Signalförändring i automatisk urinmätare: - en ingående studie om dess orsaker
KTH, School of Technology and Health (STH).
KTH, School of Technology and Health (STH).
2015 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Signal interference in digital urine measurement system : – a detailed study of the causes (English)
Abstract [sv]

Denna rapport diskuterar vilka ämnen i urinen som påverkar förutsättningarna för utvecklingen av biofilm i Observe Medicals automatiska urinmätare Sippi och på så sätt stör mätsignalen. Idéer och förslag på åtgärder mot detta problem diskuteras. Rapporten tar upp fem olika lösningar som har testats med produkten: albumin utspätt med vatten, fritt hemoglobin utspätt med vatten, albumin blandat med urin, fritt hemoglobin blandat med urin samt endast urin. Volymmätningarna gick till på ett sådant sätt att varje lösning pumpades från en behållare till mätkammaren i Sippins engångsset. Alla mätningar utfördes med två varianter av engångsset. I den ena varianten fanns det en silikonolje-kapsel placerad i mätkammaren och i den andra saknades kapseln. Laborationsresultaten visade att albumin ger upphov till fullständig biofilmsutveckling redan efter ett fåtal timmar. Fritt hemoglobin har medfört varierande grad av biofilmsutveckling, beroende på koncentrationen blod i lösningen. Silikonolje-kapseln motverkar effekten av albumin i större grad än fritt hemoglobin. Urin med lågt pH (6,0) visade sig inte ge upphov till biofilm i lika stor utsträckning som urin med högre pH (7,0). Rapporten diskuterar kring det faktum att lågt pH i urinen har en negativ påverkan på förutsättningarna för biofilm, och därmed eventuellt kan användas för att utveckla produkten i framtiden. Rapportens slutsats blev att både albumin och fritt hemoglobin bidrar till utvecklingen av biofilm i Sippi och därmed påverkar mätsignalen.

Abstract [en]

The following report discusses what substances affect the conditions for the formation of biofim in Observe Medicals digital urine measurement system Sippi, and therefore interfere with the measuring signal. Suggestions on how to possibly avoid volume measurement errors are given. The report accounts for five different solutions used during laboratory experiments: albumin mixed with water, free hemoglobin mixed with water, albumin mixed with urine, free hemoglobin mixed with urine, and lastly only urine. During the volume measurements, fluid was pumped from a container to the measurement chamber in the Sippi set. Each measurement was performed twice, with and without a silicon capsule in the chamber. The laboration results showed that albumin develop a complete biofilm after a few hours. Free hemoglobin entailed a varying degree of biofilm development in Sippi, depending on the amount of blood in the solution. The silicon capsule counteracts the effect of albumin to a higher degree than free hemoglobin. Furthermore, urine with low pH (6,0) did not give rise to biofilm to the same extent as urine with high pH (7,0). The report discusses about the fact that low value of pH in urine negatively affects the conditions for formation of biofilm, and may be used to further develop the product in the future. The report concludes that both albumin and free hemoglobin contribute to construction of biofilm in Sippi, and therefore interfere with the signal.

Place, publisher, year, edition, pages
2015. , 20 p.
Series
TRITA-STH, 2015:47
Keyword [sv]
urinmätare, Sippi, signalförändring
National Category
Medical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-170002OAI: oai:DiVA.org:kth-170002DiVA: diva2:826642
External cooperation
Observe Medical
Subject / course
Medical Engineering
Educational program
Master of Science in Engineering - Medical Engineering
Supervisors
Examiners
Available from: 2015-06-27 Created: 2015-06-25 Last updated: 2015-06-27Bibliographically approved

Open Access in DiVA

fulltext(1235 kB)69 downloads
File information
File name FULLTEXT01.pdfFile size 1235 kBChecksum SHA-512
3f5fe8676a0726e8c6554c58cf589695b15def83891b272cd3250a9c09a25e93c7ba60ce24a63ea8448f20a4efa4b162441d929c46cd763df2020aa3e7a3fed5
Type fulltextMimetype application/pdf

By organisation
School of Technology and Health (STH)
Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 69 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 102 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf