Abstract [en]

Operating at temperatures well above their melting point, gas turbines' components are subject to terribly high thermal stresses. In order to keep them intact and performing, different cooling techniques are implemented. One of these methods is film cooling. Film cooling implementation in vane cascades has a potential loss expense. Proper assessment of its impact on the vane performance has to be conducted. The CFD approach of modeling each hole and cooling tube autonomously is very computationally expensive. In the current work an assessment of a new, more computationally efficient CFD approach for modelling film cooling was conducted on a vane cascade operating in the transonic regime (M =0.89). The film cooling holes were represented by orifice boundary condition at the vane surface, omitting the need to model internal coolant plenum and cooling tubes mesh, resulting in 180% reduction in grid size and attributed computational cost interpreted in 300% saving in computation time. Uncooled, and film cooled with different configurations and at different blowing ratios (BR) simulations were performed and compared to experimental measurements. A good agreement was obtained for the exit flow angles, vorticity and aerodynamic loss for all the cases (uncooled and cooled). Pitch-averaged exit flow angle outside endwalls regions remains unchanged for all cooling configurations and blowing ratios. The aerodynamic loss was found to be more sensitive to increasing the blowing ratio on the suction side than on the pressure side. The proposed approach of coolant injection modeling is shown to yield reliable results, within the uncertainty of the measurements in most cases. Along with lower computational cost compared to conventional film cooling modeling approach, the new approach is recommended for further analysis for aero and thermal vane cascade flows.

Place, publisher, year, edition, pages
Keyword [en]
Aerodynamics, Computational fluid dynamics, Coolants, Cost benefit analysis, Gas turbines, Transonic aerodynamics, Tubes (components), Uncertainty analysis, Computational costs, Computationally efficient, Coolant injection, Cooling configuration, Cooling technique, Film cooling hole, Reliable results, Transonic annular cascade, Cooling
National Category
Energy Engineering
URN: urn:nbn:se:kth:diva-167519DOI: 10.1115/GT2014-26617ISI: 000361923200040ScopusID: 2-s2.0-84922254911ISBN: 9780791845622OAI: diva2:819722
ASME Turbo Expo 2014: Turbine Technical Conference and Exposition, GT 2014, 16 June 2014 through 20 June 2014

QC 20150611

Available from: 2015-06-11 Created: 2015-05-22 Last updated: 2015-10-29Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Fridh, JensSaha, Ranjan
By organisation
Heat and Power Technology
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 57 hits
ReferencesLink to record
Permanent link

Direct link