Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Kallkällor i Täby och Vallentuna kommuner – Inventering och vattenkvalitet
KTH, School of Chemical Science and Engineering (CHE).
2015 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Springs in Täby and Vallentuna Municipalites  – Inventory and Water Quality (English)
Abstract [sv]

Vattnet har alltid varit viktigt för människor och andra levande organismer. Förr i tiden var källor viktiga som vattenresurs då dessa ofta har en bra vattenkvalitet på grund av den naturliga reningsprocessen i marken. Källorna är också viktiga biotoper. Källvatten kan användas som dricksvatten och källorna kan ha ett historiskt värde. Därför har en lokalisering av ett tjugotal källor utförts och deras vattenkvalitet har undersökts. Undersökningen gjordes i kommunerna Täby och Vallentuna, där ett fältarbete utfördes och flera parametrar undersöktes både i fält och i laboratorium för att kunna bestämma vattenkvaliteten och jämföra denna med angivna värden i olika föreskrifter om vatten. De parametrar som undersöktes var: flöde, temperatur, pH, konduktivitet, alkalinitet, klorinitet, smak, lukt, färg, lösliga gaser,CODMn, fosfor, svavel samt de vanligaste metallerna med hjälp av ICP-OES. Även en bedömning av geologins betydelse och människans påverkan gjordes.

Totalt sexton källor besöktes, varav alla utom en undersöktes. Samtliga källor hade en normal temperatur för källvatten. Flödet uppskattades eller beräknades till under 0,5 l/s för samtliga källor. pH-värdet låg mellan 6 och 8 i alla källor och alkaliniteten var hög i de flesta av källorna.  Källor med hög alkalinitet hade en hög halt av de vanligaste positiva jonerna natrium, kalium, kalcium och magnesium. I källor med låg alkalinitet förekom järn, mangan och koppar i hög halt. Smak, lukt och färg varierade mycket, från ett gott och kristallklart vatten till ett brunt och illaluktande vatten.  De flesta av källorna hade höga syrehalter och innehöll också mycket koldioxid.  Några källor innehöll mycket klorid,  fosfor och koppar, vilket  indikerar mänsklig påverkan.

Fem av källorna hade en mycket bra vattenkvalitet och dessa utgör fina utflyktsmål. Vattenkvaliteten i dessa källor uppfyllde kraven för dricksvatten. Genom att sätta upp skyltar kan man upplysa almänheten om källornas vattenkvalitet och tradition.

I fem av källorna var vattenkvaliteten däremot dålig och uppfyllde inte kraven för dricksvatten. Några av dessa källor skulle kunna restaureras och vårdas genom att skräp, löv och grenar tas bort. Även  gamla sönderfallna konstruktioner bör avlägsnas.

Abstract [en]

Water has always been important for people and other living organisms. Earlier, when the the springs where important sources of water, the extracted water often had a good quality due to the natural cleansing processes. Furthermore, the springs are important habitats for animals and plants.  Mostly, springwater is excellent drinking water, and may also have a historic value. Therefore, several springs were localised and their water qualities were examined  A survey of  the springs in Täby and Vallentuna municipalities has been made. Relevant water quality parameters were investigated, both in the field and in the laboratory.  The parameters examined were: flow, temperature, pH, conductivity, alkalinity, chlorinity, taste, smell, color, dissolved gases, CODMn, phosphorus, sulfur, and the most common metals with ICP-OES.  Furthermore a survey of the geology and the human impact has been performed.

In total 16 springs were visited, of which all but one were investigated. All springs had a normal temperature of spring water. The flow was estimated or calculated to be under 0,5  l/s in all springs. The pH-values were between six and eight in all springs and the alkalinity was high in most springs. Springs with high alkalinities also had high contents of the dominating positive ions sodium, potassium, calcium and magnesium. In some springs with low alkalinities iron, manganese and copper occurred in high concentrations. Taste, odor and color varied froma  good crystal clear water to a brown and smelly water.  Most of the springs contain high quantities of  oxygen gas and carbon dioxide.  Some springs contained high concentrations of chloride, phosphorus and copper, which indicate a human impact.

Five of the springs have good  water qualities and these springs are excellent goals for excursions.  The water qualities of these springs meet the requirements for drinking water in Sweden. By proper signs at each spring, the public can be informed about the water quality and also about the historical traditions of the spring.  

In five of the springs, the water quality is poor and the water does not satisfy the requirements for the drinking water quality. Some of these springs could be restored and cared for by ceaning away debris, leaves and branches.  Old crumbling structures should also be removed. 

Place, publisher, year, edition, pages
2015.
Keyword [sv]
Kallkällor, Täby, Vallentuna, inventering, vattenkvalitet, geokemi, kolloider, kemiska analyser
National Category
Chemical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-173932OAI: oai:DiVA.org:kth-173932DiVA: diva2:856313
Educational program
Bachelor of Science in Engineering - Chemical Engineering
Available from: 2015-09-23 Created: 2015-09-23 Last updated: 2015-09-23Bibliographically approved

Open Access in DiVA

No full text

By organisation
School of Chemical Science and Engineering (CHE)
Chemical Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 146 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf