Endre søk
Link to record
Permanent link

Direct link
Sengupta, Sanghamitra
Publikasjoner (9 av 9) Visa alla publikasjoner
Parker, H. E., Sengupta, S., Harish, A. V., Soares, R. R. G., Jönsson, H., Margulis, W., . . . Laurell, F. (2022). A Lab-in-a-Fiber optofluidic device using droplet microfluidics and laser-induced fluorescence for virus detection. Scientific Reports, 12(1), Article ID 3539.
Åpne denne publikasjonen i ny fane eller vindu >>A Lab-in-a-Fiber optofluidic device using droplet microfluidics and laser-induced fluorescence for virus detection
Vise andre…
2022 (engelsk)Inngår i: Scientific Reports, E-ISSN 2045-2322, Vol. 12, nr 1, artikkel-id 3539Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Microfluidics has emerged rapidly over the past 20 years and has been investigated for a variety of applications from life sciences to environmental monitoring. Although continuous-flow microfluidics is ubiquitous, segmented-flow or droplet microfluidics offers several attractive features. Droplets can be independently manipulated and analyzed with very high throughput. Typically, microfluidics is carried out within planar networks of microchannels, namely, microfluidic chips. We propose that fibers offer an interesting alternative format with key advantages for enhanced optical coupling. Herein, we demonstrate the generation of monodisperse droplets within a uniaxial optofluidic Lab-in-a-Fiber scheme. We combine droplet microfluidics with laser-induced fluorescence (LIF) detection achieved through the development of an optical side-coupling fiber, which we term a periscope fiber. This arrangement provides stable and compact alignment. Laser-induced fluorescence offers high sensitivity and low detection limits with a rapid response time making it an attractive detection method for in situ real-time measurements. We use the well-established fluorophore, fluorescein, to characterize the Lab-in-a-Fiber device and determine the generation of similar to 0.9 nL droplets. We present characterization data of a range of fluorescein concentrations, establishing a limit of detection (LOD) of 10 nM fluorescein. Finally, we show that the device operates within a realistic and relevant fluorescence regime by detecting reverse-transcription loop-mediated isothermal amplification (RT-LAMP) products in the context of COVID-19 diagnostics. The device represents a step towards the development of a point- of-care droplet digital RT-LAMP platform.

sted, utgiver, år, opplag, sider
Springer Nature, 2022
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-310772 (URN)10.1038/s41598-022-07306-0 (DOI)000773009100001 ()35241725 (PubMedID)2-s2.0-85125691313 (Scopus ID)
Merknad

Correction in: Scientific Reports, Volume 12, Issue 1. DOI: 10.1038/s41598-022-09240-7, WOS: 000773009200019, Scopus: 2-s2.0-85127024135

QC 20221214

Tilgjengelig fra: 2022-04-07 Laget: 2022-04-07 Sist oppdatert: 2026-03-24bibliografisk kontrollert
Sthoer, A., Adams, E. M., Sengupta, S., Corkery, R., Allen, H. C. & Tyrode, E. (2022). La3+ and Y3+ interactions with the carboxylic acid moiety at the liquid/vapor interface: Identification of binding complexes, charge reversal, and detection limits. Journal of Colloid and Interface Science, 608, 2169-2180
Åpne denne publikasjonen i ny fane eller vindu >>La3+ and Y3+ interactions with the carboxylic acid moiety at the liquid/vapor interface: Identification of binding complexes, charge reversal, and detection limits
Vise andre…
2022 (engelsk)Inngår i: Journal of Colloid and Interface Science, ISSN 0021-9797, E-ISSN 1095-7103, Vol. 608, s. 2169-2180Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Specific interactions of yttrium and lanthanum ions with a fatty acid Langmuir monolayer were investigated using vibrational sum frequency spectroscopy. The trivalent ions were shown to interact with the charged form of the carboxylic acid group from nanomolar concentrations (<300 nM). Analysis of the spectral features from both the symmetric and the asymmetric carboxylate modes reveals the presence of at least three distinct coordination structures linked to specific binding configurations. Although the same species were identified for both La3+ and Y3+, they display a different concentration dependence, highlighting the ion-specificity of the interaction. From the analysis of the response of interfacial water molecules, the reversal of the surface charge, as well as the formation of yttrium hydroxide complexes, were detected upon increasing the amount of salt in solution. The binding interaction and kinetics of absorption are sensitive to the solution pH, showing a distinct ion speciation in the interfacial region when compared to the bulk. Changing the subphase pH or adding a monovalent background electrolyte that promotes deprotonation of the carboxylic acid headgroup could further improve the detection limit of La3+ and Y-3(+) to concentrations < 100 nM. These findings demonstrate that nM concentrations of trace metals contaminants, typically found on monovalent salts, can significantly influence the binding structure and kinetics in Langmuir monolayers.

sted, utgiver, år, opplag, sider
Elsevier BV, 2022
Emneord
Ion specific effects, Langmuir monolayer, Trivalent ions, Carboxylic acid moiety, Vibrational sum frequency spectroscopy, Molecular characterization, Carboxylate binding complexes, Charge reversal, Poisson Boltzmann theory, Vibrational spectroscopy, Arachidic acid, Eicosanoic acid monolayer
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-308570 (URN)10.1016/j.jcis.2021.10.052 (DOI)000744119500015 ()34798383 (PubMedID)2-s2.0-85118957431 (Scopus ID)
Merknad

QC 20220210

Tilgjengelig fra: 2022-02-10 Laget: 2022-02-10 Sist oppdatert: 2024-03-15bibliografisk kontrollert
Parker, H. E., Sengupta, S., Harish, A. V., Soares, R. R. G., Jönsson, H., Margulis, W., . . . Laurell, F. (2021). Digital detection and quantification of SARS-CoV-2 in a droplet microfluidic all-fiber device. In: Proceedings MicroTAS 2021 - 25th International Conference on Miniaturized Systems for Chemistry and Life Sciences: . Paper presented at 25th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2021, Palm Springs, Virtual; 10-14 October 2021 (pp. 1047-1048). Chemical and Biological Microsystems Society
Åpne denne publikasjonen i ny fane eller vindu >>Digital detection and quantification of SARS-CoV-2 in a droplet microfluidic all-fiber device
Vise andre…
2021 (engelsk)Inngår i: Proceedings MicroTAS 2021 - 25th International Conference on Miniaturized Systems for Chemistry and Life Sciences, Chemical and Biological Microsystems Society , 2021, s. 1047-1048Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Silica fibers and capillaries offer opportunities for compact integration of optics with microfluidics while adding advantages such as; flexibility within a high aspect ratio format, uniaxial arrangements, and measurement-at-a-distance. Here, we describe droplet microfluidics-based nucleic acid detection of SARS-CoV-2 in a lab-in-a-fiber platform. The fiber component integrates three modules with key functions: droplet generation, incubation, and fluorescence detection. Within the scope of this work, we developed the component specifically to target the quantification of SARS-CoV-2 viral RNA through reverse-transcription loop-mediated isothermal amplification (RT-LAMP). The all-fiber component could successfully generate uniform droplets and differentiate pre-amplified positive LAMP reaction from negative sample.

sted, utgiver, år, opplag, sider
Chemical and Biological Microsystems Society, 2021
Emneord
Digital droplet microfluidics, Fiber, Loop-mediated isothermal amplification (LAMP), Optical fiber, SARS-CoV-2, Silica fiber
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-329652 (URN)2-s2.0-85136999498 (Scopus ID)
Konferanse
25th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2021, Palm Springs, Virtual; 10-14 October 2021
Merknad

Part of ISBN 9781733419031

QC 20230614

Tilgjengelig fra: 2023-06-22 Laget: 2023-06-22 Sist oppdatert: 2025-02-10bibliografisk kontrollert
Parker, H. E., Sengupta, S., Harish, A. V., Soares, R. R. G., Jönsson, H., Margulis, W., . . . Laurell, F. (2021). Digital droplet microfluidic integrated Lab-in-a-fiber detection of SARS-CoV-2 viral RNA. In: 2021 Conference On Lasers And Electro-Optics Europe & European Quantum Electronics Conference (CLEO/EUROPE-EQEC): . Paper presented at Conference on Lasers and Electro-Optics Europe / European Quantum Electronics Conference (CLEO/Europe-EQEC), JUN 21-25, 2021, ELECTR NETWORK. Institute of Electrical and Electronics Engineers (IEEE)
Åpne denne publikasjonen i ny fane eller vindu >>Digital droplet microfluidic integrated Lab-in-a-fiber detection of SARS-CoV-2 viral RNA
Vise andre…
2021 (engelsk)Inngår i: 2021 Conference On Lasers And Electro-Optics Europe & European Quantum Electronics Conference (CLEO/EUROPE-EQEC), Institute of Electrical and Electronics Engineers (IEEE) , 2021Konferansepaper, Publicerat paper (Fagfellevurdert)
sted, utgiver, år, opplag, sider
Institute of Electrical and Electronics Engineers (IEEE), 2021
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-308804 (URN)10.1109/CLEO/Europe-EQEC52157.2021.9542752 (DOI)000728078301070 ()2-s2.0-85117567090 (Scopus ID)
Konferanse
Conference on Lasers and Electro-Optics Europe / European Quantum Electronics Conference (CLEO/Europe-EQEC), JUN 21-25, 2021, ELECTR NETWORK
Merknad

Part of proceedings: ISBN 978-1-6654-1876-8

QC 20220214

Tilgjengelig fra: 2022-02-14 Laget: 2022-02-14 Sist oppdatert: 2023-01-18bibliografisk kontrollert
Parker, H. E., Sengupta, S., Harish, A. V., Soares, R. R. G., Jönsson, H., Margulis, W., . . . Laurell, F. (2021). Digital droplet microfluidic integrated lab-in-a-fiber detection of SARS-CoV-2 viral RNA. In: Optics InfoBase Conference Papers: . Paper presented at 2021 European Conference on Lasers and Electro-Optics, CLEO/Europe 2021, 21 June 2021 through 25 June 2021. The Optical Society
Åpne denne publikasjonen i ny fane eller vindu >>Digital droplet microfluidic integrated lab-in-a-fiber detection of SARS-CoV-2 viral RNA
Vise andre…
2021 (engelsk)Inngår i: Optics InfoBase Conference Papers, The Optical Society , 2021Konferansepaper, Publicerat paper (Fagfellevurdert)
sted, utgiver, år, opplag, sider
The Optical Society, 2021
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-313441 (URN)2-s2.0-85166464482 (Scopus ID)
Konferanse
2021 European Conference on Lasers and Electro-Optics, CLEO/Europe 2021, 21 June 2021 through 25 June 2021
Merknad

QC 20220609

Part of proceedings: ISBN 978-155752820-9

Not duplicate with DiVA 1637560

Tilgjengelig fra: 2022-06-09 Laget: 2022-06-09 Sist oppdatert: 2023-08-31bibliografisk kontrollert
Parker, H. E., Sengupta, S., Harish, A. V., Soares, R. R. G., Jönsson, H., Margulis, W., . . . Laurell, F. (2021). Viral detection and quantification in a digital droplet microfluidic lab-in-a-fiber device. In: Kalli, K Mendez, A Peterka, P (Ed.), Micro-structured and specialty optical fibres VII: . Paper presented at Conference on Micro-structured and Specialty Optical Fibres VII, APR 19-23, 2021, ELECTR NETWORK. SPIE-Intl Soc Optical Eng, 11773, Article ID 117730Y.
Åpne denne publikasjonen i ny fane eller vindu >>Viral detection and quantification in a digital droplet microfluidic lab-in-a-fiber device
Vise andre…
2021 (engelsk)Inngår i: Micro-structured and specialty optical fibres VII / [ed] Kalli, K Mendez, A Peterka, P, SPIE-Intl Soc Optical Eng , 2021, Vol. 11773, artikkel-id 117730YKonferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

In this work, we present the design and fabrication of a fiber device that performs digital droplet microfluidics for molecular diagnostics. A variety of fibers and capillaries were used to build three connected modules dedicated to droplet generation, incubation, and fluorescence detection which enables a uniaxial arrangement. This is in contrast to the traditional 2-dimensional lab-on-a-chip architecture. We characterize our fiber device using a fluorescein dilution series. Our observed detection limit is on the order of 10 nM fluorescein. We demonstrate our all-fiber device for the fluorescence readout after loop-mediated isothermal amplification (LAMP) of synthetic SARS-CoV-2. Our results suggest that this fiber device can successfully distinguish between positive and negative samples in molecular diagnostics. We propose that our fiber device offers benefits over microfluidic chip techniques such as easier optical integration, much simpler sample loading, and faster diagnosis with high specificity and sensitivity.

sted, utgiver, år, opplag, sider
SPIE-Intl Soc Optical Eng, 2021
Serie
Proceedings of SPIE, ISSN 0277-786X
Emneord
All-fiber device, microfluidics, optofluidics, loop-mediated isothermal amplification (LAMP), molecular diagnostics, SARS-CoV2
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-303179 (URN)10.1117/12.2590850 (DOI)000696183900019 ()2-s2.0-85109212481 (Scopus ID)
Konferanse
Conference on Micro-structured and Specialty Optical Fibres VII, APR 19-23, 2021, ELECTR NETWORK
Merknad

Part of proceedings, ISBN 978-1-5106-4381-9, QC 20230117

Tilgjengelig fra: 2021-10-11 Laget: 2021-10-11 Sist oppdatert: 2025-02-20bibliografisk kontrollert
Tyrode, E., Sengupta, S. & Sthoer, A. (2020). Identifying Eigen-like hydrated protons at negatively charged interfaces. Nature Communications, 11(1), Article ID 493.
Åpne denne publikasjonen i ny fane eller vindu >>Identifying Eigen-like hydrated protons at negatively charged interfaces
2020 (engelsk)Inngår i: Nature Communications, E-ISSN 2041-1723, Vol. 11, nr 1, artikkel-id 493Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Despite the importance of the hydrogen ion in a wide range of biological, chemical, and physical processes, its molecular structure in solution remains lively debated. Progress has been primarily hampered by the extreme diffuse nature of the vibrational signatures of hydrated protons in bulk solution. Using the inherently surface-specific vibrational sum frequency spectroscopy technique, we show that at selected negatively charged interfaces, a resolved spectral feature directly linked to the H3O+ core in an Eigen-like species can be readily identified in a biologically compatible pH range. Centered at ~2540 cm−1, the band is seen to shift to ~1875 cm−1 when forming D3O+ upon isotopic substitution. The results offer the possibility of tracking and understanding from a molecular perspective the behavior of hydrated protons at charged interfaces.

sted, utgiver, år, opplag, sider
Nature Research, 2020
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-267766 (URN)10.1038/s41467-020-14370-5 (DOI)000526549400001 ()31980619 (PubMedID)2-s2.0-85078269817 (Scopus ID)
Merknad

QC 20200602

Tilgjengelig fra: 2020-02-19 Laget: 2020-02-19 Sist oppdatert: 2023-03-28bibliografisk kontrollert
Sengupta, S., Moberg, D. R., Paesani, F. & Tyrode, E. (2018). Neat Water-Vapor Interface: Proton Continuum and the Nonresonant Background. The Journal of Physical Chemistry Letters, 9(23), 6744-6749
Åpne denne publikasjonen i ny fane eller vindu >>Neat Water-Vapor Interface: Proton Continuum and the Nonresonant Background
2018 (engelsk)Inngår i: The Journal of Physical Chemistry Letters, E-ISSN 1948-7185, Vol. 9, nr 23, s. 6744-6749Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Whether the surface of neat water is "acidic" or "basic" remains an active and controversial field of research. Most of the experimental evidence supporting the preferential adsorption of H3O+ ions stems from nonlinear optical spectroscopy methods typically carried out at extreme pH conditions (pH < 1). Here, we use vibrational sum frequency spectroscopy (VSFS) to target the "proton continuum", an unexplored frequency range characteristic of hydrated protons and hydroxide ions. The VSFS spectra of neat water show a broad and nonzero signal intensity between 1700 and 3000 cm-' in the three different polarization combinations examined. By comparing the SF response of water with that from dilute HCl and NaOH aqueous solutions, we conclude the intensity does not originate from either adsorbed H3O+ or OH- ions. Contributions from the nonresonant background are then critically considered by comparing the experimental results with many-body molecular dynamics (MB-MD) simulated spectra.

sted, utgiver, år, opplag, sider
American Chemical Society (ACS), 2018
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-240731 (URN)10.1021/acs.jpclett.8b03069 (DOI)000452929200012 ()30407831 (PubMedID)2-s2.0-85058092810 (Scopus ID)
Merknad

QC 20180109

Tilgjengelig fra: 2019-01-09 Laget: 2019-01-09 Sist oppdatert: 2024-07-04bibliografisk kontrollert
Sthoer, A., Adams, E., Sengupta, S., Corkery, R., Allen, H. & Tyrode, E.La3+ and Y3+ interactions with the carboxylic acid moiety at theliquid/vapor interface: identification of binding complexes, chargereversal, and detection limits..
Åpne denne publikasjonen i ny fane eller vindu >>La3+ and Y3+ interactions with the carboxylic acid moiety at theliquid/vapor interface: identification of binding complexes, chargereversal, and detection limits.
Vise andre…
(engelsk)Manuskript (preprint) (Annet vitenskapelig)
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-256569 (URN)
Merknad

Part of a thesis

QC 20190906

Tilgjengelig fra: 2019-08-28 Laget: 2019-08-28 Sist oppdatert: 2022-10-24bibliografisk kontrollert
Organisasjoner