Endre søk
Begrens søket
1234567 1 - 50 of 625
RefereraExporteraLink til resultatlisten
Permanent link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Treff pr side
  • 5
  • 10
  • 20
  • 50
  • 100
  • 250
Sortering
  • Standard (Relevans)
  • Forfatter A-Ø
  • Forfatter Ø-A
  • Tittel A-Ø
  • Tittel Ø-A
  • Type publikasjon A-Ø
  • Type publikasjon Ø-A
  • Eldste først
  • Nyeste først
  • Skapad (Eldste først)
  • Skapad (Nyeste først)
  • Senast uppdaterad (Eldste først)
  • Senast uppdaterad (Nyeste først)
  • Disputationsdatum (tidligste først)
  • Disputationsdatum (siste først)
  • Standard (Relevans)
  • Forfatter A-Ø
  • Forfatter Ø-A
  • Tittel A-Ø
  • Tittel Ø-A
  • Type publikasjon A-Ø
  • Type publikasjon Ø-A
  • Eldste først
  • Nyeste først
  • Skapad (Eldste først)
  • Skapad (Nyeste først)
  • Senast uppdaterad (Eldste først)
  • Senast uppdaterad (Nyeste først)
  • Disputationsdatum (tidligste først)
  • Disputationsdatum (siste først)
Merk
Maxantalet träffar du kan exportera från sökgränssnittet är 250. Vid större uttag använd dig av utsökningar.
  • 1.
    Abtahi, Farhad
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Aspects of Electrical Bioimpedance Spectrum Estimation2014Licentiatavhandling, med artikler (Annet vitenskapelig)
    Abstract [en]

    Electrical bioimpedance spectroscopy (EBIS) has been used to assess the status or composition of various types of tissue, and examples of EBIS include body composition analysis (BCA) and tissue characterisation for skin cancer detection. EBIS is a non-invasive method that has the potential to provide a large amount of information for diagnosis or monitoring purposes, such as the monitoring of pulmonary oedema, i.e., fluid accumulation in the lungs. However, in many cases, systems based on EBIS have not become generally accepted in clinical practice. Possible reasons behind the low acceptance of EBIS could involve inaccurate models; artefacts, such as those from movements; measurement errors; and estimation errors. Previous thoracic EBIS measurements aimed at pulmonary oedema have shown some uncertainties in their results, making it difficult to produce trustworthy monitoring methods. The current research hypothesis was that these uncertainties mostly originate from estimation errors. In particular, time-varying behaviours of the thorax, e.g., respiratory and cardiac activity, can cause estimation errors, which make it tricky to detect the slowly varying behaviour of this system, i.e., pulmonary oedema.

    The aim of this thesis is to investigate potential sources of estimation error in transthoracic impedance spectroscopy (TIS) for pulmonary oedema detection and to propose methods to prevent or compensate for these errors.   This work is mainly focused on two aspects of impedance spectrum estimation: first, the problems associated with the delay between estimations of spectrum samples in the frequency-sweep technique and second, the influence of undersampling (a result of impedance estimation times) when estimating an EBIS spectrum. The delay between frequency sweeps can produce huge errors when analysing EBIS spectra, but its effect decreases with averaging or low-pass filtering, which is a common and simple method for monitoring the time-invariant behaviour of a system. The results show the importance of the undersampling effect as the main estimation error that can cause uncertainty in TIS measurements.  The best time for dealing with this error is during the design process, when the system can be designed to avoid this error or with the possibility to compensate for the error during analysis. A case study of monitoring pulmonary oedema is used to assess the effect of these two estimation errors. However, the results can be generalised to any case for identifying the slowly varying behaviour of physiological systems that also display higher frequency variations.  Finally, some suggestions for designing an EBIS measurement system and analysis methods to avoid or compensate for these estimation errors are discussed.

  • 2.
    Abtahi, Farhad
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Towards Heart Rate Variability Tools in P-Health: Pervasive, Preventive, Predictive and Personalized2016Doktoravhandling, med artikler (Annet vitenskapelig)
    Abstract [en]

    Heart rate variability (HRV) has received much attention lately. It has been shown that HRV can be used to monitor the autonomic nervous system and to detect autonomic dysfunction, especially vagal dysfunction. Reduced HRV is associated with several diseases and has also been suggested as a predictor of poor outcomes and sudden cardiac death. HRV is, however, not yet widely accepted as a clinical tool and is mostly used for research. Advances in neuroimmunity with an improved understanding of the link between the nervous and immune systems have opened a new potential arena for HRV applications. An example is when systemic inflammation and autoimmune disease are primarily caused by low vagal activity; it can be detected and prognosticated by reduced HRV. This thesis is the result of several technical development steps and exploratory research where HRV is applied as a prognostic diagnostic tool with preventive potential. The main objectives were 1) to develop an affordable tool for the effective analysis of HRV, 2) to study the correlation between HRV and pro-inflammatory markers and the potential degree of activity in the cholinergic anti-inflammatory pathway, and 3) to develop a biofeedback application intended for support of personal capability to increase the vagal activity as reflected in increased HRV. Written as a compilation thesis, the methodology and the results of each study are presented in each appended paper. In the thesis frame/summary chapter, a summary of each of the included papers is presented, grouped by topic and with their connections. The summary of the results shows that the developed tools may accurately register and properly analyse and potentially influence HRV through the designed biofeedback game. HRV can be used as a prognostic tool, not just in traditional healthcare with a focus on illness but also in wellness. By using these tools for the early detection of decreased HRV, prompt intervention may be possible, enabling the prevention of disease. Gamification and serious gaming is a potential platform to motivate people to follow a routine of exercise that might, through biofeedback, improve HRV and thereby health.

  • 3.
    Abtahi, Farhad
    et al.
    KTH, Skolan för teknik och hälsa (STH). Karolinska Institute, Sweden.
    Anund, A.
    Fors, C.
    Seoane, Fernando
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik. Karolinska Institute, Sweden.
    Lindecrantz, Kaj
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik. Karolinska Institute, Sweden.
    Association of drivers’ sleepiness with heart rate variability: A pilot study with drivers on real roads2017Inngår i: EMBEC & NBC 2017, Springer, 2017, Vol. 65, s. 149-152Konferansepaper (Fagfellevurdert)
    Abstract [en]

    Vehicle crashes lead to huge economic and social consequences, and one non-negligible cause of accident is driver sleepiness. Driver sleepiness analysis based on the monitoring of vehicle acceleration, steering and deviation from the road or physiological and behavioral monitoring of the driver, e.g., monitoring of yawning, head pose, eye blinks and eye closures, electroencephalogram, electrooculogram, electromyogram and electrocardiogram (ECG), have been used as a part of sleepiness alert systems. Heart rate variability (HRV) is a potential method for monitoring of driver sleepiness. Despite previous positive reports from the use of HRV for sleepiness detection, results are often inconsistent between studies. In this work, we have re-evaluated the feasibility of using HRV for detecting drivers’ sleepiness during real road driving. A database consists of ECG measurements from 10 drivers, driving during morning, afternoon and night sessions on real road were used. Drivers have reported their average sleepiness level by using the Karolinska sleepiness scale once every five minutes. Statistical analysis was performed to evaluate the potential of HRV indexes to distinguish between alert, first signs of sleepiness and severe sleepiness states. The results suggest that individual subjects show different reactions to sleepiness, which produces an individual change in HRV indicators. The results motivate future work for more personalized approaches in sleepiness detection.

  • 4.
    Abtahi, Farhad
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Berndtsson, Andreas
    Abtahi, Shirin
    Seoane, Fernando
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Lindecrantz, Kaj
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Development and preliminary evaluation of an Android based heart rate variability biofeedback system2014Inngår i: Engineering in Medicine and Biology Society (EMBC), 2014 36th Annual International Conference of the IEEE, IEEE conference proceedings, 2014, s. 3382-3385Konferansepaper (Fagfellevurdert)
    Abstract [en]

    The reduced Heart Rate Variability (HRV) is believed to be associated with several diseases such as congestive heart failure, diabetes and chronic kidney diseases (CKD). In these cases, HRV biofeedback may be a potential intervention method to increase HRV which in turn is beneficial to these patients. In this work, a real-time Android biofeedback application based on a Bluetooth enabled ECG and thoracic electrical bioimpedance (respiration) measurement device has been developed. The system performance and usability have been evaluated in a brief study with eight healthy volunteers. The result demonstrates real-time performance of system and positive effects of biofeedback training session by increased HRV and reduced heart rate. Further development of the application and training protocol is ongoing to investigate duration of training session to find an optimum length and interval of biofeedback sessions to use in potential interventions.

  • 5.
    Abtahi, Farhad
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system. Karolinska Institutet, Sweden.
    Hilderman, Marie
    Bruchfeld, Annette
    Seoane, Fernando
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system. University of Borås, Sweden.
    Janerot-Sjöberg, Birgitta
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinsk bildteknik. Karolinska Institutet, Sweden.
    Lindecrantz, Kaj
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system. Karolinska Institutet, Sweden.
    Pro-inflammatory Blood Markers and Heart Rate Variability in Apnoea as a Reflection of Basal Vagal ToneManuskript (preprint) (Annet vitenskapelig)
    Abstract [en]

    Pro-inflammatory cytokines play a crucial role in inflammatory response, which istightly regulated by the nervous system to avoid the damage caused by inflammation. There isevidence for a cholinergic anti-inflammatory pathway that includes afferent and efferent vagalnerves that sense the inflammation and stimulate the anti-inflammatory response. Non-functionalanti-inflammatory response might lead to excessive and chronic inflammation e.g., rheumatoidarthritis (RA), inflammatory bowel disease (IBD), and poor outcome. Heart rate variability(HRV) has been proposed as a potential tool to monitor the level of anti-inflammatory activitythrough the monitoring of vagal activity. In this paper, the association of pro-inflammatorymarkers with HRV indices is evaluated. We used a database called “Heart Biomarker Evaluationin Apnea Treatment (HeartBEAT)” that consists of 6±2 hours of Electrocardiogram (ECG)recordings during nocturnal sleep from 318 patients at baseline and 301of them at 3 monthsfollow-up. HRV indices are calculated from ECG recordings of 5-360 minutes. The results showa statistically significant correlation between heart rate (HR) and pro-inflammatory cytokines,independent of duration of ECG analysis. HRV indices e.g., standard deviation of all RRintervals (SDNN) show an inverse relation to the pro-inflammatory cytokines. Longer ECGrecordings show a higher potential to reflect the level of anti-inflammatory response. In light oftheories for the cholinergic anti-inflammatory pathway, a combination of HR and HRV as areflection of basal vagal activity might be a potential prognostic tool for interventional guidance.

  • 6.
    Abtahi, Farhad
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Ji, Guangchao
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Lu, Ke
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Rodby, Kristian
    Seoane, Fernando
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    A knitted garment using intarsia technique for Heart Rate Variability biofeedback: Evaluation of initial prototype2015Inngår i: Engineering in Medicine and Biology Society (EMBC), 2015 37th Annual International Conference of the IEEE, IEEE , 2015, Vol. 2015, s. 3121-3124Konferansepaper (Fagfellevurdert)
    Abstract [en]

    Heart rate variability (HRV) biofeedback is a method based on paced breathing at specific rate called resonance frequency by giving online feedbacks from user respiration and its effect on HRV. Since the HRV is also influence by different factors like stress and emotions, stress related to an unfamiliar measurement device, cables and skin electrodes may cover the underling effect of such kind of intervention. Wearable systems are usually considered as intuitive solutions which are more familiar to the end-user and can help to improve usability and hence reducing the stress. In this work, a prototype of a knitted garment using intarsia technique is developed and evaluated. Results show the satisfactory level of quality for Electrocardiogram and thoracic electrical bioimpedance i.e. for respiration monitoring as a part of HRV biofeedback system. Using intarsia technique and conductive yarn for making the connection instead of cables will reduce the complexity of fabrication in textile production and hence reduce the final costs in a final commercial product. Further development of garment and Android application is ongoing and usability and efficiency of final prototype will be evaluated in detail.

  • 7.
    Abtahi, Farhad
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Ji, Guangchao
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Lu, Ke
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Rödby, Kristian
    Högskolan i Borås, Akademin för textil, teknik och ekonomi.
    Björlin, Anders
    Kiwok AB.
    Östlund, Anders
    Kiwok AB.
    Seoane, Fernando
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system. Högskolan i Borås, Akademin för vård, arbetsliv och välfärd.
    Lindecrantz, Kaj
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Textile-Electronic Integration in Wearable Measurement Garments for Pervasive Healthcare Monitoring2015Konferansepaper (Annet vitenskapelig)
  • 8.
    Abtahi, Farhad
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Lindecrantz, Kaj
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Seoane, Fernando
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Aslamy, Benjamin
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Boujabir, Imaneh
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    An Affordable ECG and Respiration Monitoring System Based on Raspberry PI and ADAS1000: First Step towards Homecare Applications2015Inngår i: 16th Nordic-Baltic Conference on Biomedical Engineering: 16. NBC & 10. MTD 2014 joint conferences. October 14-16, 2014, Gothenburg, Sweden, Springer, 2015, s. 5-8Konferansepaper (Fagfellevurdert)
    Abstract [en]

    Homecare is a potential solution for problems associated with an aging population. This may involve several physiological measurements, and hence a flexible but affordable measurement device is needed. In this work, we have designed an ADAS1000-based four-lead electrocardiogram (ECG) and respiration monitoring system. It has been implemented using Raspberry PI as a platform for homecare applications. ADuM chips based on iCoupler technology have been used to achieve electrical isolation as required by IEC 60601 and IEC 60950 for patient safety. The result proved the potential of Raspberry PI for the design of a compact, affordable, and medically safe measurement device. Further work involves developing a more flexible software for collecting measurements from different devices (measuring, e.g., blood pressure, weight, impedance spectroscopy, blood glucose) through Bluetooth or user input and integrating them into a cloud-based homecare system.

  • 9.
    Abtahi, Farhad
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Lu, Ke
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Dizon, M
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Johansson, M
    KTH-School of Technology and Health.
    Seoane, Fernando
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system. Högskolan i Borås.
    Lindecrantz, Kaj
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik. Högskolan i Borås, Akademin för vård, arbetsliv och välfärd.
    Evaluating Atrial Fibrillation Detection Algorithm based on Heart Rate Variability analysis2015Inngår i: Medicinteknikdagarna, Uppsala: Svensk förening för medicinsk teknik och fysik , 2015Konferansepaper (Fagfellevurdert)
  • 10.
    Abtahi, Farhad
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Lu, Ke
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Dizon, M
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Johansson, M
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Seoane, Fernando
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system. Högskolan i Borås, Akademin för vård, arbetsliv och välfärd.
    Lindecrantz, Kaj
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Evaluation of Atrial Fibrillation Detection by using Heart Rate Variability analysis2015Konferansepaper (Annet vitenskapelig)
  • 11.
    Abtahi, Farhad
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Lu, Ke
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Guangchao, Li
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Rödby, Kristian
    Högskolan i Borås, Akademin för textil, teknik och ekonomi.
    Seoane, Fernando
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system. Högskolan i Borås.
    A Knitted Garment using Intarsia Technique for Heart Rate Variability Biofeedback: Evaluation of Initial Prototype.2015Konferansepaper (Annet vitenskapelig)
  • 12.
    Abtahi, Farhad
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Seoane, Fernando
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Lindecrantz, Kaj
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Electrical bioimpedance spectroscopy in time-variant systems: Is undersampling always a problem?2014Inngår i: Journal of Electrical Bioimpedance, ISSN 1891-5469, Vol. 5, nr 1, s. 28-33Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    During the last decades, Electrical Bioimpedance Spectroscopy (EBIS) has been applied mainly by using the frequency-sweep technique, across a range of many different applications. Traditionally, the tissue under study is considered to be time-invariant and dynamic changes of tissue activity are ignored by treating the changes as a noise source. A new trend in EBIS is simultaneous electrical stimulation with several frequencies, through the application of a multi-sine, rectangular or other waveform. This method can provide measurements fast enough to sample dynamic changes of different tissues, such as cardiac muscle. This high sampling rate comes at a price of reduction in SNR and the increase in complexity of devices. Although the frequency-sweep technique is often inadequate for monitoring the dynamic changes in a variant system, it can be used successfully in applications focused on the time-invariant or slowly-variant part of a system. However, in order to successfully use frequency-sweep EBIS for monitoring time-variant systems, it is paramount to consider the effects of aliasing and especially the folding of higher frequencies, on the desired frequency e.g. DC level. This paper discusses sub-Nyquist sampling of thoracic EBIS measurements and its application in the case of monitoring pulmonary oedema. It is concluded that by considering aliasing, and with proper implementation of smoothing filters, as well as by using random sampling, frequency-sweep EBIS can be used for assessing time-invariant or slowly-variant properties of time-variant biological systems, even in the presence of aliasing. In general, undersampling is not always a problem, but does always require proper consideration.

  • 13.
    Abtahi, Farhad
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Seoane, Fernando
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Lindecrantz, Kaj
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Löfgren, Nils
    Elimination of ECG Artefacts in Foetal EEG Using Ensemble Average Subtraction and Wavelet Denoising Methods: A Simulation2014Inngår i: XIII Mediterranean Conference on Medical and Biological Engineering and Computing 2013, Springer, 2014, s. 551-554Konferansepaper (Fagfellevurdert)
    Abstract [en]

    Biological signals recorded from surface electrodes contain interference from other signals which are not desired and should be considered as noise. Heart activity is especially present in EEG and EMG recordings as a noise. In this work, two ECG elimination methods are implemented; ensemble average subtraction (EAS) and wavelet denoising methods. Comparison of these methods has been done by use of simulated signals achieved by adding ECG to neonates EEG. The result shows successful elimination of ECG artifacts by using both methods. In general EAS method which remove estimate of all ECG components from signal is more trustable but it is also harder for implementation due to sensitivity to noise. It is also concluded that EAS behaves like a high-pass filter while wavelet denoising method acts as low-pass filter and hence the choice of one method depends on application.

  • 14.
    Abtahi, Farhad
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Snäll, Jonatan
    KTH, Skolan för teknik och hälsa (STH).
    Aslamy, Benjamin
    KTH, Skolan för teknik och hälsa (STH).
    Abtahi, Shirin
    KTH, Skolan för teknik och hälsa (STH).
    Seoane, Fernando
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system. University of Boras, Sweden.
    Lindecrantz, Kaj
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system. Karolinska Institute, Sweden.
    Biosignal PI, an Affordable Open-Source ECG and Respiration Measurement System2014Inngår i: Sensors, ISSN 1424-8220, E-ISSN 1424-8220, Vol. 15, nr 1, s. 93-109Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Bioimedical pilot projects e.g., telemedicine, homecare, animal and human trials usually involve several physiological measurements. Technical development of these projects is time consuming and in particular costly. A versatile but affordable biosignal measurement platform can help to reduce time and risk while keeping the focus on the important goal and making an efficient use of resources. In this work, an affordable and open source platform for development of physiological signals is proposed. As a first step an 8–12 leads electrocardiogram (ECG) and respiration monitoring system is developed. Chips based on iCoupler technology have been used to achieve electrical isolation as required by IEC 60601 for patient safety. The result shows the potential of this platform as a base for prototyping compact, affordable, and medically safe measurement systems. Further work involves both hardware and software development to develop modules. These modules may require development of front-ends for other biosignals or just collect data wirelessly from different devices e.g., blood pressure, weight, bioimpedance spectrum, blood glucose, e.g., through Bluetooth. All design and development documents, files and source codes will be available for non-commercial use through project website, BiosignalPI.org.

  • 15.
    Ahmady, Tobias
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    Klein Rosmar, Sander
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    Translation of keywords between English and Swedish2014Independent thesis Basic level (university diploma), 10 poäng / 15 hpOppgave
    Abstract [en]

    In this project, we have investigated how to perform rule-based machine translation of sets of keywords between two languages. The goal was to translate an input set, which contains one or more keywords in a source language, to a corresponding set of keywords, with the same number of elements, in the target language. However, some words in the source language may have several senses and may be translated to several, or no, words in the target language. If ambiguous translations occur, the best translation of the keyword should be chosen with respect to the context. In traditional machine translation, a word's context is determined by a phrase or sentences where the word occurs. In this project, the set of keywords represents the context.

    By investigating traditional approaches to machine translation (MT), we designed and described models for the specific purpose of keyword- translation. We have proposed a solution, based on direct translation for translating keywords between English and Swedish. In the proposed solu- tion, we also introduced a simple graph-based model for solving ambigu- ous translations. 

  • 16.
    Ahmed, Tanvir Saif
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    Markovic, Bratislav
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    Distribuerade datalagringssystem för tjänsteleverantörer: Undersökning av olika användningsfall för distribuerade datalagringssystem2016Independent thesis Basic level (university diploma), 10 poäng / 15 hpOppgave
    Abstract [sv]

    Detta examensarbete handlar om undersökning av tre olika användningsfall inom datalagring; Cold Storage, High Performance Storage och Virtual Machine Storage. Rapporten har som syfte att ge en översikt över kommersiella distribuerade filsystem samt en djupare undersökning av distribuerade filsystem som bygger på öppen källkod och därmed hitta en optimal lösning för dessa användnings-fall. I undersökningen ingick att analysera och jämföra tidigare arbeten där jämförelser mellan pre-standamätningar, dataskydd och kostnader utfördes samt lyfta upp diverse funktionaliteter (snapshotting, multi-tenancy, datadeduplicering, datareplikering) som moderna distribuerade filsy-stem kännetecknas av. Både kommersiella och öppna distribuerade filsystem undersöktes. Även en kostnadsuppskattning för kommersiella och öppna distribuerade filsystem gjordes för att ta reda på lönsamheten för dessa två typer av distribuerat filsystem.Efter att jämförelse och analys av olika tidigare arbeten utfördes, visade sig att det öppna distribue-rade filsystemet Ceph lämpade sig bra som en lösning utifrån kraven som sattes som mål för High Performance Storage och Virtual Machine Storage. Kostnadsuppskattningen visade att det var mer lönsamt att implementera ett öppet distribuerat filsystem. Denna undersökning kan användas som en vägledning vid val mellan olika distribuerade filsystem.

  • 17.
    Alameddine, Raged
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    Dashtbozorg, Sajad
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    Utredning av för- och nackdelar med TN-S respektive TN-C system2016Independent thesis Basic level (university diploma), 10 poäng / 15 hpOppgave
    Abstract [sv]

    I denna rapport analyseras för- och nackdelar med eldistributionssystem av typ TN-C (fyrledarsystem) respektive TN-S (femledarsystem) system. Det finns olika uppfattningar om vilket system som är lämpligast att bygga ut i distributionsnätet (lågspänningsnätet) och i fastigheternas huvudledning. Med hjälp av litteraturstudier och kontakt med olika elföretag och elbolag har olika ståndpunkter diskuterats och därefter har en sammanställning av resultatet tagits fram. Enligt analysen är TN-C det lämpligaste alternativet att använda i distributionsnätet och TN-S bör användas i fastighetens huvudledning. Detta för att kunna uppnå en god och stabil elmiljö. Detta examensarbete skall underlätta val av teknik och förhoppningsvis öka kunskapen angående ämnet. 

  • 18.
    Al-Battat, Ahmed
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    Anwer, Noora
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    Utvärdering utifrån ett mjukvaruutveckling perspektiv av ramverk för SharePoint2017Independent thesis Basic level (university diploma), 10 poäng / 15 hpOppgave
    Abstract [sv]

    Inom ett företag eller en organisation finns det stor nytta av intranät som ett arbetsverktyg för att kunna dela information. Ett välfungerat intranät bidrar till ett bättre informationsflöde och ett effektivare samarbete. SharePoint är en plattform för intranät med interaktiva funktioner. Omnia är ett ramverk anpassad för Microsofts SharePoint 2013.I detta arbete undersöks hur Omnia fungerar som ett ramverk och vad produkten lämpar sig för. Omnia ramverket utvärderades noggrant och en oberoende bedömning utfördes under examensarbetet. Utvärderingen var baserad på vetenskapliga undersökningar som byggde på den kvalitativa och kvantitativa forskningsmetodiken. Utvärderingens huvudområden baserades på systemets prestanda, skalbarhet, arkitektur och funktionalitet. En testprototyp utvecklades under arbetets gång genom Omnia i from av en webbaserad applikation.Ramverket Omnia var lämplig för utveckling av interaktiva webbaserade applikationer för intranät i SharePoint. Dock saknade den färdig dokumentation/API, vilket gjorde utvecklingsprocessen mer avancerad. Lösningsarkitekturen för systemet uppfyllde kraven för skalbara system, eftersom den baserades på lagerarkitektur. Systemet hade även bra prestanda, dock försämrades den efter att antalet användare översteg ettusen. Funktionaliteten testades med hjälp av två olika tester, vilket visade att produkten är lämplig för att användas i intranät.

  • 19.
    Ali, Abdi
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    START AND STOP COSTS FOR SECONDARY REGULATION OF FORTUM HYDROPOWER PLANTS2015Independent thesis Basic level (university diploma), 10 poäng / 15 hpOppgave
    Abstract [en]

    Kopiera in engelskt abstract från rapporten.

  • 20.
    Al-Qaysi, Bashar
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    Björk, Sara
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    Evaluation of tools for automatedacceptance testing of webapplications2016Independent thesis Basic level (professional degree), 10 poäng / 15 hpOppgave
    Abstract [en]

    Auddly provides a music management tool that gathers all information about a musical piece in oneplace. The acceptance testing on their web application is done manually, which has become bothtime and money consuming. To solve this problem, an evaluation on automated acceptance testingwas done to find a testing tool suitable for their web application. The evaluation was performed byfinding the current existing testing strategies to later compare the tools implementing these strategies.When analyzing the results it was found that two testing strategies were best suited for automatedacceptance testing. The Visual Recognition strategy that identifies components using screenshotsand the Record and Replay strategy that identifies them by their underlying ID. The choice betweenthem depends on which of these properties are modified more often.It was also found that automating acceptance testing is best applied for regression testing, otherwiseit should be performed with a manual approach.It was made clear that the Selenium tool, which uses the Record and Replay strategy, was best suitedfor Auddly’s acceptance testing. Selenium is able to test AJAX-calls with a manual modificationand is a free and open source tool with a large community.

  • 21.
    Alsén, Caroline
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    Kostnadsfördelar med IoT för hissystem2016Independent thesis Basic level (professional degree), 10 poäng / 15 hpOppgave
    Abstract [sv]

    Internet of things är idag en utveckling som starkt går framåt för att göra samhället mer tekniskt styrt, modernt och för att underlätta för människor. Det finns många branscher och arbetsområden för denna teknik och hissbranschen är en utav dessa. I denna rapport utreds de fördelar som finns med Internet of things inom hissövervakning. Företaget Safeline Sweden AB har tagit fram en produkt för att underlätta övervakningen av hissar på avstånd. En utredning av denna produkt och dess kostnadsfördelar togs fram, för att sedan kunna ta fram en affärsmodell för Safelines nya produkt IMS. Genom intervjuer med potentiella kunder kunde information tas fram angående dagens läge inställningen till ny teknik. Den informationen som kom fram under dessa intervjuer användes för att skapa en affärsmodell som ska användas som grund för en affärplan för Safeline.En affärsmodell skapades för Safeline Sweden AB och deras nya produkt IMS. I affärmodellen framgår det bland annat hur företaget bör lansera den nya produkten, hur kundrelationer ska skapas, utvecklas och behållas. Utifrån intervjuerna valdes det att IMS bör säljas som en systemlösning då det anses vara det bästa för att det ska vara attraktivt och prisvärt för kunderna.

  • 22.
    Alvarez, Victor
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Neuronik.
    Fahlstedt, Madelen
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Neuronik.
    Halldin, Peter
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Neuronik.
    Kleiven, Svein
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Neuronik.
    Importance of neck muscle tonus in head kinematics during pedestrian accidents2013Inngår i: 2013 IRCOBI Conference Proceedings - International Research Council on the Biomechanics of Injury, 2013, s. 747-761Konferansepaper (Fagfellevurdert)
    Abstract [en]

    Unprotected pedestrians are an exposed group in the rural traffic and the most vulnerable human body region is the head which is the source of many fatal injuries. This study was performed to gain a better understanding of the influence that the neck muscle tonus has on head kinematics during pedestrian accidents. This was done using a detailed whole body FE model and a detailed FE vehicle model. To determine the influence of the muscle tonus a series of simulations were performed where the vehicle speed, pedestrian posture and muscle tonus were varied. Since the human reaction time for muscle activation is in the order of the collision time, the pedestrian was assumed to be prepared for the oncoming vehicle in order to augment the possible influence of muscle tonus. From the simulations performed, kinematic data such as head rotations, trajectory and velocities were extracted for the whole collision event, as well as velocity and accelerations at head impact. These results show that muscle tonus can influence the head rotation during a vehicle collision and therefore alter the head impact orientation. The level of influence on head rotation was in general lower than when altering the struck leg forward and backward, but in the same order of magnitude for some cases. The influence on head accelerations was higher due to muscle tonus than posture in all cases.

  • 23.
    Alvarez, Victor S
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Neuronik.
    Kleiven, Svein
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Neuronik.
    Importance of Windscreen Modelling Approach for Head Injury Prediction2016Inngår i: 2016 IRCOBI Conference Proceedings - International Research Council on the Biomechanics of Injury, 2016Konferansepaper (Fagfellevurdert)
    Abstract [en]

    The objective of this study is to evaluate the capability of two modelling approaches in capturing  both accelerations and deformations from head impacts, and to evaluate the effect of modelling approach on  brain injury prediction. The first approach is a so‐called smeared technique, in which the properties of the two  glass  sheets and  the intermediate  polyvinyl  butyral  (PVB) are  combined and  divided into  two  coinciding  shell layers, of which one can fracture. The second approach consists of three shell layers, representing the glass and  PVB,  separated by  the  distance of  their  thickness, using a non‐local  failure criterion  to initiate  fracture in  the  glass.  The  two  modelling  approaches  are  compared  to  impact  experiments  of  flat  circular  windscreens,  measuring  deformations  and  accelerations  as  well  as  accelerations  from  impacts  against  full  vehicle  windscreens.  They  are  also  used  to  study  head‐to‐windscreen  impacts  using  a  detailed  Finite  Element  (FE)  model,  varying  velocity,  impact  direction  and  impact  point.  Only  the  non‐local  failure  model  is  able  to  adequately  capture  both  the accelerations and  deformations  of an  impactor. The FE  head model  simulations  also reveal that the choice of modelling approach has a large effect on the both localisation of the strain in the  brain and the characteristics of the strain‐time curve, with a difference in peak strain between 8% and 40%.  

  • 24.
    Amri, Abdurrahman
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    Hashosh, Wameedh
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    Visualisering av storadatamängder i en webbläsare2016Independent thesis Basic level (professional degree), 10 poäng / 15 hpOppgave
    Abstract [sv]

    Scania AB äger komplicerade testsystem som genererar stora och invecklade mängder av data. Ett av dessa testsystem är Hardware-In-the-Loop riggar (HIL) som testar elektriska system och genererar elektriska signaler samt resultat av de utförande testerna. Datat från dessa elektriska signaler skall sedan sparas i JSON-filer. För att dra nytta av Datat måste de sparas i en lämplig databas som kan be-handla denna data på ett bra sätt.Data från elektriska signaler beskriver olika fordonsegenskaper över tiden, vilket kan betraktas som en multivariat tidsserie.I det nuvarande systemet lagras och visualiseras data på ett ineffektivt sätt. Syftet med den första delen av studien är att undersöka 4 relevanta databaser som kan hantera JSON-filer. Den andra delen av detta arbete handlar om metoder för visua-lisering av signaler, det vill säga hur signaler kan representeras i form av grafer.Undersökningsresultat visade att två databaser är mer kvalificerade att ersätta den nuvarande databasen. CouchDB och PostgreSQL testades för att mäta deras pre-standa när det gäller lagring och hämtning av data.Testresultatet visade att CouchDB har högre prestanda för datahämtning än Post-greSQL. Därefter utvecklades en prototyp vars uppdrag var att visualisera signaler i webbläsare.

  • 25.
    Andersson, Andreas
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    Spirometri med en smarttelefon: Utveckling av en app för att mäta rotationshastigheten till en spirometerprototyp för smarttelefoner2017Independent thesis Basic level (university diploma), 10 poäng / 15 hpOppgave
    Abstract [sv]

    Målet med detta examensarbete har varit att utveckla en app med en algoritm för att mäta rotationshastigheten hos en prototyp för en spirometerlösning till en låg kostnad för smart- telefoner. En förstudie har gjorts av smarttelefoners användbarhet för att mäta hälsotillstånd och vilka alternativa lösningar och algoritmer som finns för att mäta rörelsedetektion. I detta arbete har en app med en algoritm utvecklats för att detektera rörelser och mäta rotations- hastigheten hos spirometerprototypens turbin filmad med en smarttelefonkamera. För att metoden ska fungera är det viktigt att rotationshastigheten understiger hälften av kamerans fps (bilder per sekund). Rotationshastigheten hos turbinen måste därför begränsas och det behövs en kamera som klarar minst 120 fps för att fånga rörelserna i prototypens turbin.Arbetet har resulterat i en fungerande algoritm för att bestämma turbinens rotationshastighet. Den utvecklade algoritmen detekterar topparna i en PPG (photoplethysmogram). För att minska beräkningstiden och för att öka noggrannheten analyserar algoritmen färgintensiteten i ett begränsat område, ett s.k. ROI (Region of Interest) i varje bild. Det finns stora möjligheter att använda denna algoritm för att fortsätta utvecklingen av detta alternativa sätt att utföra spirometritester.

  • 26.
    Andersson, Ida
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik.
    Hedvall, Anders
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik.
    Relationships Between Skin Properties and Body Water Level2013Independent thesis Advanced level (degree of Master (Two Years)), 20 poäng / 30 hpOppgave
    Abstract [en]

    A need for a quantitative method to determine body water level has been identified by a team of Clinical Innovation Fellows at the Centre for Technology in Medicine and Health (CTMH). A reliable way to determine body water level would bring great benefits to the healthcare sector, where no optimal method is available at the time of writing. A possible solution is a sensor that would measure alterations in skin properties due to changes in total body water. CTMH has had an idea of such a sensor, which is evaluated in this work. At an early stage of this evaluation process, it became clear that the research regarding correlations between skin properties and body hydration level was not sufficient to warrant the initiation of a sensor development process. Therefore, the main objective of this thesis became to investigate such correlations.

    An extensive literature review is presented, from which an experiment was developed. The experiment was performed on four human test subjects and involved measurements of skin thickness and elasticity parameters, before and after a weight loss of 3.2-3.7 % due to dehydration. The results showed clear decreases in skin thickness and indications of alterations in skin distensibility as well as in the skin’s immediate elastic response to applied negative pressure. It could also be seen that skin at different body sites does not respond in the same way - calves showed more distinct results than thighs and volar forearm.

    The material provided in this thesis encourages further studies of the correlation between the mentioned properties and total body water. If a predictable correlation can be found, a sensor development process could start. A reliable way to determine body water level would bring great benefits to the healthcare sector, where no optimal method is available at the time of writing.

  • 27.
    Andersson, Katarina
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Neuronik.
    Optimization of the Implantation Angle for a Talar Resurfacing Implant: A Finite Element Study2014Independent thesis Advanced level (degree of Master (Two Years)), 20 poäng / 30 hpOppgave
    Abstract [en]

    Osteochondral lesions of the talus (OLTs) are the third most common type of osteochondral lesion and can cause pain and instability of the ankle joint. Episurf Medical AB is a medical technology company that develops individualized implants for patients who are suffering from focal cartilage lesions. Episurf have recently started a project that aims to implement their implantation technique in the treatment of OLTs.

    This master thesis was a part of Episurf’s talus project and the main goal of the thesis was to find the optimal implantation angle of the Episurf implant when treating OLTs. The optimal implantation angle was defined as the angle that minimized the maximum equivalent (von Mises) strain acting on the implant shaft during the stance phase of a normal gait cycle. It is desirable to minimize the strain acting on the implant shaft, since a reduction of the strain can improve the longevity of the implant.

    To find the optimal implantation angle a finite element model of an ankle joint treated with the Episurf implant was developed. In the model an implant with a diameter of 12 millimeters was placed in the middle part of the medial side of the talar dome. An optimization algorithm was designed to find the implantation angle, which minimized the maximum equivalent strain acting on the implant shaft. The optimal implantation angle was found to be a sagittal angle of 12.5 degrees and a coronal angle of 0 degrees. Both the magnitude and the direction of the force applied to the ankle joint in the simulated stance phase seemed to influence the maximum equivalent strain acting on the implant shaft.

    A number of simplifications have been done in the simulation of this project, which might affect the accuracy of the results. Therefore it is recommended that further, more detailed, simulations based on this project are performed in order to improve the result accuracy.

  • 28.
    Andersson, Marcus
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    Implementation av en metod för prestandamätning av sensorkommunikation med Bluetooth low energy2016Independent thesis Basic level (university diploma), 10 poäng / 15 hpOppgave
    Abstract [sv]

    Internet of Things utvecklas och växer konstant. Det blir allt vanligare att applikationer och enheter kopplas samman via nätverk. En av teknikerna som används för att trådlöst sammankoppla enheter är Bluetooth Low Energy. Preferenser för kvaliteten i en kommunikation kan variera. Det är därför viktigt att utföra prestandamätningar för att veta vilka fördelar och nackdelar en nätverksteknik har. 

    Detta examensarbete handlar om prestandamätningar vid datasändningar mellan mobila enheter och trådlösa sensorer, och övervakning av parametrar som fås under mätningarna. En metod med monitoreringspaket inspirerad från tidigare forskning, utformades och implementerades i ett system för Bluetooth Low Energy, vilken därefter har utvärderats. 

    Resultatet blev att två system skapades som visade dataförluster, fördröjningsvariation och genomströmning, löpande på en mobil enhet. Det ena systemet använde metoden med monitoreringspaket. Det andra systemet använde en egengjord metod som gjorde mätningar med hög precision, men som ställde högre krav på funktioner och prestanda på sensornoden, och på den mobila enheten. Experiment med hjälp av systemen utfördes och resulterande värden analyserades.

  • 29. Andersson, Thord
    et al.
    Romu, Thobias
    Karlsson, Anette
    Norén, Bengt
    Forsgren, Mikael F
    Smedby, Örjan
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinsk bildbehandling och visualisering. KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Medicinteknik och hälsosystem, Medicinsk avbildning. Linköping University.
    Kechagias, Stergios
    Almer, Sven
    Lundberg, Peter
    Borga, Magnus
    Leinhard, Olof Dahlqvist
    Consistent intensity inhomogeneity correction in water-fat MRI2015Inngår i: Journal of Magnetic Resonance Imaging, ISSN 1053-1807, E-ISSN 1522-2586, Vol. 42, nr 2Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    PURPOSE: To quantitatively and qualitatively evaluate the water-signal performance of the consistent intensity inhomogeneity correction (CIIC) method to correct for intensity inhomogeneities

    METHODS: Water-fat volumes were acquired using 1.5 Tesla (T) and 3.0T symmetrically sampled 2-point Dixon three-dimensional MRI. Two datasets: (i) 10 muscle tissue regions of interest (ROIs) from 10 subjects acquired with both 1.5T and 3.0T whole-body MRI. (ii) Seven liver tissue ROIs from 36 patients imaged using 1.5T MRI at six time points after Gd-EOB-DTPA injection. The performance of CIIC was evaluated quantitatively by analyzing its impact on the dispersion and bias of the water image ROI intensities, and qualitatively using side-by-side image comparisons.

    RESULTS: CIIC significantly ( P1.5T≤2.3×10-4,P3.0T≤1.0×10-6) decreased the nonphysiological intensity variance while preserving the average intensity levels. The side-by-side comparisons showed improved intensity consistency ( Pint⁡≤10-6) while not introducing artifacts ( Part=0.024) nor changed appearances ( Papp≤10-6).

    CONCLUSION: CIIC improves the spatiotemporal intensity consistency in regions of a homogenous tissue type.

  • 30.
    Anthikat-Albert, Benedict D.
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik.
    Yiallourou, Theresia I.
    Haba-Rubio, Jose
    Heinzer, Raphael
    Fonari, Eleonora
    Chevrey, Nicolas
    Santini, Francesco
    Stergiopulos, Nikolaos
    Martin, Bryn A.
    Continuous positive airway pressure impacts cerebral blood flow and cerebrospinal fluid motion: A phase contrast mri study2012Inngår i: Proceedings Of The ASME 2012 Summer Bioengineering Conference, Parts A and B, ASME Press, 2012, s. 569-570Konferansepaper (Fagfellevurdert)
    Abstract [en]

    The physiological impacts of continuous positive airway pressure (CPAP) are not yet fully understood. In this study we developed an MRI protocol to assess the impact of CPAP on cerebral hemodynamics and cerebrospinal fluid (CSF) hydrodynamics in the upper cervical spine. MRI measurements were obtained on 14 healthy male subjects. The preliminary results indicated that the CSF pulsation decreased and venous outflow was altered with CPAP usage in comparison to the baseline values. Cerebral arterial flow was not impacted by CPAP usage. These findings support the hypothesis that the CSF system can act to dampen cerebral blood flow (CBF) pulsations.

  • 31.
    Araya, Cristian
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    Singh, Manjinder
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    Web API protocol and security analysis2017Independent thesis Basic level (university diploma), 10 poäng / 15 hpOppgave
    Abstract [en]

    There is problem that every company has its own customer portal. This problem can be solved by creating a platform that gathers all customers’ portals in one place. For such platform, it is required a web API protocol that is fast, secure and has capacity for many users. Consequently, a survey of various web API protocols has been made by testing their performance and security.

    The task was to find out which web API protocol offered high security as well as high performance in terms of response time both at low and high load. This included an investigation of previous work to find out if certain protocols could be ruled out. During the work, the platform’s backend was also developed, which needed to implement chosen web API protocols that would later be tested. The performed tests measured the APIs’ connection time and their response time with and without load. The results were analyzed and showed that the protocols had both pros and cons. Finally, a protocol was chosen that was suitable for the platform because it offered high security and fast connection. In addition, the server was not affected negatively by the number of connections. Reactive REST was the web API protocol chosen for this platform.

  • 32.
    Arrospide Echegaray, Daniel
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    Utvärdering av Självstyrandes-utvecklarramverket2016Independent thesis Basic level (professional degree), 10 poäng / 15 hpOppgave
    Abstract [sv]

    Inom mjukvaruteknik finns en mångfald processmetoder där var och en har ett specifikt syfte. En processmetod kan enklare beskrivas som en upprepningsbar uppsättning delsteg i syfte att utföra en uppgift och uppnå ett specifikt resultat. Majoriteten av processmetoder som har hittats i denna studie inriktar sig på den mjukvaruprodukt som är att utveckla. Det verkar finnas en brist på processmetoder som kan användas av mjukvaruutvecklare för att utveckla sin personliga utvecklingsprocess. Med personlig utvecklingsprocess menas, hur den enskilda utvecklaren väljer att strukturera det egna arbetet i syfte att uppnå ett visst re- sultat.

    Självstyrandes-utvecklarramverket (även kallad SGD-ramverket) är i skrivande stund ett nyligen utvecklat processramverk med syfte att bistå den individuella utvecklaren att ut- veckla sin personliga utvecklingsprocess. Kort beskrivet är ramverket tänkt att innehålla alla aktiviteter som kan komma att uppstå i ett utvecklingsprojekt. Problemet är att detta ramverk inte har utvärderats ännu och därför vet man inte om ramverket är relevant för att uppfylla sitt syfte. För att rama in och vägleda studien formulerades ett antal problemfråge- ställningar (1) Är ramverket fullständigt för ett mindre företag med avseende på aktivite- ter?, (2) Hur hög är kostnaden för SGD-ramverket i form av tid?

    Målet med studien är att bidra till framtida studier för ramverket genom att utföra en akt- ionsstudie där SGD-ramverket utvärderas utefter ett par specifika utvärderingskriterier.

    En induktiv kvalitativ forskningsmetod användes för att genomföra denna studie. Med in- duktiv metod menas att slutsatser dras utifrån empiriskt insamlad data och utifrån dessa ut- formas generella teorier. Mer specifikt användes metoden aktionsstudie. Data samlades in genom loggning och tidsloggning under aktionsstudiens gång. För att utvärdera ramverket användes utvärderingskriterierna (1) Fullständighet, (2) Semantisk korrekthet (3) Kostnad. En narrativ analys fördes över insamlad data för dessa kriterier med hänsyn till problemfrå- geställningarna.

    Resultat från utvärdering visade att ramverket inte ansågs fullständigt med hänsyn till dess aktiviteter. Dock näst intill fullständigt då enbart ett fåtal aktiviteter behövdes tilläggas i den utförda aktionsstudien. Totalt 3 extra aktiviteter lades till utöver de 40 som redan finns. Ca tio procent av den totala arbetstiden i aktionsstudien var i tillagda aktiviteter utanför Självstyrandes-Utvecklarramverkets ordinarie aktiviteter. Ramverkets aktiviteter ansågs även vara för granulärt formulerade i sammanhanget av ett mindre företag. Ramverket an- sågs vara högst relevant för att förbättra den individuella utvecklarens egna process. Kost- nad för införsel av Självstyrandes-Utvecklarramverket i denna studie speglar tiden det tog tills tidsanvändningen av Ramverket ansågs stabilt. Denna införelsekostnad uppskattades i form av tid och bestod av ca 3.54% av en åttatimmars arbetsdag, detta uppskattade ske un- der en införselsperiod på 24 dagar. Total tillämpningskostnad för användning av ramverket i den utförda aktionsstudien är i snitt 4,143 SEK/timme alternativt 662,88 SEK/månad. Schablonkostnaden som har använts ligger på 172,625 SEK/timme. 

  • 33.
    Aslamy, Benjamin
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    Utveckling av ett multisensorsystem för falldetekteringsanordningar2016Independent thesis Basic level (professional degree), 10 poäng / 15 hpOppgave
    Abstract [sv]

    Fallolyckor bland äldre är ett stort folkhälsoproblem. Således har det utvecklats en rad olika system för fjärrövervakning av äldre för att möjliggöra en tidig detekte- ring av fallolyckor. Majoriteten av de forskningar som hittills har gjorts inom fallo- lyckor har fokuserat på att utveckla nya mer framgångsrika algoritmer just för att identifiera fall från icke-fall. Trots det visar statistiken att dödsfall och skador orsa- kade av fallolyckor ökar för varje år i samband med den ökande andel äldre perso- ner i befolkningen.

    Detta examensarbete handlar om att förbättra nuvarande falldetekteringsanord- ningar genom att täcka de brister och tillgodose de behov som finns i nuvarande tekniker. De förbättringar som har kartlagts är att kunna ge en säkrare bedömning av patientens hälsa och kunna påkalla snabbare hjälpinsats när en fallolycka har inträffat. En annan förbättring är rörelsefriheten för äldre. De ska kunna befinna sig utomhus och ha möjlighet att utföra sina dagliga aktiviteter utan att vara be- gränsade av platspositionen.

    Sammanfattningsvis kan det konstateras att ett multisensorsystem i form av en prototyp har konstruerats för att täcka de brister som har kartlagts. Utöver att pro- totypen detekterar fall och kroppsrörelser med hjälp av en accelerometersensor innehåller den även en sensor för detektering av livstecken i from av EKG. Den in- nehåller dessutom cellulära och trådlösa nätverksanslutningar i form av GPRS och Wi-Fi för att möjliggöra rörelsefriheten hos äldre. Vidare innehåller prototypen en sensor för GPS som ger information om platsposition. 

  • 34.
    Atefi, Seyed Reza
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Electrical Bioimpedance Cerebral Monitoring: From Hypothesis and Simulation to First Experimental Evidence in Stroke Patients2015Doktoravhandling, med artikler (Annet vitenskapelig)
    Abstract [en]

    Stroke is amongthe leading causes of death worldwide and requires immediate care to prevent death or permanent disability. Unfortunately, the current stateof stroke diagnosis is limited to fixed neuroimaging facilities that do not allow rapid stroke diagnosis. Hence, a portable stroke-diagnosis device could assist in the pre-hospital triage of patients. Moreover, such a portable device could also be useful for bedside stroke monitoring of patients in the Neuro Intensive Care Unit (Neuro-ICU) to avoid unnecessary neuroimaging. Recent animal studies and numerical simulations have supported the idea of implementing Electrical Bioimpedance (EBI) in a portable device, allowing non-invasive assessment as a useful tool for the pre-hospital triage of stroke and Traumatic Brain Injury (TBI) patients. Unfortunately, these studies have not reported any results from human subjects in the acute phase of the stroke. The numerical simulations are also based on simple models that sometimes lack necessary details.

    Finite Element Method (FEM) simulations on a realistic numerical head model as well as experimental Bioimpedance Spectroscopy (BIS) measurements from human subjectsin the acute, subacute and chronic phasesof stroke were used to answer the following research questions: (i) Does stroke modify the electrical properties of brain tissue in a way that is detectable via EBI? (ii) Would it be possible to detect stroke via EBI as early as in the acute and sub-acute phase?(iii) Is EBI sensitive enough to monitor changes caused by stroke pathogenesis?

    Using FEM to simulate electrical current injection on the head and study the resulting distribution of electrical potential on the scalp, it was shown that Intra-Cranial Hemorrhage (ICH) affects the quasi-symmetric scalp potential distribution,creating larger left-right potential asymmetry when compared to the healthy head model. Proof-of-concept FEM simulations were also tested in a small cohort of 6ICH patients and 10 healthy controls, showing that the left-right potential difference in the patients is significantly (p<0.05) larger than in the controls. Using bioimpedance measurements in the acute,  subacute and chronic phasesof stroke and examining simple features, it was also shown that the head EBI measurements of patients suffering stroke are different from controls, enabling the discrimination of healthy controls and stroke patients at any stage of the stroke. The absolute change in test-retest resistance measurements of the control group (~5.33%) was also found to be significantly (p<0.05) smaller than the EBI measurements of patients obtained 24 hours and 72 hours after stroke onset (20.44%). These results suggested that scalp EBI is sensitive to stroke pathogenesis changesand thususeful for bedside monitoring in the Neuro-ICU. These results suggested that EBI is a potentially useful tool for stroke diagnosis and monitoring.

    Finally, the initial observations based on a small number of patients, addressing the proposed future work of this thesis, suggested that the average head resistance amplitude of hemorrhagic stroke patients is smaller than in healthy controls, while ischemic stroke patients show a larger resistance amplitude than the controls. Scalp potential asymmetry analysis of healthy, hemorrhagic and ischemic stroke subjects also suggests that these three groups can be separated. However, these results are based on a small number of patients and need to be validated using a larger cohort. Initial observations also showed that the resistance of the EBI measurements of controls is robust between test and retest measurements, showing no significant difference (less than 2% and p>0.05). Subject position during EBI recording (supine or sitting) did not seem to affect the resistance of the EBI measurements (p>0.05). However, age, sex and head size showed significant effects on the resistance measurements. These initial observations are encouraging for further research on EBI for cerebral monitoring and stroke diagnosis. However, at this stage, considering the uncertainties in stroke type differentiation, EBI cannot replace CT but has the potential to be used as a consultation tool.

  • 35.
    Atefi, Seyed Reza
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Seoane, Fernando
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Kamalian, Shervin
    Rosenthal, Eric
    Lev, Michael
    Bonmassar, Giorgio
    Intracranial haemorrhage alters scalp potential distributions in bioimpedance cerebral monitoring applications: preliminary results from FEM simulation on a realistic head model and human subjects2016Inngår i: Medical Physics, ISSN 2473-4209, Vol. 43, nr 2, s. 675-686Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Purpose: Current diagnostic neuroimaging for detection of intracranial hemorrhage (ICH) is limited to fixed scanners requiring patient transport and extensive infrastructure support. ICH diagnosis would therefore benefit from a portable diagnostic technology, such as electrical bioimpedance (EBI). Through simulations and patient observation, the authors assessed the influence of unilateral ICH hematomas on quasisymmetric scalp potential distributions in order to establish the feasibility of EBI technology as a potential tool for early diagnosis. Methods: Finite element method (FEM) simulations and experimental leftright hemispheric scalp potential differences of healthy and damaged brains were compared with respect to the asymmetry caused by ICH lesions on quasisymmetric scalp potential distributions. In numerical simulations, this asymmetry was measured at 25 kHz and visualized on the scalp as the normalized potential difference between the healthy and ICH damaged models. Proof-of-concept simulations were extended in a pilot study of experimental scalp potential measurements recorded between 0 and 50 kHz with the authors custom-made bioimpedance spectrometer. Mean leftright scalp potential differences recorded from the frontal, central, and parietal brain regions of ten healthy control and six patients suffering from acute/subacute ICH were compared. The observed differences were measured at the 5% level of significance using the two-sample Welch ttest. Results: The 3D-anatomically accurate FEM simulations showed that the normalized scalp potential difference between the damaged and healthy brain models is zero everywhere on the head surface, except in the vicinity of the lesion, where it can vary up to 5%. The authors preliminary experimental results also confirmed that the leftright scalp potential difference in patients with ICH (e.g., 64 mV) is significantly larger than in healthy subjects (e.g., 20.8 mV; P < 0.05). Conclusions: Realistic, proof-of-concept simulations confirmed that ICH affects quasisymmetric scalp potential distributions. Pilot clinical observations with the authors custom-made bioimpedance spectrometer also showed higher leftright potential differences in the presence of ICH, similar to those of their simulations, that may help to distinguish healthy subjects from ICH patients. Although these pilot clinical observations are in agreement with the computer simulations, the small sample size of this study lacks statistical power to exclude the influence of other possible confounders such as age, ex, and electrode positioning. The agreement with previously published simulation-based and clinical results, however, suggests that EBI technology may be potentially useful for ICH detection. © 2016 American Association of Physicists in Medicine.

  • 36.
    Atefi, Seyed Reza
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Seoane, Fernando
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Lindecrantz, Kaj
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Study of the dynamics of transcephalic cerebral impedance data during cardio-vascular surgery2013Inngår i: XV International Conference on Electrical Bio-Impedance (ICEBI) & XIV Conference on Electrical Impedance Tomography (EIT), Institute of Physics (IOP), 2013, Vol. 434, nr 1, s. 012045-Konferansepaper (Fagfellevurdert)
    Abstract [en]

    Postoperative neurological deficits are one of the risks associated with cardio vascular surgery, necessitating development of new techniques for cerebral monitoring. In this study an experimental observation regarding the dynamics of transcephalic Electrical Bioimpedance (EBI) in patients undergoing cardiac surgery with and without extracorporeal circulation (ECC) was conducted to investigate the potential use of electrical Bioimpedance for cerebral monitoring in cardio vascular surgery. Tetrapolar transcephalic EBI measurements at single frequency of 50 kHz were recorded prior to and during cardio vascular surgery. The obtained results show that the transcephalic impedance decreases in both groups of patients as operation starts, however slight differences in these two groups were also observed with the cerebral impedance reduction in patients having no ECC being less common and not as pronounced as in the ECC group. Changes in the cerebral impedance were in agreement with changes of haematocrit and temperature. The origin of EBI changes is still unexplained however these results encourage us to continue investigating the application of electrical bioimpedance cerebral monitoring clinically.

  • 37.
    Atefi, Seyed Reza
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Seoane, Fernando
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Thorlin, Thorleif
    Lindecrantz, Kaj
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Stroke Damage Detection Using Classification Trees on Electrical Bioimpedance Cerebral Spectroscopy Measurements2013Inngår i: Sensors, ISSN 1424-8220, E-ISSN 1424-8220, Vol. 13, nr 8, s. 10074-10086Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    After cancer and cardio-vascular disease, stroke is the third greatest cause of death worldwide. Given the limitations of the current imaging technologies used for stroke diagnosis, the need for portable non-invasive and less expensive diagnostic tools is crucial. Previous studies have suggested that electrical bioimpedance (EBI) measurements from the head might contain useful clinical information related to changes produced in the cerebral tissue after the onset of stroke. In this study, we recorded 720 EBI Spectroscopy (EBIS) measurements from two different head regions of 18 hemispheres of nine subjects. Three of these subjects had suffered a unilateral haemorrhagic stroke. A number of features based on structural and intrinsic frequency-dependent properties of the cerebral tissue were extracted. These features were then fed into a classification tree. The results show that a full classification of damaged and undamaged cerebral tissue was achieved after three hierarchical classification steps. Lastly, the performance of the classification tree was assessed using Leave-One-Out Cross Validation (LOO-CV). Despite the fact that the results of this study are limited to a small database, and the observations obtained must be verified further with a larger cohort of patients, these findings confirm that EBI measurements contain useful information for assessing on the health of brain tissue after stroke and supports the hypothesis that classification features based on Cole parameters, spectral information and the geometry of EBIS measurements are useful to differentiate between healthy and stroke damaged brain tissue.

  • 38.
    Atefi, Seyed Reza
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Seoane, Fernando
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Tomner, Jens
    Kostulas, Konstantinos
    Lindecrantz, Kaj
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Bonmassar, Giorgio
    Stroke Pathogenesis Alters Dielectric Properties of Brain Tissue Supporting Electrical Bioimpedance Technology as a tool for Cerebral MonitoringManuskript (preprint) (Annet vitenskapelig)
  • 39.
    Axtelius, Mathias
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    Alsawadi, Rami
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    An improved selection algorithm for access points in wireless local area networks: An improved selection algorithm for wireless iopsys devices2016Independent thesis Basic level (professional degree), 10 poäng / 15 hpOppgave
    Abstract [en]

    Wireless devices search for access points when they want to connect to a network. A devicechooses an access point based on the received signal strength between the device and theaccess point. That method is good for staying connected in a local area network but it doesnot always offer the best performance, which can result in a slower connection. This is thestandard method of connection for wireless clients, which will be referred to as the standardprotocol. Larger networks commonly have a lot of access points in an area, which increasesthe coverage area and makes loss of signal a rare occurrence. Overlapping coverage zonesare also common, offering multiple choices for a client. The company Inteno wanted an alternativeconnection method for their gateways. The new method that was developed wouldforce the client to connect to an access point depending on the bitrate to the master, as wellas the received signal strength. These factors are affected by many different parameters.These parameters were noise, signal strength, link-rate, bandwidth usage and connectiontype. A new metric had to be introduced to make the decision process easier by unifying theavailable parameters. The new metric that was introduced is called score. A score system wascreated based on these metrics. The best suited access point would be the one with the highestscore. The developed protocol chose the gateway with the highest bitrate available, while thestandard protocol would invariably pick the closest gateway regardless. The developed protocolcould have been integrated to the standard protocol to gain the benefits of both. Thiscould not be accomplished since the information was not easily accessible on Inteno’s gatewaysand had to be neglected in this thesis.

  • 40. Ayllnon, David
    et al.
    Gil-Pita, Roberto
    Seoane, Fernando
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
    Detection and Classification of Measurement Errors in Bioimpedance Spectroscopy2016Inngår i: PLoS ONE, ISSN 1932-6203, E-ISSN 1932-6203, Vol. 11, nr 6, artikkel-id e0156522Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Bioimpedance spectroscopy (BIS) measurement errors may be caused by parasitic stray capacitance, impedance mismatch, cross-talking or their very likely combination. An accurate detection and identification is of extreme importance for further analysis because in some cases and for some applications, certain measurement artifacts can be corrected, minimized or even avoided. In this paper we present a robust method to detect the presence of measurement artifacts and identify what kind of measurement error is present in BIS measurements. The method is based on supervised machine learning and uses a novel set of generalist features for measurement characterization in different immittance planes. Experimental validation has been carried out using a database of complex spectra BIS measurements obtained from different BIS applications and containing six different types of errors, as well as error-free measurements. The method obtained a low classification error (0.33%) and has shown good generalization. Since both the features and the classification schema are relatively simple, the implementation of this pre-processing task in the current hardware of bioimpedance spectrometers is possible.

  • 41. Azar, J.C.
    et al.
    Hamid Muhammed, Hamed
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik.
    Automated Tracking of the Carotid Artery in Ultrasound Image Sequences Using a Self Organizing Neural Network2010Inngår i: Proceedings of 20th International Conference on Pattern Recognition (ICPR 2010), Istanbul, Turkey, Istanbul, Turkey, 2010, s. 2548-2551Konferansepaper (Fagfellevurdert)
    Abstract [en]

    An automated method for the segmentation and tracking of moving vessel walls in 2D ultrasound image sequences is introduced. The method was tested on simulated and real ultrasound image sequences of the carotid artery. Tracking was achieved via a self organizing neural network known as Growing Neural Gas. This topology-preserving algorithm assigns a net of nodes connected by edges that distributes itself within the vessel walls and adapts to changes in topology with time. The movement of the nodes was analyzed to uncover the dynamics of the vessel wall. By this way, radial and longitudinal strain and strain rates have been estimated. Finally, wave intensity signals were computed from these measurements. The method proposed improves upon wave intensity wall analysis, WIWA, and opens up a possibility for easy and efficient analysis and diagnosis of vascular disease through noninvasive ultrasonic examination.

  • 42.
    Baitar, Rami
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    Riskanalys av elsystem med funktions-FMEA2014Independent thesis Advanced level (degree of Master (Two Years)), 20 poäng / 30 hpOppgave
    Abstract [sv]

    Riskanalysverktyget failure mode and effects analysis (FMEA) som analyserar kompo-nenter och signaler är beroende av att designen av fordonets elsystem finns tillgängligt och utförs därför sent i utvecklingsprocessen av elsystem. Detta medför att vissa fel inte analyseras i tid och kanske måste designas bort i efterhand vilket kan leda till ökad sy-stemkomplexitet samt längre och dyrare utvecklingsprocesser.Målet med examensarbetet är att genom en litteraturstudie ta reda på om det finns me-toder eller arbetssätt som gör att Scania tidigt i utvecklingsprocessen av elsystem kan genomföra funktionsanalyser i sitt riskanalysarbete med FMEA samt analysera dessa.Resultatet av detta examensarbete visar att det är möjligt att påbörja FMEA-arbetet tidigt i utvecklingsprocessen av elsystem om ingenjörerna utgår från ett funktionsperspektiv i riskanalysarbetet där de listar och rangordnar de funktioner som tillsammans realiserar en eller flera funktionaliteter samt deras felmoder, feleffekter, feldetektering, allvarlighet, sannolikhet och frekvens. Med hjälp av en FFMEA kan ingenjörerna tidigt i utveck-lingsprocessen av elsystem snabbt och effektivt hantera de identifierade säkerhetskritiska funktionerna.En befintlig funktionalitet på Scania har brutits ned i funktioner och en FFMEA har genomförts på dessa som en demonstration på hur en FFMEA kan genomföras och se ut.

  • 43. Bak, Zoltan
    et al.
    Sjöberg, Folke
    Hälsouniversitetet, Linköping University.
    Eriksson, Olle
    Steinvall, Ingrid
    Janerot-Sjoberg, Birgitta
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik.
    Hemodynamic changes during resuscitation after burns using the Parkland formula2009Inngår i: Journal of Trauma, ISSN 0022-5282, E-ISSN 1529-8809, Vol. 66, nr 2, s. 329-336Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    BACKGROUND: The Parkland formula (2-4 mL/kg/burned area of total body surface area %) with urine output and mean arterial pressure (MAP) as endpoints for the fluid resuscitation in burns is recommended all over the world. There has recently been a discussion on whether central circulatory endpoints should be used instead, and also whether volumes of fluid should be larger. Despite this, there are few central hemodynamic data available in the literature about the results when the formula is used correctly.

    METHODS: Ten burned patients, admitted to our unit early, and with a burned area of >20% of total body surface area were investigated at 12, 24, and 36 hours after injury. Using transesophageal echocardiography, pulmonary artery catheterization, and transpulmonary thermodilution to monitor them, we evaluated the cardiovascular coupling when urinary output and MAP were used as endpoints.

    RESULTS: Oxygen transport variables, heart rate, MAP, and left ventricular fractional area, did not change significantly during fluid resuscitation. Left ventricular end-systolic and end-diastolic area and global end-diastolic volume index increased from subnormal values at 12 hours to normal ranges at 24 hours after the burn. Extravascular lung water: intrathoracal blood volume ratio was increased 12 hours after the burn.

    CONCLUSIONS: Preload variables, global systolic function, and oxygen transport recorded simultaneously by three separate methods showed no need to increase the total fluid volume within 36 hours of a major burn. Early (12 hours) signs of central circulatory hypovolemia, however, support more rapid infusion of fluid at the beginning of treatment.

  • 44.
    Bandali, Benjamin
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Data- och elektroteknik.
    Availability and perceived availability with interaction design: Cost-effective availability model for a multinational company2014Independent thesis Basic level (university diploma), 10 poäng / 15 hpOppgave
    Abstract [sv]

    Olika tekniker för att beräkna webbtjänsters upp-tid har länge vart en viktig huvuddel till att förbättra samverkan och systemintegration. Tillgänglighet är den mest vanliga metoden när man presenterar dessa uträkningar där målet är främst att locka kunder, men kanske ännu viktigare att med hjälp av resultatet se hur man som utvecklare eller användare kan förbättra webbtjänsten. Tillgänglighet varierar mycket beroende på vad det är för typ av tjänst, företag eller användning, och ett vanligt problem är definitionen av vad tillgänglighet egentligen är.

    Det här arbetet kommer att ge dess läsare en introduktion till området tillgänglighet, och förklara varför den varierar, vilket är grunden till teorin bakom interaktionsdesign. Tillgänglighet är ett mätvärde som kan beräknas på många olika sätt, och generar ett resultat som är komplext för användarna som tar del av det.

    Målet blir främst att ge läsaren en uppfattning och riktlinjer om hur man kan definiera den upplevda tillgängligheten baserat på ett systems tillgänglighet, men också presentera metoder till att definiera, beräkna och presentera variabeln i en användarvänlig procedur. Resultatet kommer i sin tur att bestå av en kostnadseffektiv modell för upplevd tillgänglighet och bli testad på ett multinationellt företag.

  • 45. Barrefelt, Asa
    et al.
    Zhao, Ying
    Larsson, Malin K.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinsk bildteknik.
    Egri, Gabriella
    Kuiper, Raoul V.
    Hamm, Jorg
    Saghafian, Maryam
    Caidahl, Kenneth
    Brismar, Torkel B.
    Aspelin, Peter
    Heuchel, Rainer
    Muhammed, Mamoun
    Dahne, Lars
    Hassan, Moustapha
    Fluorescence labeled microbubbles for multimodal imaging2015Inngår i: Biochemical and Biophysical Research Communications - BBRC, ISSN 0006-291X, E-ISSN 1090-2104, Vol. 464, nr 3, s. 737-742Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Air-filled polyvinyl alcohol microbubbles (PVA-MBs) were recently introduced as a contrast agent for ultrasound imaging. In the present study, we explore the possibility of extending their application in multimodal imaging by labeling them with a near infrared (NIR) fluorophore, VivoTag-680. PVA-MBs were injected intravenously into FVB/N female mice and their dynamic biodistribution over 24 h was determined by 3D-fluorescence imaging co-registered with 3D-mu CT imaging, to verify the anatomic location. To further confirm the biodistribution results from in vivo imaging, organs were removed and examined histologically using bright field and fluorescence microscopy. Fluorescence imaging detected PVA-MB accumulation in the lungs within the first 30 min post-injection. Redistribution to a low extent was observed in liver and kidneys at 4 h, and to a high extent mainly in the liver and spleen at 24 h. Histology confirmed PVA-MB localization in lung capillaries and macrophages. In the liver, they were associated with Kupffer cells; in the spleen, they were located mostly within the marginal-zone. Occasional MBs were observed in the kidney glomeruli and interstitium. The potential application of PVA-MBs as a contrast agent was also studied using ultrasound (US) imaging in subcutaneous and orthotopic pancreatic cancer mouse models, to visualize blood flow within the tumor mass. In conclusion, this study showed that PVA-MBs are useful as a contrast agent for multimodal imaging. (C) 2015 Elsevier Inc. All rights reserved.

  • 46. Bassan, Gioia
    et al.
    Larsson, David
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinsk bildteknik.
    Nordenfur, Tim
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinsk bildteknik.
    Bjällmark, Anna
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinsk bildteknik.
    Larsson, Matilda
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinsk bildteknik.
    Acquisition of multiple mode shear wave propagation in transversely isotropic medium using dualprobe setup2015Konferansepaper (Fagfellevurdert)
  • 47. Beillas, P.
    et al.
    Petit, P.
    Kleiven, Svein
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Neuronik.
    Kirscht, S.
    Chawla, A.
    Jolivet, E.
    Faure, F.
    Praxl, N.
    Bhaskar, A.
    Specifications of a software framework to position and personalise human body models2015Inngår i: 2015 IRCOBI Conference Proceedings - International Research Council on the Biomechanics of Injury, International Research Council on the Biomechanics of Injury , 2015, s. 594-595Konferansepaper (Fagfellevurdert)
  • 48.
    Bekkouche, Bo
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik.
    Functional Implications from Changes in Volume and Periaxonal Space of C-fibers2012Independent thesis Basic level (degree of Bachelor), 10 poäng / 15 hpOppgave
  • 49.
    Bennati, Paolo
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik.
    Dasu, A.
    Colarieti-Tosti, Massimiliano
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinsk bildteknik.
    Lönn, Gustaf
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik.
    Larsson, David
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinsk bildteknik.
    Fabbri, A.
    Galasso, M.
    Cinti, M. N.
    Pellegrini, R.
    Pani, R.
    Preliminary study of a new gamma imager for on-line proton range monitoring during proton radiotherapy2017Inngår i: Journal of Instrumentation, ISSN 1748-0221, E-ISSN 1748-0221, Vol. 12, nr 5, artikkel-id C05009Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    We designed and tested new concept imaging devices, based on a thin scintillating crystal, aimed at the online monitoring of the range of protons in tissue during proton radiotherapy. The proposed crystal can guarantee better spatial resolution and lower sensitivity with respect to a thicker one, at the cost of a coarser energy resolution. Two different samples of thin crystals were coupled to a position sensitive photo multiplier tube read out by 64 independent channels electronics. The detector was equipped with a knife-edge Lead collimator that defined a reasonable field of view of about 10 cm in the target. Geant4 Monte Carlo simulations were used to optimize the design of the experimental setup and assess the accuracy of the results. Experimental measurements were carried out at the Skandion Clinic, the recently opened proton beam facility in Uppsala, Sweden. PMMA and water phantoms studies were performed with a first prototype based on a round 6.0 mm thick Cry019 crystal and with a second detector based on a thinner 5 × 5 cm2, 2.0 mm thick LFS crystal. Phantoms were irradiated with mono-energetic proton beams whose energy was in the range between 110 and 160 MeV. According with the simulations and the experimental data, the detector based on LFS crystal seems able to identify the peak of prompt-gamma radiation and its results are in fair agreement with the expected shift of the proton range as a function of energy. The count rate remains one of the most critical limitations of our system, which was able to cope with only about 20% of the clinical dose rate. Nevertheless, we are confident that our study might provide the basis for developing a new full-functional system.

  • 50.
    Bergholm, Fredrik
    et al.
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik.
    Hamid Muhammed, Hamed
    KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik.
    Larsolle, A.
    Acquiring instantaneous multispectral imagery using a single image sensor with multiple filter mosaic2007Konferansepaper (Annet vitenskapelig)
1234567 1 - 50 of 625
RefereraExporteraLink til resultatlisten
Permanent link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf