The air distribution in buildings with combined natural and mechanical ventilation
KTH, Superseded Departments, Civil and Architectural Engineering.
2004 (English)Licentiate thesis, comprehensive summary (Other scientific)
Abstract [en]

This work describes result from both measurements on anumber of one family houses, an analytical study of a one-zonemodel and multi zone studies of a two storey building. Thesimulations are performed as both parametric studies, withcombined values of outside temperature, wind velocity and winddirection, and whole year simulations. For the latter, aclimate file for the northern Swedish city Östersund isused.

The results, for the whole year simulations, are presentedas ventilation availabilities. The ventilation availability isdefined as the relative time of the heating season during whicha specified airflow is exceeded. This specified airflow maye.g. be a Building Code requirement if such exists.

The influence of different measures, and combinations ofmeasures, on the ventilation availability has been determinedfor the different rooms. It is found that acceptableventilation availability is possibly to achieve with naturalventilation. However, it requires large supply and overflowopenings and extended ventilation chimneys. These chimneys maybe difficult to accept from an esthetical point of view. Thenatural system is also very sensitive for changes in winddirection.

To ensure required airflows at all times, an exhaust orhybrid ventilation system may be necessary.

Some recommendations may be based on this study.

-Consider the predominating wind direction. It’san advantage to have more supply openings on the leeward side,i.e. to place“humid”rooms towards the knownwindward side.-Use different chimney heights from the different“humid”rooms, to balance the internal airflows. Ifmechanical exhaust is used, it may be used only from some ofthe“humid”rooms, preferable the ones with closeddoors.-Use as large supply and overflow openings aspossible. Different opening areas may be used to balance theairflows, especially if the predominating wind direction isknown. Acoustic problems may be a limiting factor for theopening area. There may also exist a maximum opening area abovewhich stability problems occur.-Construct ventilation chimneys and chimney outlets ina way, that the windgenerated pressure at the outlet is alwaysnegative and independent of wind direction. Insulate thechimneys to avoid cooling of the air and decreased buoyancyforces.

-Use different chimney heights from the different“humid”rooms, to balance the internal airflows. Ifmechanical exhaust is used, it may be used only from some ofthe“humid”rooms, preferable the ones with closeddoors.

-Use as large supply and overflow openings aspossible. Different opening areas may be used to balance theairflows, especially if the predominating wind direction isknown. Acoustic problems may be a limiting factor for theopening area. There may also exist a maximum opening area abovewhich stability problems occur.

-Construct ventilation chimneys and chimney outlets ina way, that the windgenerated pressure at the outlet is alwaysnegative and independent of wind direction. Insulate thechimneys to avoid cooling of the air and decreased buoyancyforces.

Place, publisher, year, edition, pages
Stockholm: Byggvetenskap , 2004. , 90 p.
Series
Meddelande. Installationsteknik, 61
Identifiers
URN: urn:nbn:se:kth:diva-1762ISBN: OAI: oai:DiVA.org:kth-1762DiVA: diva2:7753
Available from: 2004-07-02 Created: 2004-07-02

Open Access in DiVA

fulltext(845 kB)1832 downloads
File information
File name FULLTEXT01.pdfFile size 845 kBChecksum MD5
7b23fe487eb1d253cddbedd26d0bb5f3a557e78c30b2106a4b39f37b9fa6ff767d1382f9
Type fulltextMimetype application/pdf

By organisation
Civil and Architectural Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 1832 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 601 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf