal, ISSN 0002-8703, E-ISSN 1097-6744, Vol. 167, no 6, 876-883 p.Article in journal (Refereed) Published
Abstract [en]

Background Pulmonary capillary wedge pressure (PCWP) is routinely used as an indirect measure of the left atrial pressure (LAP), although the accuracy of this estimate, especially under pathological hemodynamic conditions, remains controversial. Objectives The aim of this prospective study was to investigate the reliability of PCWP for the evaluation of LAP under different hemodynamic conditions. Methods Simultaneous left and right heart catheterization data of 117 patients with pure mitral stenosis, obtained before and immediately after percutaneous mitral comissurotomy, were analyzed. Results A strong correlation and agreement between PCWP and LAP measurements was demonstrated (correlation coefficient = 0.97, mean bias +/- CI, 0.3 +/- -3.7 to 4.2 mm Hg). Comparison of measurements performed within a 5-minute interval and those performed simultaneously revealed that simultaneous pressure acquisition yielded better agreement between the 2 methods (bias +/- CI, 1.82 +/- 1.98 mm Hg). In contrast to previous observations, the discrepancy between the 2 measures did not increase with elevated PCWP. Multiple regression analysis failed to identify hemodynamic confounders of the discrepancy between the 2 pressures. The ability of PCWP to distinguish between normal and elevated LAP (cutoff set at 12 and 15 mm Hg, respectively), as tested by receiver operating characteristics analysis, demonstrated a remarkably high diagnostic accuracy (area under the curve: 0.989 and 0.996, respectively). Conclusions Although the described limits of agreement may not allow the interchangeability of PCWP and LAP, especially at lower pressure ranges, our data support the clinical use of PCWP as a robust and accurate estimate of LAP.

Place, publisher, year, edition, pages
2014. Vol. 167, no 6, 876-883 p.
Keyword [en]
National Category
Cardiac and Cardiovascular Systems
URN: urn:nbn:se:kth:diva-148307DOI: 10.1016/j.ahj.2014.01.012ISI: 000338350800017PubMedID: 24890538ScopusID: 2-s2.0-84901806830OAI: diva2:736472

QC 20140806

Available from: 2014-08-06 Created: 2014-08-05 Last updated: 2014-08-06Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMedScopus

Search in DiVA

By author/editor
Venkateshvaran, AshwinWinter, ReidarManouras, Aristomenis
By organisation
School of Technology and Health (STH)
In the same journal
American Heart Journal
Cardiac and Cardiovascular Systems

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 27 hits
ReferencesLink to record
Permanent link

Direct link