Change search
ReferencesLink to record
Permanent link

Direct link
Development of low-dose photon-counting contrast-enhanced tomosynthesis with spectral imaging
-.
-.
-.
Show others and affiliations
2011 (English)In: Radiology, ISSN 0033-8419, Vol. 259, no 2, 558-564 p.Article in journal (Refereed) PublishedText
Abstract [en]

Purpose: To demonstrate the feasibility of low-dose photon-counting tomosynthesis in combination with a contrast agent (contrast material-enhanced tomographic mammography) for the differentiation of breast cancer. Materials and Methods: All studies were approved by the institutional review board, and all patients provided written informed consent. A phantom model with wells of iodinated contrast material (3 mg of iodine per milliliter) 1, 2, 5, 10, and 15 mm in diameter was assessed. Nine patients with malignant lesions and one with a high-risk lesion (atypical papilloma) were included (all women; mean age, 60 7 years). A multislit photon-counting tomosynthesis system was utilized (spectral imaging) to produce both low- and high-energy tomographic data (below and above the k edge of iodine, respectively ) in a single scan, which allowed for dual-energy visualization of iodine. Images were obtained prior to contrast material administration and 120 and 480 seconds after contrast material administration. Four readers independently assessed the images along with conventional mammograms, ultrasonographic images, and magnetic resonance images. Glandular dose was estimated. Results: Contrast agent was visible in the phantom model with simulated spherical tumor diameters as small as 5 mm. The average glandular dose was measured as 0.42 mGy per complete spectral imaging tomosynthesis scan of one breast. Because there were three time points (prior to contrast medium administration and 120 and 480 seconds after contrast medium administration), this resulted in a total dose of 1.26 mGy for the whole procedure in the breast with the abnormality. Seven of 10 cases were categorized as Breast Imaging Reporting and Data System score of 4 or higher by all four readers when reviewing spectral images in combination with mammograms. One lesion near the chest wall was not captured on the spectral image because of a positioning problem. Conclusion: The use of contrast-enhanced tomographic mammography has been demonstrated successfully in patients with promising diagnostic benefit. Further studies are necessary to fully assess diagnostic sensitivity and specificity.

Place, publisher, year, edition, pages
RADIOLOGICAL SOC NORTH AMERICA , 2011. Vol. 259, no 2, 558-564 p.
Keyword [en]
Photo counting tomosynthesis spectrial imaging
National Category
Radiology, Nuclear Medicine and Medical Imaging
Research subject
Medical Technology; Physics
Identifiers
URN: urn:nbn:se:kth:diva-186032DOI: 10.1148/radiol.11101682ISI: 000289667300031PubMedID: 21330558ScopusID: 2-s2.0-79955001992OAI: oai:DiVA.org:kth-186032DiVA: diva2:924988
Conference
-
Projects
-
Note

QC 20160512

Available from: 2016-04-29 Created: 2016-04-29 Last updated: 2016-05-31Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMedScopus

Search in DiVA

By author/editor
Danielsson, Mats
By organisation
Physics of Medical Imaging
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 7 hits
ReferencesLink to record
Permanent link