Change search
ReferencesLink to record
Permanent link

Direct link
Accuracy and Precision of Three-Dimensional Low Dose CT Compared to Standard RSA in Acetabular Cups: An Experimental Study
Department of Molecular Medicine and Surgery, Karolinska Institutet.ORCID iD: 0000-0002-9801-2733
Department of Molecular Medicine and Surgery, Karolinska Institutet.
KTH, School of Information and Communication Technology (ICT), Communication Systems, CoS, Radio Systems Laboratory (RS Lab).ORCID iD: 0000-0002-6066-746X
New York University, Department of Radiology.ORCID iD: 0000-0002-2442-1622
Show others and affiliations
2016 (English)In: BioMed Research International, ISSN 2314-6133, E-ISSN 2314-6141, 5909741Article in journal (Refereed) Published
Abstract [en]

Background and Purpose. The gold standard for detection of implant wear and migration is currently radiostereometry (RSA). The purpose of this study is to compare a three-dimensional computed tomography technique (3D CT) to standard RSA as an alternative technique for measuring migration of acetabular cups in total hip arthroplasty.

Materials and Methods. With tantalum beads, we marked one cemented and one uncemented cup and mounted these on a similarly marked pelvic model. A comparison was made between 3D CT and standard RSA for measuring migration. Twelve repeated stereoradiographs and CT scans with double examinations in each position and gradual migration of the implants were made. Precision and accuracy of the 3D CT were calculated.

Results. The accuracy of the 3D CT ranged between 0.07 and 0.32 mm for translations and 0.21 and 0.82° for rotation. The precision ranged between 0.01 and 0.09 mm for translations and 0.06 and 0.29° for rotations, respectively. For standard RSA, the precision ranged between 0.04 and 0.09 mm for translations and 0.08 and 0.32° for rotations, respectively. There was no significant difference in precision between 3D CT and standard RSA. The effective radiation dose of the 3D CT method, comparable to RSA, was estimated to be 0.33 mSv.

Interpretation. Low dose 3D CT is a comparable method to standard RSA in an experimental setting.

Place, publisher, year, edition, pages
Hindawi Publishing Corporation, 2016. 5909741
National Category
Orthopedics Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:kth:diva-189725DOI: 10.1155/2016/5909741OAI: oai:DiVA.org:kth-189725DiVA: diva2:948397
Available from: 2016-07-11 Created: 2016-07-11 Last updated: 2016-07-12Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPublished version

Search in DiVA

By author/editor
Brodén, CyrusMaguire Jr., Gerald Q.Noz, Marilyn E.Zeleznik, Michael P.Sköldenberg, Olof
By organisation
Radio Systems Laboratory (RS Lab)
In the same journal
BioMed Research International
OrthopedicsRadiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 31 hits
ReferencesLink to record
Permanent link

Direct link