Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
En förstudie för utvärdering av en automatisk urinmätare för barn
KTH, School of Technology and Health (STH).
KTH, School of Technology and Health (STH).
2015 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
A pre-study evaluation of an automatic urinometer for children (English)
Abstract [sv]

Urinmätning inom intensivvården är ett viktigt hjälpmedel för att få larm om dysfunktionalitet hos njurarna. Patienters urinproduktion är något som till största delen fortfarande mäts manuellt genom att samla upp urin från urinkatetern ner i en mätbehållare. I rapporten utvärderas en automatisk urinmätare (Sippi®) på en barnintensiv- och barnintermediärvårdsavdelning. Målen med förstudien var att undersöka vilka förbättringar som krävs för att produkten ska vara lämplig att använda på barn samt att ta reda på om Sippi® kan underlätta den fysiska arbetsmiljön och patientkomforten, utan att försämra mätnoggrannheten jämfört med den mätaren som används idag. Detta undersöktes i två delar, intervjuer samt genom kontrollmätningar. Mätnoggrannhetsstudien utfördes genom att den volym som erhölls från respektive mätare kontrollmättes i en mätcylinder. Detta gjordes på 6 patienter där totalt 52 mätningar utfördes med den manuella urinmätaren och 48 med den automatiska. Enligt slutsatsen bör slangen till den automatiska urinmätaren vara kortare än 149 cm men längre än 110 cm. Slangens flöde behöver förbättras och utrustas med en klämma som kan användas för att fästa slangen vid sängen. Angående mätnoggrannheten kunde ingen slutsats dras då signifikanta mätdata saknas.

Abstract [en]

Measuring urine output within the intensive care unit is a helpful tool finding renal dysfunctions. Urine output is a parameter that is in most cases still measured manually, by collecting the urine into a measuring chamber. In this study we have evaluated an automatic device (Sippi®) that measures urine output both at the pediatric intensive care unit and the pediatric intermediate care unit. The aim of the study was to find improvements making Sippi® appropriate for children’s care and to see whether this type of device can ease the work load for the nurses and improve the comfort for patients without having lower accuracy than the manual urinometer used today. The study was divided into two parts, control measurements and interviews. The control measurements compared the value of the urine output given by one of the two urinometers separately with a cylinder measurement. 52 measurements were made with the manual device and 48 with the automatic, altogether collected from six patients. No conclusion could be drawn about the accuracy of the urinometers since the number of data were too few. However from interviews and observations a few enhancements were derived for the automatic urinometer. The hose’s length needs to be shorter than 149 cm but longer than 110 cm, have a better flow and a clamp that allows the hose to be attached to the bed.

Place, publisher, year, edition, pages
2015. , 16 p.
Series
TRITA-STH, 2015:48
Keyword [en]
Automatization, Pediatric intensive care unit, Pediatric intermediate care unit, Urine output, Monitoring, Product development
Keyword [sv]
Automatisering, Barnintensivvårdsavdelning, Barnintermediärvårdsavdelning, Urinproduktion, Övervakning, Produktutveckling
National Category
Medical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-174019OAI: oai:DiVA.org:kth-174019DiVA: diva2:856549
External cooperation
Thoraxkliniken, Karolinska Universitetssjukhuset
Subject / course
Medical Engineering
Educational program
Master of Science in Engineering - Medical Engineering
Supervisors
Examiners
Available from: 2015-09-24 Created: 2015-09-24 Last updated: 2015-09-24Bibliographically approved

Open Access in DiVA

En förstudie för utvärdering av en automatisk urinmätare för barn(879 kB)126 downloads
File information
File name FULLTEXT01.pdfFile size 879 kBChecksum SHA-512
05290f48efdf9f55cb0aa039f2fd4828881ebd9aeaaa247e4c0ec890435bd8d0ea6e049369ed4c9c49831bcecd7750571e7126927dc0847457beebb63baaeb8d
Type fulltextMimetype application/pdf

By organisation
School of Technology and Health (STH)
Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 126 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 94 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf