Improved confinement in JET high β plasmas with an ITER-like wall
Show others and affiliations
2015 (English)In: Nuclear Fusion, ISSN 0029-5515, E-ISSN 1741-4326, Vol. 55, no 5, 053031Article in journal (Refereed) Published
Abstract [en]

The replacement of the JET carbon wall (C-wall) by a Be/W ITER-like wall (ILW) has affected the plasma energy confinement. To investigate this, experiments have been performed with both the C-wall and ILW to vary the heating power over a wide range for plasmas with different shapes. It was found that the power degradation of thermal energy confinement was weak with the ILW; much weaker than the IPB98(y,2) scaling and resulting in an increase in normalized confinement from H<inf>98</inf> ∼ 0.9 at β<inf>N</inf> ∼ 1.5 to H<inf>98</inf> ∼ 1.2-1.3 at β<inf>N</inf> ∼ 2.5 - 3.0 as the power was increased (where H<inf>98</inf> = τ<inf>E</inf>/τ<inf>IPB98(y,2)</inf> and β<inf>N</inf> = β<inf>T</inf>B<inf>T</inf>/aI<inf>P</inf> in % T/mMA). This reproduces the general trend in JET of higher normalized confinement in the so-called 'hybrid' domain, where normalized β is typically above 2.5, compared with 'baseline' ELMy H-mode plasmas with β<inf>N</inf> ∼ 1.5 - 2.0. This weak power degradation of confinement, which was also seen with the C-wall experiments at low triangularity, is due to both increased edge pedestal pressure and core pressure peaking at high power. By contrast, the high triangularity C-wall plasmas exhibited elevated H<inf>98</inf> over a wide power range with strong, IPB98(y,2)-like, power degradation. This strong power degradation of confinement appears to be linked to an increase in the source of neutral particles from the wall as the power increased, an effect that was not reproduced with the ILW. The reason for the loss of improved confinement domain at low power with the ILW is yet to be clarified, but contributing factors may include changes in the rate of gas injection, wall recycling, plasma composition and radiation. The results presented in this paper show that the choice of wall materials can strongly affect plasma performance, even changing confinement scalings that are relied upon for extrapolation to future devices.

Place, publisher, year, edition, pages
2015. Vol. 55, no 5, 053031
Keyword [en]
neutral particles, plasma confinement, power degradation, wall materials
National Category
Physical Sciences
URN: urn:nbn:se:kth:diva-166940DOI: 10.1088/0029-5515/55/5/053031ISI: 000353546700032ScopusID: 2-s2.0-84928667412OAI: diva2:818514

QC 20150609

Available from: 2015-06-09 Created: 2015-05-21 Last updated: 2015-06-09Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Frassinetti, Lorenzo
By organisation
Fusion Plasma Physics
In the same journal
Nuclear Fusion
Physical Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 18 hits
ReferencesLink to record
Permanent link

Direct link