Energieffektivisering av bostadsrättsförening
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering.
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering.
2015 (Swedish)Independent thesis Basic level (university diploma), 5 credits / 7,5 HE creditsStudent thesisAlternative title
Energy efficiency of housing association (English)
Abstract [sv]

Den primära uppgiften med studien har varit att undersöka fastigheternas energianvändning och

att undersöka vilka lämpliga effektiviseringsåtgärder som föreningen bör använda i framtida

investeringar.

De åtgärder som undersökts för energieffektivisering är tilläggsisolering på vind, tätning av fönster

och dörrar, byte av fönster, byte av termostatventiler på radiatorer, byte till snålspolande kranar,

mekanisk avgasare till värmesystemet, energidisplayer och tids- och behovsstyrd belysning i

allmänna utrymmen. Dessa åtgärder har bedömts vara de mest lämpliga att undersöka för

föreningen och styrelsen i föreningen kommer att få ta del av studien för att utöka sin kunskap

om passande effektiviseringsåtgärder för framtiden. Då det ofta handlar om stora ekonomiska

investeringar som är sårbart på en liten förening, så har kostnadskalkyler tagits fram på de åtgärder

som varit mest relevanta för föreningen. I studien framkommer det att tilläggsisolering på

vindsutrymmet var den mest fördelaktiga åtgärden som bostadsrättsföreningen kan göra, som har

en kort arbetsåtgång, stor energibesparing och en kort återbetalningstid. En energideklaration har

upprättats för varje separat fastighet eftersom den tidigare deklarationen upprättades 2009 och

känns undermålig. 160kWh/m2 är den nya energiprestandan på Väsman 4 (tidigare 154kWh/m2)

och 145 kWh/m2 är den nya energiprestandan på Skattungen 1 (tidigare 142kWh/m2), en

förändring på 6kWh/m2 respektive 3kWh/m2 från tidigare deklarationen från 2009. Det

försämrade värdet skulle kunna kopplas till många faktorer men några tänkta kan vara slitage på

radiatorer, tätning av fönster och dörrar och att fönsterna idag är i sämre skick. Samt att

fjärrvärmesystemet som installerades när förra deklarationen upprättades, inte fungerar optimalt.

Inga av de rekommenderade åtgärderna från den tidigare energideklarationen var gjorda.

Abstract [en]

The primary task of the study was to investigate the energy consumption of the real estates and to

examine the appropriate measures for the association to take regarding future investments.

The measures investigated for energy efficiency is insulation in the attic, sealing of windows and

doors, replacement of windows, replacement of thermostatic valves on radiators, switching to

low-flow faucets, mechanical degasser to the heating system, energy displays, timing and demand

controlled lighting in public areas. These measures have been deemed the most appropriate to

examine the association and the board of the condominium association will take part of the study

to extend their knowledge of appropriate efficiency measures for the future. As it often involves

large financial investment that is vulnerable to a small association, so the cost estimates have been

developed on the actions that were most relevant for the association. The study shows that adding

insulation to the attic space was the most beneficial action that the condominium association

could make, which takes a short amount of time, saves a large amount of energy and has a short

payback period. An energy performance report have been prepared for each separate real estate

because the previous from 2009 felt inadequate. 160kWh/m2 is the new energy performance on

Väsman 4 (previously 154kWh/m2) and 145 kWh/m2 is the new energy performance on

Skattungen 1 (previously 142kWh/m2). This is an increase of 6kWh/m2 respectively 3kWh/m2

from the prior energy performance report of 2009. The increase of energy consumption could be

linked to many factors, but some possible factors include wear and tear on the radiators,

deteriorated insulation of windows and doors and that the windows today are in worse shape. The

district heating system that was installed when the previous energy performance report was

established is not functioning optimally. None of the recommended actions from the previous

energy performance report has been realised.

Place, publisher, year, edition, pages
2015. , 20 p.
Keyword [en]
energy efficiency, exhaust systems, energy saving, window replacement, mechanical
Keyword [sv]
Energieffektivisering, frånluftssystem, energibesparing, fönsterbyte, fjärrvärme
National Category
Civil Engineering Construction Management
Identifiers
URN: urn:nbn:se:kth:diva-173337OAI: oai:DiVA.org:kth-173337DiVA: diva2:852594
External cooperation
Bostadsrättsföreningen Skattungen 1
Educational program
Higher Education Diploma - Construction Management
Supervisors
Examiners
Available from: 2015-09-24 Created: 2015-09-09 Last updated: 2015-09-24Bibliographically approved

Open Access in DiVA

No full text

By organisation
Civil and Architectural Engineering
Civil EngineeringConstruction Management

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 104 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf