Change search
Refine search result
1 - 2 of 2
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Rows per page
  • 5
  • 10
  • 20
  • 50
  • 100
  • 250
Sort
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
Select
The maximal number of hits you can export is 250. When you want to export more records please use the 'Create feeds' function.
  • 1.
    Chotteau, Veronique
    et al.
    KTH, School of Biotechnology (BIO), Bioprocess Technology.
    Tördahl, Karin
    KTH, School of Biotechnology (BIO), Bioprocess Technology.
    Perroud, Philip
    KTH, School of Biotechnology (BIO), Bioprocess Technology.
    Unthan, Simon
    KTH, School of Biotechnology (BIO), Bioprocess Technology.
    Schmidt, Johannes RM
    KTH, School of Biotechnology (BIO), Bioprocess Technology.
    Doverskog, Magnus
    IMED, AB, Solna, Sweden.
    Study of Alternating Tangential Flow filtration for perfusion and harvest in Chinese Hamster Ovary cells cultivation2010In: Proceedings of the Cell Culture Engineering Conference XII, April 25-30, 2010, Banff, Canada, 2010Conference paper (Other academic)
    Abstract [en]

    Perfusion is a mode of operation where a continuous replacement of the conditioned medium by fresh medium is operated. It has the advantage of allowing high cell densities. This mode of operations is also required for some instable proteins since the cell-free supernatant containing the product of interest is immediately stored at low temperature where the proteolysis is not active. The ATF filtration device, Alternating Tangential Flow, has been designed to perfuse mammalian cell cultivation process and is used (or studied) nowadays for applications like perfusion, medium renewal, harvest, etc. The cell broth circulation back and forward in the filter prevents the filter clogging and the design ensures a low shear not damageable for the cells.

    A perfusion process operated by ATF filtration and using CHO cells producing a monoclonal antibody was developed in a 2 L bioreactor. The medium did not contain animal derived components. Cell densities above 40 x 1E6 cells/mL were obtained with a perfusion rate of 2 reactor volume/day. The highest cell density observed was 48 x 1E6 cells/mL. These high cell densities were challenging for the aeration. Pure oxygen aeration by large bubbles from an open tube resulted in satisfying oxygenation until 25 to 30 x 1E6 cells/mL but became limiting at higher cell densities due to the low kLa of these bubbles and the small liquid height. At higher cell densities, a porous sparger with pure oxygen was used either alone or in combination with the open tube aeration. Automatic delivery of antifoam C and pluronic counteracted the effect of small bubble foam deleterious for the cells. From an operation point-of-view, the perfusion operated by the ATF device was satisfying, without filter fouling, easy to operate and to adjust in comparison with other separation devices by filtration or gravitation.

    Finally harvesting by ATF filtration was evaluated in comparison with ‘one-way’ tangential flow filtration, TFF, on an IgG producing CHO fed-batch process produced in 2 L bioreactor and in 20 L bioreactor. Different settings and filter sizes were compared and the effect of varying the flow rate was studied.

  • 2.
    Chotteau, Veronique
    et al.
    KTH, School of Biotechnology (BIO), Bioprocess Technology.
    Tördal, Karin
    KTH, School of Biotechnology (BIO), Bioprocess Technology.
    Perroud, Philip
    KTH, School of Biotechnology (BIO), Bioprocess Technology.
    Unthan, Simon
    KTH, School of Biotechnology (BIO), Bioprocess Technology.
    Schmidt, Johannes R.M.
    KTH, School of Biotechnology (BIO), Bioprocess Technology.
    Doverskog, Magnus
    IMED, AB, Solna, Sweden.
    Study of Alternating Tangential Flow filtration for perfusion and harvest in Chinese Hamster Ovary cells cultivation2010Other (Other academic)
    Abstract [en]

    Perfusion is a mode of operation where a continuous replacement of the conditioned medium by fresh medium is operated. It has the advantage of allowing high cell densities. This mode of operations is also required for some instable proteins since the cell-free supernatant containing the product of interest is immediately stored at low temperature where the proteolysis is not active. The ATF filtration device, Alternating Tangential Flow, has been designed to perfuse mammalian cell cultivation process and is used (or studied) nowadays for applications like perfusion, medium renewal, harvest, etc. The cell broth circulation back and forward in the filter prevents the filter clogging and the design ensures a low shear not damageable for the cells.

    A perfusion process operated by ATF filtration and using CHO cells producing a monoclonal antibody was developed in a 2 L bioreactor. The medium did not contain animal derived components. Cell densities above 40 x 106 cells/mL were obtained with a perfusion rate of 2 reactor volume/day. The highest cell density observed was 48 x 106 cells/mL. These high cell densities were challenging for the aeration. Pure oxygen aeration by large bubbles from an open tube resulted in satisfying oxygenation until 25 to 30 x 106 cells/mL but became limiting at higher cell densities due to the low kLa of these bubbles and the small liquid height. At higher cell densities, a porous sparger with pure oxygen was used either alone or in combination with the open tube aeration. Automatic delivery of antifoam C and pluronic counteracted the effect of small bubble foam deleterious for the cells. From an operation point-of-view, the perfusion operated by the ATF device was satisfying, without filter fouling, easy to operate and to adjust in comparison with other separation devices by filtration or acceleration.

     

    Finally harvesting by ATF filtration was evaluated in comparison with ‘one-way’ tangential flow filtration, TFF, on an IgG producing CHO fed-batch process produced in 2 L bioreactor. In both operation modes, ATF and TFF, filter fouling occurred after several minutes and the total process time was comparable but an important difference was that the viability drop obtained when using ATF was 15 % while it was 45 % using the TFF.

1 - 2 of 2
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf