Endre søk
Link to record
Permanent link

Direct link
Alternativa namn
Publikasjoner (10 av 49) Visa alla publikasjoner
Awaki, H., Gau, E., Kiss, M., Klepper, K., af Malmborg, F., Pearce, M. & Yoshimoto, M. (2025). XL-Calibur measurements of polarized hard X-ray emission from the Crab. Monthly notices of the Royal Astronomical Society, 540(1), L34-L40
Åpne denne publikasjonen i ny fane eller vindu >>XL-Calibur measurements of polarized hard X-ray emission from the Crab
Vise andre…
2025 (engelsk)Inngår i: Monthly notices of the Royal Astronomical Society, ISSN 0035-8711, E-ISSN 1365-2966, Vol. 540, nr 1, s. L34-L40Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

We report measurements of the linear polarization degree (PD) and angle (PA) for hard X-ray emission from the Crab pulsar and wind nebula. Measurements were made with the XL-Calibur (similar to 15-80 keV) balloon-borne Compton-scattering polarimeter in July 2024. The polarization parameters are determined using a Bayesian analysis of Stokes parameters obtained from X-ray scattering angles. Well-constrained (similar to 8.5 sigma) results are obtained for the polarization of the similar to 19-64 keV signal integrated over all pulsar phases: PD = (25.1 +/- 2.9) per cent and PA = (129.8 +/- 3.2)degrees. In the off-pulse (nebula-dominated) phase range, the PD is constrained at similar to 4.5 sigma and is compatible with the phase-integrated result. The PA of the nebular hard X-ray emission aligns with that measured by IXPE in the 2-8 keV band for the toroidal inner region of the pulsar wind nebula, where the hard X-rays predominantly originate. For the main pulsar peak, PD = (32.8(-28.5)(+18.2)) per cent and PA = (156.0 +/- 21.7)degrees, while for the second peak (inter-pulse), PD = (0.0(-0.0)(+33.6)) per cent and PA = (154.5 +/- 34.5)degrees. A low level of polarization in the pulsar peaks likely does not favour emission originating from the inner regions of the pulsar magnetosphere. Discriminating between Crab pulsar emission models will require deeper observations, e.g. with a satellite-borne hard X-ray polarimeter.

sted, utgiver, år, opplag, sider
Oxford University Press (OUP), 2025
Emneord
instrumentation: polarimeters, methods: statistical, techniques: polarimetric, X-rays: individual: Crab
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-375049 (URN)10.1093/mnrasl/slaf026 (DOI)001594574400007 ()2-s2.0-105003850218 (Scopus ID)
Merknad

QC 20260113

Tilgjengelig fra: 2026-01-13 Laget: 2026-01-13 Sist oppdatert: 2026-01-13bibliografisk kontrollert
Kiss, M. & Pearce, M. (2024). Bayesian Analysis of the Data from PoGO+. In: Bambi, C., Santangelo, A. (Ed.), Handbook of X-ray and Gamma-ray Astrophysics: (pp. 5683-5716). Springer Nature
Åpne denne publikasjonen i ny fane eller vindu >>Bayesian Analysis of the Data from PoGO+
2024 (engelsk)Inngår i: Handbook of X-ray and Gamma-ray Astrophysics / [ed] Bambi, C., Santangelo, A., Springer Nature , 2024, s. 5683-5716Kapittel i bok, del av antologi (Annet vitenskapelig)
Abstract [en]

PoGO+ is a Compton-scattering polarimeter, which measured the linear polarization of hard X-rays (~20-170 keV) emitted by the Crab nebula/pulsar and the black-hole binary Cygnus X-1. Measurements were conducted from a stabilized balloon-borne platform in the stratosphere in July 2016. Polarization properties were determined by measuring the distribution of azimuthal Compton-scattering angles in an array of collimated plastic scintillators, housed in a thick Bi4Ge3O12 anticoincidence shield. Observations are complicated by the significant flux of background particles present in the stratosphere due to the interaction of primary cosmic rays with the upper layers of the atmosphere. The resulting modest signal-to-background ratio of ~1/7, combined with the positive-definite nature of the measurements, motivates a data analysis using Bayesian statistics. The Bayesian method is not limited to PoGO+ data but is universal and can thus be used for any instruments and detection techniques in high-energy polarimetry. After an overview of the instrument measurement principles and design, the data-analysis procedure is described in detail. This chapter concludes with an overview of results from observations and a discussion on the future development of balloon-borne hard X-ray polarimetry, including missions that are currently being prepared for flight.

sted, utgiver, år, opplag, sider
Springer Nature, 2024
Emneord
Bayesian analysis, Compton polarimetry, Crab pulsar/nebula, Cygnus X-1, Data pipeline/reduction, Scientific ballooning/payloads, Stokes parameters, X-rays
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-355919 (URN)10.1007/978-981-19-6960-7_141 (DOI)2-s2.0-85207576853 (Scopus ID)
Merknad

Part of ISBN 9789811969607, 9789811969591

QC 20241107

Tilgjengelig fra: 2024-11-06 Laget: 2024-11-06 Sist oppdatert: 2024-11-07bibliografisk kontrollert
Aoyagi, M., Bose, R. G., Chun, S., Gau, E., Hu, K., Ishiwata, K., . . . Yoshimoto, M. (2024). Systematic effects on a Compton polarimeter at the focus of an X-ray mirror. Astroparticle physics, 158, Article ID 102944.
Åpne denne publikasjonen i ny fane eller vindu >>Systematic effects on a Compton polarimeter at the focus of an X-ray mirror
Vise andre…
2024 (engelsk)Inngår i: Astroparticle physics, ISSN 0927-6505, E-ISSN 1873-2852, Vol. 158, artikkel-id 102944Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

XL-Calibur is a balloon-borne Compton polarimeter for X-rays in the ∼15–80 keV range. Using an X-ray mirror with a 12 m focal length for collecting photons onto a beryllium scattering rod surrounded by CZT detectors, a minimum-detectable polarization as low as ∼3% is expected during a 24-hour on-target observation of a 1 Crab source at 45° elevation. Systematic effects alter the reconstructed polarization as the mirror focal spot moves across the beryllium scatterer, due to pointing offsets, mechanical misalignment or deformation of the carbon-fiber truss supporting the mirror and the polarimeter. Unaddressed, this can give rise to a spurious polarization signal for an unpolarized flux, or a change in reconstructed polarization fraction and angle for a polarized flux. Using bench-marked Monte-Carlo simulations and an accurate mirror point-spread function characterized at synchrotron beam-lines, systematic effects are quantified, and mitigation strategies discussed. By recalculating the scattering site for a shifted beam, systematic errors can be reduced from several tens of percent to the few-percent level for any shift within the scattering element. The treatment of these systematic effects will be important for any polarimetric instrument where a focused X-ray beam is impinging on a scattering element surrounded by counting detectors.

sted, utgiver, år, opplag, sider
Elsevier BV, 2024
Emneord
Balloon-borne telescope, Bench-marking, Compton polarimetry, Modulation response, Monte-Carlo simulations, Offset correction, X-ray optics
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-344000 (URN)10.1016/j.astropartphys.2024.102944 (DOI)001198087900001 ()2-s2.0-85185398384 (Scopus ID)
Merknad

QC 20240229

Tilgjengelig fra: 2024-02-28 Laget: 2024-02-28 Sist oppdatert: 2024-04-29bibliografisk kontrollert
Iyer, N., Kiss, M., Pearce, M., Stana, T.-A., Awaki, H., Bose, R. G., . . . Yoshimoto, M. (2023). The design and performance of the XL-Calibur anticoincidence shield. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1048, Article ID 167975.
Åpne denne publikasjonen i ny fane eller vindu >>The design and performance of the XL-Calibur anticoincidence shield
Vise andre…
2023 (engelsk)Inngår i: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, ISSN 0168-9002, E-ISSN 1872-9576, Vol. 1048, artikkel-id 167975Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The XL-Calibur balloon-borne hard X-ray polarimetry mission comprises a Compton-scattering polarimeter placed at the focal point of an X-ray mirror. The polarimeter is housed within a BGO anticoincidence shield, which is needed to mitigate the considerable background radiation present at the observation altitude of ∼40 km. This paper details the design, construction and testing of the anticoincidence shield, as well as the performance measured during the week-long maiden flight from Esrange Space Centre to the Canadian Northwest Territories in July 2022. The in-flight performance of the shield followed design expectations, with a veto threshold <100 keV and a measured background rate of ∼0.5 Hz (20–40 keV). This is compatible with the scientific goals of the mission, where %-level minimum detectable polarisation is sought for a Hz-level source rate.

sted, utgiver, år, opplag, sider
Elsevier BV, 2023
Emneord
Anticoincidence, BGO scintillator, Monte Carlo, Photomultiplier tube, Qualification testing, Scientific ballooning, X-ray polarimetry
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-330081 (URN)10.1016/j.nima.2022.167975 (DOI)000995686300001 ()2-s2.0-85146099547 (Scopus ID)
Merknad

QC 20230626

Tilgjengelig fra: 2023-06-26 Laget: 2023-06-26 Sist oppdatert: 2023-11-29bibliografisk kontrollert
Kamogawa, W., Iyer, N., Kiss, M., Pearce, M., Ryde, F., Stana, T.-A. & Yoshida, Y. (2022). Optical performance of the X-ray telescope for the XL-Calibur experiment. In: DenHerder, JWA Nikzad, S Nakazawa, K (Ed.), Space Telescopes And Instrumentation 2022: Ultraviolet To Gamma Ray. Paper presented at Conference on Space Telescopes and Instrumentation - Ultraviolet to Gamma Ray Part of SPIE Astronomical Telescopes and Instrumentation Conference, July 17-22, 2022, Montreal, CANADA. SPIE-Intl Soc Optical Eng, 12181, Article ID 1218171.
Åpne denne publikasjonen i ny fane eller vindu >>Optical performance of the X-ray telescope for the XL-Calibur experiment
Vise andre…
2022 (engelsk)Inngår i: Space Telescopes And Instrumentation 2022: Ultraviolet To Gamma Ray / [ed] DenHerder, JWA Nikzad, S Nakazawa, K, SPIE-Intl Soc Optical Eng , 2022, Vol. 12181, artikkel-id 1218171Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

XL-Calibur is a balloon-borne mission for hard X-ray polarimetry. The first launch is currently scheduled from Sweden in summer 2022. Japanese collaborators provide a hard X-ray telescope to the mission. The telescope's design is identical to the Hard X-ray Telescope (HXT, conically-approximated Wolter-I optics) on board ASTRO-H with the same focal length of 12 m and the aperture of 45 cm, which can focus X-rays up to 80 keV. The telescope is divided into three segments in the circumferential direction, and confocal 213 grazing-incidence mirrors are precisely placed in the primary and secondary sections of each segment. The surfaces of the mirrors are coated with Pt/C depth-graded multilayer to reflect hard X-rays efficiently by the Bragg reflection. To achieve the best focus, optical adjustment of all of the segments was performed at the SPring-8/BL20B2 synchrotron radiation facility during 2020. A final performance evaluation was conducted in June 2021 and the experiment yields the effective area of 175 cm(2) and 73 cm(2) at 30 keV and 50 keV, respectively, with its half-power diameter of the point spread function as 2.1 arcmin. The field of view, defined as the full width of the half-maximum of the vignetting curve, is 5.9 arcmin.

sted, utgiver, år, opplag, sider
SPIE-Intl Soc Optical Eng, 2022
Serie
Proceedings of SPIE, ISSN 0277-786X
Emneord
X-ray astronomy, XL-Calibur, polarimetry, X-ray telescope
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-321628 (URN)10.1117/12.2626537 (DOI)000865607100164 ()2-s2.0-85140466992 (Scopus ID)
Konferanse
Conference on Space Telescopes and Instrumentation - Ultraviolet to Gamma Ray Part of SPIE Astronomical Telescopes and Instrumentation Conference, July 17-22, 2022, Montreal, CANADA
Merknad

QC 20221121

Part of proceedings: ISBN 978-1-5106-5344-3; 978-1-5106-5343-6

Tilgjengelig fra: 2022-11-21 Laget: 2022-11-21 Sist oppdatert: 2022-11-21bibliografisk kontrollert
Abarr, Q., Iyer, N., Kislat, F., Kiss, M., Pearce, M., West, A. & et al., . (2022). Performance of the X-Calibur hard X-ray polarimetry mission during its 2018/19 long-duration balloon flight. Astroparticle physics, 143, 102749, Article ID 102749.
Åpne denne publikasjonen i ny fane eller vindu >>Performance of the X-Calibur hard X-ray polarimetry mission during its 2018/19 long-duration balloon flight
Vise andre…
2022 (engelsk)Inngår i: Astroparticle physics, ISSN 0927-6505, E-ISSN 1873-2852, Vol. 143, s. 102749-, artikkel-id 102749Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

X-Calibur is a balloon-borne telescope that measures the polarization of high-energy X-rays in the 15-50 keV energy range. The instrument makes use of the fact that X-rays scatter preferentially perpendicular to the polarization direction. A beryllium scattering element surrounded by pixellated CZT detectors is located at the focal point of the InFOC mu S hard X-ray mirror. The instrument was launched for a long-duration balloon (LDB) flight from McMurdo (Antarctica) on December 29, 2018, and obtained the first constraints of the hard X-ray polarization of an accretion-powered pulsar. Here, we describe the characterization and calibration of the instrument on the ground and its performance during the flight, as well as simulations of particle backgrounds and a comparison to measured rates. The pointing system and polarimeter achieved the excellent projected performance. The energy detection threshold for the anticoincidence system was found to be higher than expected and it exhibited unanticipated dead time. Both issues will be remedied for future flights. Overall, the mission performance was nominal, and results will inform the design of the follow-up mission XL-Calibur, which is scheduled to be launched in summer 2022.

sted, utgiver, år, opplag, sider
Elsevier BV, 2022
Emneord
X-ray, Polarization, Instrumentation
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-316452 (URN)10.1016/j.astropartphys.2022.102749 (DOI)000830204300001 ()2-s2.0-85133615723 (Scopus ID)
Merknad

QC 20220818

Tilgjengelig fra: 2022-08-18 Laget: 2022-08-18 Sist oppdatert: 2022-08-18bibliografisk kontrollert
Hattori, K., Iyer, N., Kiss, M., Pearce, M., Ryde, F., Stana, T.-A. & Yoshida, Y. (2021). Current status of the X-ray mirror for the XL-Calibur experiment. In: DenHerder, JWA Nikzad, S Nakazawa, K (Ed.), Space Telescopes and Instrumentation 2020: Ultraviolet To Gamma Ray. Paper presented at Conference on Space Telescopes and Instrumentation - Ultraviolet to Gamma Ray / SPIE Astronomical Telescopes + Instrumentation Conference, DEC 14-18, 2020, ELECTR NETWORK. SPIE-Intl Soc Optical Eng, Article ID 114445W.
Åpne denne publikasjonen i ny fane eller vindu >>Current status of the X-ray mirror for the XL-Calibur experiment
Vise andre…
2021 (engelsk)Inngår i: Space Telescopes and Instrumentation 2020: Ultraviolet To Gamma Ray / [ed] DenHerder, JWA Nikzad, S Nakazawa, K, SPIE-Intl Soc Optical Eng , 2021, artikkel-id 114445WKonferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

XL-Calibur is a balloon-borne hard X-ray polarimetry mission, the first flight of which is currently foreseen for 2022. XL-Calibur carries an X-ray telescope consists of 213 Wolter I grazing-incidence mirrors which are nested in a coaxial and cofocal configuration. The optics design is nearly identical to the Hard X-ray Telescope (HXT) on board the ASTRO-H satellite. The telescope was originally fabricated for the Formation Flying Astronomical Survey Telescope (FFAST) project. However, the telescope can be used for XL-Calibur, since the FFAST project was terminated before completion. The mirror surfaces are coated with Pt/C depth-graded multilayers to reflect hard X-rays above 10 keV by Bragg reflection. The effective area of the telescope is larger than 300 cm(2) at 20 keV. This paper reports the current status of the telescope for XL-Calibur.

sted, utgiver, år, opplag, sider
SPIE-Intl Soc Optical Eng, 2021
Serie
Proceedings of SPIE, ISSN 0277-786X ; 11444
Emneord
XL-Calibur, polarimetry, X-ray telescope
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-300364 (URN)10.1117/12.2560928 (DOI)000674737700090 ()2-s2.0-85099280098 (Scopus ID)
Konferanse
Conference on Space Telescopes and Instrumentation - Ultraviolet to Gamma Ray / SPIE Astronomical Telescopes + Instrumentation Conference, DEC 14-18, 2020, ELECTR NETWORK
Merknad

Part of proceedings: ISBN 978-1-5106-3676-7, QC 20230117

Tilgjengelig fra: 2021-08-31 Laget: 2021-08-31 Sist oppdatert: 2023-01-17bibliografisk kontrollert
Abarr, Q., Iyer, N., Kiss, M., Maeda, Y., Pearce, M., Ryde, F., . . . Yoshida, Y. (2021). "XL-Calibur", the Next-Generation Balloon-Borne Hard X-ray Polarimeter. In: DenHerder, JWA Nikzad, S Nakazawa, K (Ed.), Space Telescopes and Instrumentation 2020: Ultraviolet to Gamma Ray. Paper presented at Conference on Space Telescopes and Instrumentation - Ultraviolet to Gamma Ray / SPIE Astronomical Telescopes + Instrumentation Conference, DEC 14-18, 2020, ELECTR NETWORK. SPIE-Intl Soc Optical Eng, Article ID 114442X.
Åpne denne publikasjonen i ny fane eller vindu >>"XL-Calibur", the Next-Generation Balloon-Borne Hard X-ray Polarimeter
Vise andre…
2021 (engelsk)Inngår i: Space Telescopes and Instrumentation 2020: Ultraviolet to Gamma Ray / [ed] DenHerder, JWA Nikzad, S Nakazawa, K, SPIE-Intl Soc Optical Eng , 2021, artikkel-id 114442XKonferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

This paper introduces a second-generation balloon-borne hard X-ray polarimetry mission, XL-Calibur.(1) The XL-Calibur will follow up on the X-Calibur mission which was flown from Dec. 29, 2018 for a 2.5 days balloon flight from McMurdo (the Antarctic). X-ray polarimetry promises to give qualitatively new information about high-energy astrophysical sources, such as pulsars and binary black hole systems. The XL-Calibur contains a grazing incidence X-ray telescope with a focal plane detector unit that is sensitive to linear polarization. The telescope is very similar in design to the ASTRO-H HXT telescopes that has the world's largest effective area above 10 keV. XL-Calibur will use the same type of mirror. The detector unit combines a low atomic number Compton scatterer with a CdZnTe detector assembly to measure the polarization making use of the fact that polarized photons Compton scatter preferentially perpendicular to the electric field orientation. It also contains a CdZnTe imager at the bottom. The detector assembly is surrounded by a BGO anticoincidence shield. The pointing system with arcsecond accuracy will be achieved by the WASP (Wallops Arc Second Pointer) from NASA's Wallops Flight Facility. A first flight of the XL-Calibur is currently foreseen for 2022, flying from Sweden.

sted, utgiver, år, opplag, sider
SPIE-Intl Soc Optical Eng, 2021
Serie
Proceedings of SPIE, ISSN 0277-786X ; 11444
Emneord
X-ray light source, X-ray generator, X-ray beamline
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-300365 (URN)10.1117/12.2560319 (DOI)000674737700046 ()2-s2.0-85099284103 (Scopus ID)
Konferanse
Conference on Space Telescopes and Instrumentation - Ultraviolet to Gamma Ray / SPIE Astronomical Telescopes + Instrumentation Conference, DEC 14-18, 2020, ELECTR NETWORK
Merknad

Part of proceedings: ISBN 978-1-5106-3676-7, QC 20230117

Tilgjengelig fra: 2021-08-31 Laget: 2021-08-31 Sist oppdatert: 2024-03-15bibliografisk kontrollert
Abarr, Q., Iyer, N. K., Kiss, M., Pearce, M. & Wilson-Hodge, C. (2020). Observations of a GX 301-2 Apastron Flare with the X-Calibur Hard X-Ray Polarimeter Supported by NICER, the Swift XRT and BAT, and Fermi GBM. Astrophysical Journal, 891(1), Article ID 70.
Åpne denne publikasjonen i ny fane eller vindu >>Observations of a GX 301-2 Apastron Flare with the X-Calibur Hard X-Ray Polarimeter Supported by NICER, the Swift XRT and BAT, and Fermi GBM
Vise andre…
2020 (engelsk)Inngår i: Astrophysical Journal, ISSN 0004-637X, E-ISSN 1538-4357, Vol. 891, nr 1, artikkel-id 70Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The accretion-powered X-ray pulsar GX 301-2 was observed with the balloon-borne X-Calibur hard X-ray polarimeter during late 2018 December, with contiguous observations by the Neutron star Interior Composition Explorer Mission (NICER) X-ray telescope, the Swift X-ray Telescope and Burst Alert Telescope, and the Fermi Gamma-ray Burst Monitor spanning several months. The observations detected the pulsar in a rare apastron flaring state coinciding with a significant spin up of the pulsar discovered with the Fermi Gamma-ray Burst Monitor. The X-Calibur, NICER, and Swift observations reveal a pulse profile strongly dominated by one main peak, and the NICER and Swift data show strong variation of the profile from pulse to pulse. The X-Calibur observations constrain for the first time the linear polarization of the 15-35 keV emission from a highly magnetized accreting neutron star, indicating a polarization degree of % (90% confidence limit) averaged over all pulse phases. We discuss the spin up and the X-ray spectral and polarimetric results in the context of theoretical predictions. We conclude with a discussion of the scientific potential of future observations of highly magnetized neutron stars with the more sensitive follow-up mission XL-Calibur.

sted, utgiver, år, opplag, sider
Institute of Physics (IOP), 2020
Emneord
Neutron stars, X-ray astronomy, Spectropolarimetry, High mass x-ray binary stars, Bianchi cosmology
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-271542 (URN)10.3847/1538-4357/ab672c (DOI)000519094300001 ()2-s2.0-85083918217 (Scopus ID)
Merknad

QC 20200427

Tilgjengelig fra: 2020-04-27 Laget: 2020-04-27 Sist oppdatert: 2024-03-15bibliografisk kontrollert
Kiss, M. (2020). Starquake ends hiatus in soft X-ray polarimetry. Nature Astronomy, 4(5), 450-451
Åpne denne publikasjonen i ny fane eller vindu >>Starquake ends hiatus in soft X-ray polarimetry
2020 (engelsk)Inngår i: Nature Astronomy, E-ISSN 2397-3366, Vol. 4, nr 5, s. 450-451Artikkel i tidsskrift, Editorial material (Fagfellevurdert) Published
sted, utgiver, år, opplag, sider
Springer Nature, 2020
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-273889 (URN)10.1038/s41550-020-1105-4 (DOI)000531917500004 ()2-s2.0-85084741311 (Scopus ID)
Merknad

QC 20240701

Tilgjengelig fra: 2020-06-01 Laget: 2020-06-01 Sist oppdatert: 2024-07-01bibliografisk kontrollert
Organisasjoner
Identifikatorer
ORCID-id: ORCID iD iconorcid.org/0000-0001-5191-9306