A consumers´testing approach to the usability of medical technology: Insulin pumps and CGM systems
KTH, School of Technology and Health (STH), Centres, Centre for Health and Building, CHB.ORCID iD: 0000-0002-4068-6794
KTH, School of Technology and Health (STH), Health Systems Engineering, Systems Safety and Management.ORCID iD: 0000-0001-8747-9277
KTH, School of Technology and Health (STH), Health Systems Engineering, Systems Safety and Management.
2014 (English)In: Advances in Safety Management and Human Factors, 2014, 117-128 p.Conference paper, Published paper (Refereed)
Abstract [en]

Five different insulin pumps and three systems for continuous glucose monitoring were subjected to usability tests at the School of Technology and Health. Each pump was trialed and rated by 30 respondents; 20 students with no experience of diabetes and 10 diabetic pump users. Each of the CGM systems was trialed and rated by 10 non-diabetic students. All participating students were enrolled in Medical Technology (Royal Institute of Technology) or Occupational Therapy (Karolinska Institute). The technical performance of pumps and CGM systems was tested independently. The respondents handled the insulin container, the oftware, the buttons, the screen and the manual through five scenario-based tasks. The trials and the accompanying attitude items were based on the ISO definition of usability. Efficiency was measured as the proportion of respondents succeeding to perform the tasks in less than 15 minutes, combined with the average time to do so. Effectiveness was the quotient of success frequency over average performance time. Satisfaction was the average distribution on the attitude items related to software, screen, buttons and manual. All products were ranked against each other within each separate test and the rank scores accumulated. There  were significant differences in the scoring of the individual insulin pumps and CGM systems.

Place, publisher, year, edition, pages
2014. 117-128 p.
Keyword [en]
Usability Testing, Medical Technology, Diabetes
National Category
Engineering and Technology Other Medical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-157802ISBN: 9781495121005 (print)OAI: oai:DiVA.org:kth-157802DiVA: diva2:772222
Conference
Applied Human Factors and Ergonomics Conference (AHFE2014); Krakow, Poland, 19-23 July, 2014
Note

20150128

Available from: 2014-12-16 Created: 2014-12-16 Last updated: 2015-01-28Bibliographically approved

Open Access in DiVA

No full text

Authority records BETA

Larsson, Tore JAminoff, Hedvig

Search in DiVA

By author/editor
Larsson, Tore JAminoff, HedvigMridha, Mannan
By organisation
Centre for Health and Building, CHBSystems Safety and Management
Engineering and TechnologyOther Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 87 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf