Nyckeltal för energianvändning i lokaler
KTH, School of Industrial Engineering and Management (ITM), Energy Technology, Applied Thermodynamics and Refrigeration.
KTH, School of Industrial Engineering and Management (ITM), Energy Technology, Applied Thermodynamics and Refrigeration.
2015 (Swedish)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesisAlternative title
Key performance indicators for energy use in buildings (English)
Abstract [sv]

Energianvändningen i en lokal redovisas idag endast som kWh per m2. I exempelvis en stor lokalsom inte producerar varken varor eller tjänster kommer energianvändningen vara låg vilket kanbetraktas som positivt. Skolor och forskningslokaler producerar tjänster och produkter vilket ärav samhällsnytta men den höga intensiteten på verksamheten brukar innebära högreenergianvändningen per m2. Målet med detta examensarbete är att kunna presentera alternativanyckeltal för energianvändning som kan appliceras på lokaler och med rapporten förse KTH ochAkademiska Hus med ett eller flera nyckeltal för bättre presentation av energianvändning i lokaler.

För att kunna besvara problemformuleringen som ställts i detta examensarbete har enarbetsprocessbeskrivning utformats. Arbetsprocessen har delats upp i olika faser med ett antaldelmål som specificerats. Fas 1 innefattar en övergripande litteraturstudie om energianvändningfrämst vad gäller lokaler samt en generell studie för energianvändning i Sverige. Utöver detta enanalys samt jämförelse med Akademiska Hus lokaler som hyrs av KTH. Fas 2 innefattar enintervjustudie samt en workshop med syfte att diskutera och använda sig av de berörda parternaserfarenheter för att komma vidare i arbetet. Fas 3 innefattar en fallstudie som genomfördes på tvåbyggnader på KTH Campus, V och L-huset. Syftet med detta är att utifrån de tidigare fasernamed föreslagna och identifierade nyckeltal applicera dessa på ett verkligt fall och jämföra fördelarsamt nackdelar.

Utifrån fas 1 och 2 avgränsades arbetet till att fokusera på analys av nyttjandegraden ochverksamheten för lokalerna på KTH Campus. En modell för bestämmande av nyttjandegradupprättades utifrån det lokala bokningssystemet som är baserat på antalet bokade timmar underen given tidsperiod. Den totala energianvändningen per kvadratmeter för V- och L-huset är 152,3resp. 155,3 kWh per m2. Efter implementeringen av det nya nyckeltalet kan det konkluderas attdifferensen mellan de två valda lokalerna ökar från 2,0 % till 31,3 %. Detta visar att V-huset ärmer energieffektiv om hänsyn tas till nyttjandegraden. Med det nya nyckeltalet kWh per m2N, kanäven de berörda parterna, KTH och Akademiska Hus möjliggöra en annorlundaenergimålsättning för att på så sätt kunna erhålla exempelvis certifiering inommiljöledningssystemet ISO 14001 i vilket ett eller flera energimål är en förutsättning.

Vidare konkluderas att Akademiska Hus bör tillgodose KTH med data för effektuttag per timmeför att lättare kunna identifiera energieffektiviseringsåtgärder samt att eventuellt se övermöjligheten att installera elmätare i byggnaderna för kartläggning av energianvändningen.

Abstract [en]

Today energy usage in a building is accounted for as kWh per m2. In a large building that, forexample, does not produce goods or services will have a low energy usage which can beconsidered positively. However, it should be named that, for example, schools and researchbuildings produce services and products which are for the public good but usually means greaterenergy usage per m2. The goal of this thesis is to present alternative key performance indicatorsfor energy usage that can be applied to buildings, and with this report provide KTH andAkademiska Hus with one or more key performance indicators for presenting energy usage inbuildings.

To be able to answer the formulated problem posed in this thesis a description of thework process was worked out. The work process has been divided up into different phases with anumber of specified sub-goals. Phase 1 includes an all-encompassing literature study aboutenergy usage mainly concerning buildings and a general study of energy usage in Sweden. Phase 2is comprised of an interview study and a workshop with the purpose of discussing and makinguse of the concerned parties' experiences in order to come further in the work. Phase 3 includes acase study that will be carried out on two buildings on KTH Campus, V and L houses. Thepurpose with this is to apply the proposed and identified key performance indicators on a realcase and compare both their advantages and disadvantages.

On the basis of phase 1 and 2 the work was limited to focus on analysis of the degree ofutilization and the activities of the buildings on KTH Campus. A model for determination of thedegree of utilization was established on the basis of the room booking system which can yield thenumber of booked hours during a given time period. The total energy usage per square meter forV and L houses is 152,3 and 155,3 kWh per m2 respectively. After the implementation of thedegree of utilization correction in this key performance indicator it can be concluded that thedifference between the two cases increases from 2.0 % to 31.3 %. This means in practice that byanalysis of energy usage in kWh per m2 the difference is very little, while for the case with degreeof utilization correction the difference in energy usage will be clearer. With the new keyperformance indicator with degree of utilization correction, kWh per m2N, the concerned parties,KTH and Akademiska Hus, can even make possible a different energy goal setting in order to,for example, keep certification within the environmental management system, ISO 14001, forwhich one or more energy goals is a precondition.

Furthermore, it can be concluded that Akademiska Hus should provide KTH with data of thevariation in power demand over time in order to more easily be able to identify energy efficiencymeasures and to eventually consider the possibility of installing electricity meters in the buildingsfor mapping energy usage.

Place, publisher, year, edition, pages
2015.
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:kth:diva-160533OAI: oai:DiVA.org:kth-160533DiVA: diva2:790075
Supervisors
Examiners
Available from: 2015-03-05 Created: 2015-02-23 Last updated: 2015-03-05Bibliographically approved

Open Access in DiVA

fulltext(4524 kB)697 downloads
File information
File name FULLTEXT01.pdfFile size 4524 kBChecksum SHA-512
b28ad3d711420edc346e65e6fdb8ef90738c635ee241ce7566e84a21544e09d9e6e6e91509bbaad13657be9b0e1cea7a60ec6ceefff8026d825f60e984218f63
Type fulltextMimetype application/pdf

By organisation
Applied Thermodynamics and Refrigeration
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 697 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1026 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf