Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
The Effects of Lowered Delivery Temperatures in District Heating: A Quantitative Study
KTH, School of Industrial Engineering and Management (ITM), Energy Technology, Applied Thermodynamics and Refrigeration.
KTH, School of Industrial Engineering and Management (ITM), Energy Technology, Applied Thermodynamics and Refrigeration.
2015 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesisAlternative title
Effekterna of sänkta framledningstemperaturer i fjärrvärmenätet (Swedish)
Abstract [en]

With development within district heating leading to more incorporation of decentralized production, lowered temperature levels are required to enable these possibilities. Therefore, this study was conducted in collaboration with Fortum with the purpose of investigating and quantifying the effects of lowered delivery temperatures on mass flow and return temperatures. When these effects had been determined, the limiting factors were identified as well as the adjustments needed to enable the lowering delivery temperatures.

This study is divided into two sections: a modeling of four type buildings and two case studies of specific areas of the Stockholm district-heating grid. The two sections of the study both use an Excel constructed model to examine the effects of the new proposed delivery temperature levels. The first section uses four type buildings with varying internal temperature levels to display how different secondary systems react to the changes in delivery temperature. The second section contains two case studies of outer parts of the grid where actual buildings are modeled. In the case studies the pipes speeds and secondary systems are analyzed to determine limiting factors for the lowering of the delivery temperatures.

Overall this study contributes with quantified results of the effects of four lowered delivery temperature profiles on different customer systems. Analysis of the delivery temperatures showed that the largest change was shifting from the actual delivery temperatures of 2011 to the delivery profile that Fortum currently promised to deliver. The pipes of the studied areas were found not to be a limiting factor even in cases where the when mass flows increased three fold. The greatest limiting factor was determined to be the internal temperatures of the buildings, which set a strict limit and cannot be altered by Fortum without the customers’ cooperation.

In conclusion a range of limiting factors were identified that proved to be potential limitations depending on the circumstances of a specific case. Depending on the investment needs in a specific case the economic viability was deemed to most likely be positive. When implementing lowered delivery temperatures in reality it is vital to acquiring data on secondary systems in order to identify the specific limitations of the proposed area. In addition an area of more research on the effects of lowered temperatures on the entirety of the grid as this study only investigates isolated sections. 

Place, publisher, year, edition, pages
2015. , 118 p.
Keyword [en]
District heating, delivery temperatures, Fortum, massflow, heating, domestic heating, district heating grid, open district heating
Keyword [sv]
fjärrvärme, framledningstemperaturer, fortum, massflöde, uppvärmning, öppen fjärrvärme
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:kth:diva-178039OAI: oai:DiVA.org:kth-178039DiVA: diva2:876224
External cooperation
Fortum Värme
Subject / course
Energy Technology
Educational program
Master of Science in Engineering - Industrial Engineering and Management
Presentation
2015-12-25, KTH, Stockhom, 10:00
Supervisors
Examiners
Available from: 2016-01-29 Created: 2015-12-02 Last updated: 2016-01-29Bibliographically approved

Open Access in DiVA

fulltext(16564 kB)119 downloads
File information
File name FULLTEXT01.pdfFile size 16564 kBChecksum SHA-512
2dd95b248057908a12628eaaf72df4558641ee607625321a0561a735afde0dee320f250475ec71a474780e56b945d4e31dc7033038514830473da7fc35d9eaac
Type fulltextMimetype application/pdf

By organisation
Applied Thermodynamics and Refrigeration
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 119 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 151 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf