Change search
ReferencesLink to record
Permanent link

Direct link
Liquid-core nanocellulose-shell capsules with tunable oxygen permeability
KTH, School of Chemical Science and Engineering (CHE), Fibre and Polymer Technology, Polymeric Materials.
KTH, School of Chemical Science and Engineering (CHE), Fibre and Polymer Technology, Polymeric Materials.
Show others and affiliations
2016 (English)In: Carbohydrate Polymers, ISSN 0144-8617, E-ISSN 1879-1344, Vol. 136, 292-299 p.Article in journal (Refereed) Published
Abstract [en]

Encapsulation of oxygen sensitive components is important in several areas, including those in the food and pharmaceutical sectors, in order to improve shelf-life (oxidation resistance). Neat nanocellulose films demonstrate outstanding oxygen barrier properties, and thus nanocellulose-based capsules are interesting from the perspective of enhanced protection from oxygen. Herein, two types of nanocellulose-based capsules with liquid hexadecane cores were successfully prepared; a primary nanocellulose polyurea-urethane capsule (diameter: 1.66 μm) and a bigger aggregate capsule (diameter: 8.3 μm) containing several primary capsules in a nanocellulose matrix. To quantify oxygen permeation through the capsule walls, an oxygen-sensitive spin probe was dissolved within the liquid hexadecane core, allowing non-invasive measurements (spin-probe oximetry, electron spin resonance, ESR) of the oxygen concentration within the core. It was observed that the oxygen uptake rate was significantly reduced for both capsule types compared to a neat hexadecane solution containing the spin-probe, i.e. the slope of the non-steady state part of the ESR-curve was approximately one-third and one-ninth for the primary nanocellulose capsule and aggregated capsule, respectively, compared to that for the hexadecane sample. The transport of oxygen was modeled mathematically and by fitting to the experimental data, the oxygen diffusion coefficients of the capsule wall was determined. These values were, however, lower than expected and one plausible reason for this was that the ESR-technique underestimate the true oxygen uptake rate in the present systems at non-steady conditions, when the overall diffusion of oxygen was very slow.

Place, publisher, year, edition, pages
Elsevier, 2016. Vol. 136, 292-299 p.
National Category
Other Chemistry Topics Polymer Technologies
URN: urn:nbn:se:kth:diva-174572DOI: 10.1016/j.carbpol.2015.09.040ISI: 000365972000037PubMedID: 26572358ScopusID: 2-s2.0-84942278705OAI: diva2:877844

QC 20151208

Available from: 2015-12-08 Created: 2015-10-07 Last updated: 2016-01-19Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMedScopus

Search in DiVA

By author/editor
Hedenqvist, MikaelNilsson, Fritjof
By organisation
Polymeric Materials
In the same journal
Carbohydrate Polymers
Other Chemistry TopicsPolymer Technologies

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 189 hits
ReferencesLink to record
Permanent link

Direct link