Abstract [en]

Electricity grids worldwide are continuing to be severely constrained and stretched to capacity. Certain grid conditions e.g., peak load crisis or loss of generation may lead to severe under frequency situations. Load shedding can then be useful to prevent the national grid from being overwhelmed. Typically, load shedding is done from medium voltage substation level and all customers including emergency service providers under that substation lose power. However, it is beneficial for a society to exclude emergency service providers from load shedding. Smart Meters (SMs) are generally equipped with remotely accessible switch which gives a unique opportunity to exclude prioritized customers during emergency load shedding. Distribution System Operators (DSOs) are currently using remote SM switching typically for one customer at a time. However, the SM switching technique has not been fully investigated with regard to multiple customers. In order to fulfill the gap, this paper presents results obtained from field tests on simultaneous multiple SMs switching with a main focus on the impact of multiple SMs switching on Power Quality (PQ). The results show that impact on PQ might be negligible for small number of SMs switching. Moreover, faster SMs switching and reliable communication system is found as an important prerequisite to use SMs for emergency load shedding.

Place, publisher, year, edition, pages
2015. 7387158
Keyword [en]
Electrical Distribution System, Power Quality, Remote Switching, Smart Grid, Smart Meter
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:kth:diva-192053DOI: 10.1109/ISGT-Asia.2015.7387158ISI: 000380445100199Scopus ID: 2-s2.0-84964938411ISBN: 978-1-5090-1237-4 (print)OAI: oai:DiVA.org:kth-192053DiVA: diva2:963017
Conference
IEEE Innovative Smart Grid Technologies - Asia (ISGT ASIA 2015), NOV 03-06, 2015, Bangkok, THAILAND
Note

QC 20160907

Available from: 2016-09-07 Created: 2016-09-05 Last updated: 2016-09-07Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Bertling Tjernberg, Lina
By organisation
Electromagnetic Engineering
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

Altmetric score

Total: 14 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf