An inverse design method for a cavity receiver used in solar dish Brayton system
KTH, School of Industrial Engineering and Management (ITM), Energy Technology, Heat and Power Technology. (Concentrated solar power group)ORCID iD: 0000-0003-4134-3520
KTH, School of Industrial Engineering and Management (ITM), Energy Technology, Heat and Power Technology. (Concentrated solar power group)
KTH, School of Industrial Engineering and Management (ITM), Energy Technology, Heat and Power Technology. (Concentrated solar power group)
KTH, School of Industrial Engineering and Management (ITM), Energy Technology, Heat and Power Technology. (Concentrated solar power group)
2014 (English)In: Solar Energy, ISSN 0038-092X, E-ISSN 1471-1257, Vol. 110, 745-755 p.Article in journal (Refereed) Published
Abstract [en]

An inverse design method is developed in order to quickly find possible cavity receiver designs with relative uniform cavity wall surface temperature for a solar dish cavity receiver. In this design method, a heat transfer model of the absorber wall is used for analyzing the main heat transfer process between the cavity wall outer surface, the inner surface and the working fluid. Furthermore, a ray-tracing model based on the parameters of a real dish is utilized for obtaining the solar radiative boundary conditions for the heat transfer model. Impinging jet cooling technology is introduced due to its high heat transfer coefficient in the stagnation area, which can be used for cooling the peak flux on the cavity wall. After applying a well-designed impinging system, the temperature peak on the peak flux region in traditional receiver designs can be mitigated without introducing any over pressure drop problem.

Place, publisher, year, edition, pages
Elsevier, 2014. Vol. 110, 745-755 p.
Keyword [en]
Parabolic dish, Cavity solar receiver, Inverse design method, Impinging
National Category
Energy Engineering
Research subject
Energy Technology
Identifiers
URN: urn:nbn:se:kth:diva-159595DOI: 10.1016/j.solener.2014.10.019ISI: 000347579100069Scopus ID: 2-s2.0-84910682216OAI: oai:DiVA.org:kth-159595DiVA: diva2:786190
Projects
Optimised Microturbine Solar Power system​ (OMSoP)
Funder
EU, FP7, Seventh Framework Programme, FP7-308952​
Note

QC 20150225

Available from: 2015-02-04 Created: 2015-02-04 Last updated: 2017-12-05Bibliographically approved
In thesis
1. Development of an Impinging Receiver for Solar Dish-Brayton Systems
Open this publication in new window or tab >>Development of an Impinging Receiver for Solar Dish-Brayton Systems
2015 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

A new receiver concept utilizing impinging jet cooling technology has been developed for a small scale solar dish-Brayton system. In a typical impinging receiver design, the jet nozzles are distributed evenly around the cylindrical absorber wall above the solar peak flux region for managing the temperature at an acceptable level. The absorbed solar irradiation is partially lost to the ambient by radiation and natural convection heat transfer, the major part is conducted through the wall and taken away by the impingement jets to drive a gas turbine. Since the thermal power requirement of a 5 kWe Compower® micro gas turbine (MGT) perfectly matches with the power collected by the EuroDish when the design Direct Normal Irradiance (DNI) input is 800 W/m2, the boundary conditions for the impinging receiver design in this work are based on the combination of the Compower®MGT and the EuroDish system.

In order to quickly find feasible receiver geometries and impinging jet nozzle arrangements for achieving acceptable temperature level and temperature distributions on the absorber cavity wall, a novel inverse design method (IDM) has been developed based on a combination of a ray-tracing model and a heat transfer analytical model. In this design method, a heat transfer model of the absorber wall is used for analyzing the main heat transfer process between the cavity wall outer surface, the inner surface and the working fluid. A ray-tracing model is utilized for obtaining the solar radiative boundary conditions for the heat transfer model. Furthermore, the minimum stagnation heat transfer coefficient, the jet pitch and the maximum pressure drop governing equations are used for narrowing down the possible nozzle arrangements. Finally, the curves for the required total heat transfer coefficient distribution are obtained and compared with different selected impinging arrangements on the working fluid side, and candidate design configurations are obtained.

Furthermore, a numerical conjugate heat transfer model combined with a ray-tracing model was developed validating the inverse design method and for studying the thermal performance of an impinging receiver in detail. With the help of the modified inverse design method and the numerical conjugate heat transfer model, two impinging receivers based on sintered α-SiC (SSiC) and stainless steel 253 MA material have been successfully designed. The detailed analyses show that for the 253 MA impinging receiver, the average air temperature at the outlet and the thermal efficiency can reach 1071.5 K and 82.7% at a DNI level of 800 W/m2 matching the system requirements well. Furthermore, the local temperature differences on the absorber can be reduced to 130 K and 149 K for two different DNI levels, which is a significant reduction and improvement compared with earlier published cavity receiver designs. The inverse design method has also been verified to be an efficient way in reducing the calculation costs during the design procedure.

For the validation and demonstration of the receiver designs, a unique experimental facility was designed and constructed. The facility is a novel high flux solar simulator utilizing for the first time Fresnel lenses to concentrate the light of 12 commercial high power Xenon-arc lamps. Finally, a prototype of a 253 MA based impinging was experimentally studied with the help of the 84 kWe Fresnel lens based high flux solar simulator in KTH.

Place, publisher, year, edition, pages
Stockholm: KTH Royal Institute of Technology, 2015. xxiv, 111 p.
Series
TRITA-KRV, ISSN 1100-7990 ; 15:05
Keyword
Concentrating solar power; Impinging receiver; Inverse design method; Conjugate heat transfer; High flux solar simulator
National Category
Energy Engineering
Research subject
Energy Technology
Identifiers
urn:nbn:se:kth:diva-177531 (URN)978-91-7595-796-8 (ISBN)
Public defence
2015-12-16, Sal F3, Lindstedtsvägen 26, KTH, Stockholm, 09:30 (English)
Opponent
Supervisors
Projects
Optimised Microturbine Solar Power System , OMSOP
Funder
EU, FP7, Seventh Framework Programme, FP7-308952​
Note

QC 20151123

Available from: 2015-11-23 Created: 2015-11-23 Last updated: 2015-11-23Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textScopushttp://www.sciencedirect.com/science/article/pii/S0038092X14005052

Authority records BETA

Wang, Wujun

Search in DiVA

By author/editor
Wang, WujunXu, HaoxinLaumert, BjörnStrand, Torsten
By organisation
Heat and Power Technology
In the same journal
Solar Energy
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 633 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf