kth.sePublications KTH
System disruptions
There are recurring service disruptions on some of the search portals due to high traffic. We are working to resolve the issue, you may temporarily encounter an error message.
Change search
Link to record
Permanent link

Direct link
Parfeniukas, KarolisORCID iD iconorcid.org/0000-0001-7569-9408
Publications (9 of 9) Show all publications
Bjorling, A., Kalbfleisch, S., Kahnt, M., Sala, S., Parfeniukas, K., Vogt, U., . . . Johansson, U. (2020). Ptychographic characterization of a coherent nanofocused X-ray beam. Optics Express, 28(4), 5069-5076
Open this publication in new window or tab >>Ptychographic characterization of a coherent nanofocused X-ray beam
Show others...
2020 (English)In: Optics Express, E-ISSN 1094-4087, Vol. 28, no 4, p. 5069-5076Article in journal (Refereed) Published
Abstract [en]

The NanoMAX hard X-ray nanoprobe is the first beamline to take full advantage of the diffraction-limited storage ring at the MAX IV synchrotron and delivers a high coherent photon flux for applications in diffraction and imaging. Here, we characterize its coherent and focused beam using ptychographic analysis. We derive beam profiles in the energy range 6-22 keV and estimate the coherent flux based on a probe mode decomposition approach.

Place, publisher, year, edition, pages
OPTICAL SOC AMER, 2020
National Category
Physical Sciences
Identifiers
urn:nbn:se:kth:diva-271942 (URN)10.1364/OE.386068 (DOI)000514575500062 ()32121735 (PubMedID)2-s2.0-85079351442 (Scopus ID)
Note

QC 20200415

Available from: 2020-04-15 Created: 2020-04-15 Last updated: 2022-09-15Bibliographically approved
Akan, R., Parfeniukas, K., Vogt, C., Toprak, M. & Vogt, U. (2018). Investigation of Metal-Assisted Chemical Etching for Fabrication of Silicon-Based X-Ray Zone Plates. Paper presented at 14th International Conference on X-ray Microscopy (XRM2018), Saskatoon, August 19 - 24, 2018. Microscopy and Microanalysis
Open this publication in new window or tab >>Investigation of Metal-Assisted Chemical Etching for Fabrication of Silicon-Based X-Ray Zone Plates
Show others...
2018 (English)In: Microscopy and Microanalysis, ISSN 1431-9276, E-ISSN 1435-8115Article in journal, Meeting abstract (Refereed) Published
National Category
Other Physics Topics Atom and Molecular Physics and Optics
Research subject
Physics, Optics and Photonics; Physics, Material and Nano Physics
Identifiers
urn:nbn:se:kth:diva-292563 (URN)
Conference
14th International Conference on X-ray Microscopy (XRM2018), Saskatoon, August 19 - 24, 2018
Note

QC 20210414

Available from: 2021-04-08 Created: 2021-04-08 Last updated: 2022-06-25Bibliographically approved
Akan, R., Parfeniukas, K., Vogt, C., Toprak, M. S. & Vogt, U. (2018). Reaction control of metal-assisted chemical etching for silicon-based zone plate nanostructures. RSC Advances, 8(23), 12628-12634
Open this publication in new window or tab >>Reaction control of metal-assisted chemical etching for silicon-based zone plate nanostructures
Show others...
2018 (English)In: RSC Advances, E-ISSN 2046-2069, Vol. 8, no 23, p. 12628-12634Article in journal (Refereed) Published
Abstract [en]

Metal-assisted chemical etching (MACE) reaction parameters were investigated for the fabrication of specially designed silicon-based X-ray zone plate nanostructures using a gold catalyst pattern and etching solutions composed of HF and H2O2. Etching depth, zone verticality and zone roughness were studied as a function of etching solution composition, temperature and processing time. Homogeneous, vertical etching with increasing depth is observed at increasing H2O2 concentrations and elevated processing temperatures, implying a balance in the hole injection and silica dissolution kinetics at the gold-silicon interface. The etching depth decreases and zone roughness increases at the highest investigated H2O2 concentration and temperature. Possible reasons for these observations are discussed based on reaction chemistry and zone plate design. Optimum MACE conditions are found at HFH2O2 concentrations of 4.7 M:0.68 M and room temperature with an etching rate of ≈0.7 μm min-1, which is about an order of magnitude higher than previous reports. Moreover, our results show that a grid catalyst design is important for successful fabrication of vertical high aspect ratio silicon nanostructures. 

Place, publisher, year, edition, pages
Royal Society of Chemistry, 2018
Keywords
Aspect ratio, Charge injection, Hydrofluoric acid, Nanocatalysts, Nanostructures, Plate metal, Processing, Silica, Silicon, X ray diffraction, Etching solutions, Metal-assisted chemical etching, Processing temperature, Reaction chemistry, Reaction parameters, Silica dissolution, Silicon interface, Silicon nano structures, Etching
National Category
Condensed Matter Physics
Identifiers
urn:nbn:se:kth:diva-227483 (URN)10.1039/c8ra01627e (DOI)000429450000016 ()35541233 (PubMedID)2-s2.0-85045188242 (Scopus ID)
Funder
Swedish Research Council
Note

Export Date: 9 May 2018; Article; CODEN: RSCAC; Correspondence Address: Vogt, U.; KTH Royal Institute of Technology, Department of Applied Physics, Biomedical and X-ray Physics, Albanova University CenterSweden; email: uvogt@kth.se; Funding details: VR, Vetenskapsrådet; Funding text: This work was supported by the Swedish Research Council. We thank Adem B. Ergul for help with the cross-section images and Jussi Rahomäki for starting with MACE in our group. QC 20180516

Available from: 2018-05-16 Created: 2018-05-16 Last updated: 2024-03-18Bibliographically approved
Seiboth, F., Schropp, A., Scholz, M., Wittwer, F., Roedel, C., Wuensche, M., . . . Schroer, C. G. (2017). Aberration Correction for Hard X-ray Focusing at the Nanoscale. In: Morawe, C Khounsary, AM Goto, S (Ed.), Advances in X-Ray/EUV Optics and Components XII: . Paper presented at Conference on Advances in XRay/ EUV Optics and Components XII held as part of the SPIE Optics + Photonics Symposium, AUG 08-09, 2017, San Diego, CA. SPIE - International Society for Optical Engineering, Article ID UNSP 103860A.
Open this publication in new window or tab >>Aberration Correction for Hard X-ray Focusing at the Nanoscale
Show others...
2017 (English)In: Advances in X-Ray/EUV Optics and Components XII / [ed] Morawe, C Khounsary, AM Goto, S, SPIE - International Society for Optical Engineering, 2017, article id UNSP 103860AConference paper, Published paper (Refereed)
Abstract [en]

We developed a corrective phase plate that enables the correction of residual aberration in reflective, diffractive, and refractive X-ray optics. The principle is demonstrated on a stack of beryllium compound refractive lenses with a numerical aperture of 0.49 x 10(-3) at three different synchrotron radiation and x-ray free-electron laser facilities. By introducing this phase plate into the beam path, we were able to correct the spherical aberration of the optical system and improve the Strehl ratio of the optics from 0.29(7) to 0.87(5), creating a diffraction-limited, large aperture, nanofocusing optics that is radiation resistant and very compact.

Place, publisher, year, edition, pages
SPIE - International Society for Optical Engineering, 2017
Series
Proceedings of SPIE, ISSN 0277-786X ; 10386
Keywords
x-ray optics, compound refractive lenses, aberration correction, ptychography, wavefront sensing
National Category
Other Physics Topics
Identifiers
urn:nbn:se:kth:diva-220504 (URN)10.1117/12.2274030 (DOI)000417334200008 ()2-s2.0-85038942600 (Scopus ID)978-1-5106-1230-3 (ISBN)978-1-5106-1229-7 (ISBN)
Conference
Conference on Advances in XRay/ EUV Optics and Components XII held as part of the SPIE Optics + Photonics Symposium, AUG 08-09, 2017, San Diego, CA
Note

QC 20171222

Available from: 2017-12-22 Created: 2017-12-22 Last updated: 2024-03-15Bibliographically approved
Vogt, U., Parfeniukas, K., Stankevic, T., Kalbfleisch, S., Liebi, M., Matej, Z., . . . Johansson, U. (2017). First x-ray nanoimaging experiments at NanoMAX. In: Lai, B Somogyi, A (Ed.), X-Ray Nanoimaging: Instruments and Methods III 2017. Paper presented at X-Ray Nanoimaging: Instruments and Methods III 2017, San Diego, United States, 7 August 2017 through 8 August 2017. SPIE - The International Society for Optics and Photonics, 10389, Article ID 103890K.
Open this publication in new window or tab >>First x-ray nanoimaging experiments at NanoMAX
Show others...
2017 (English)In: X-Ray Nanoimaging: Instruments and Methods III 2017 / [ed] Lai, B Somogyi, A, SPIE - The International Society for Optics and Photonics, 2017, Vol. 10389, article id 103890KConference paper, Published paper (Refereed)
Abstract [en]

NanoMAX is a hard x-ray nanoimaging beamline at the new Swedish synchrotron radiation source MAX IV that became operational in 2016. Being a beamline dedicated to x-ray nanoimaging in both 2D and 3D, NanoMAX is the first to take full advantage of MAX IVs exceptional low emittance and resulting coherent properties. We present results from the first experiments at NanoMAX that took place in December 2016. These did not use the final experimental stations that will become available to users, but a temporary arrangement including zone plate and order-sorting aperture stages and a piezo-driven sample scanner. We used zone plates with outermost zone widths of 100 nm and 30 nm and performed experiments at 8 keV photon energy for x-ray absorption and fluorescence imaging and ptychography. Moreover, we investigated stability and coherence with a Ronchi test method. Despite the rather simple setup, we could demonstrate spatial resolution below 50 nm after only a few hours of beamtime. The results showed that the beamline is working as expected and experiments approaching the 10 nm resolution level or below should be possible in the future.

Place, publisher, year, edition, pages
SPIE - The International Society for Optics and Photonics, 2017
Series
Proceedings of SPIE, ISSN 0277-786X ; 10389
Keywords
X-ray microscopy, x-ray nanoimaging, x-ray zone plates
National Category
Other Physics Topics
Identifiers
urn:nbn:se:kth:diva-220505 (URN)10.1117/12.2272960 (DOI)000417335200006 ()2-s2.0-85034272848 (Scopus ID)
Conference
X-Ray Nanoimaging: Instruments and Methods III 2017, San Diego, United States, 7 August 2017 through 8 August 2017
Funder
Swedish Research Council
Note

QC 20241106

Part of ISBN 978-1-5106-1236-5, 978-1-5106-1235-8

Available from: 2017-12-22 Created: 2017-12-22 Last updated: 2024-11-06Bibliographically approved
Parfeniukas, K., Giakoumidis, S., Akan, R. & Vogt, U. (2017). High-aspect ratio zone plate fabrication for hard x-ray nanoimaging. In: Morawe, C Khounsary, AM Goto, S (Ed.), Advances in X-Ray/EUV Optics and Components XII: . Paper presented at Conference on Advances in XRay/ EUV Optics and Components XII held as part of the SPIE Optics + Photonics Symposium, AUG 08-09, 2017, San Diego, CA. SPIE - The International Society for Optics and Photonics, 10386, Article ID UNSP 103860S.
Open this publication in new window or tab >>High-aspect ratio zone plate fabrication for hard x-ray nanoimaging
2017 (English)In: Advances in X-Ray/EUV Optics and Components XII / [ed] Morawe, C Khounsary, AM Goto, S, SPIE - The International Society for Optics and Photonics, 2017, Vol. 10386, article id UNSP 103860SConference paper, Published paper (Refereed)
Abstract [en]

We present our results in fabricating Fresnel zone plate optics for the NanoMAX beamline at the fourth-generation synchrotron radiation facility MAX IV, to be used in the energy range of 6-10 keV. The results and challenges of tungsten nanofabrication are discussed, and an alternative approach using metal-assisted chemical etching (MACE) of silicon is showcased. We successfully manufactured diffraction-limited zone plates in tungsten with 30 nm outermost zone width and an aspect ratio of 21:1. These optics were used for nanoimaging experiments at NanoMAX. However, we found it challenging to further improve resolution and diffraction efficiency using tungsten. High efficiency is desirable to fully utilize the advantage of increased coherence on the optics at MAX IV. Therefore, we started to investigate MACE of silicon for the nanofabrication of high-resolution and high-efficiency zone plates. The first type of structures we propose use the silicon directly as the phase-shifting material. We have achieved 6 mu m deep dense vertical structures with 100 nm linewidth. The second type of optics use iridium as the phase material. The structures in the silicon substrate act as a mold for iridium coating via atomic layer deposition (ALD). A semi-dense pattern is used with line-to-space ratio of 1:3 for a so-called frequency-doubled zone plate. This way, it is possible to produce smaller structures with the tradeoff of the additional ALD step. We have fabricated 45 nm-wide and 3.6 mu m-tall silicon/iridium structures.

Place, publisher, year, edition, pages
SPIE - The International Society for Optics and Photonics, 2017
Series
Proceedings of SPIE, ISSN 0277-786X ; 10386
Keywords
zone plate, high-aspect ratio, etching, RIE, MACE, tungsten, silicon, gold
National Category
Other Physics Topics
Identifiers
urn:nbn:se:kth:diva-220503 (URN)10.1117/12.2272695 (DOI)000417334200016 ()2-s2.0-85038958242 (Scopus ID)
Conference
Conference on Advances in XRay/ EUV Optics and Components XII held as part of the SPIE Optics + Photonics Symposium, AUG 08-09, 2017, San Diego, CA
Funder
Swedish Research Council, C0242401Knut and Alice Wallenberg Foundation
Note

QC 20241106

Part of ISBN 978-151061229-7

Available from: 2017-12-22 Created: 2017-12-22 Last updated: 2024-11-06Bibliographically approved
Vogt, U., Köhler, D., Dickmann, J., Rahomäki, J., Parfeniukas, K., Kubsky, S., . . . Stankevič, T. (2017). Moiré method for nanometer instability investigation of scanning hard x-ray microscopes. Optics Express, 25(11), 12188-12194
Open this publication in new window or tab >>Moiré method for nanometer instability investigation of scanning hard x-ray microscopes
Show others...
2017 (English)In: Optics Express, E-ISSN 1094-4087, Vol. 25, no 11, p. 12188-12194Article in journal (Refereed) Published
Abstract [en]

We present a Moiré method that can be used to investigate positional instabilities in a scanning hard x-ray microscope with nanometer precision. The development of diffractionlimited storage rings offering highly-brilliant synchrotron radiation and improvements of nanofocusing x-ray optics paves the way towards 3D nanotomography with 10 nm resolution or below. However, this trend demands improved designs of x-ray microscope instruments which should offer few-nm beam stabilities with respect to the sample. Our technique can measure the position of optics and sample stage relative to each other in the two directions perpendicular to the beam propagation in a scanning x-ray microscope using simple optical components and visible light. The usefulness of the method was proven by measuring short and long term instabilities of a zone-plate-optics-based prototype microscope. We think it can become an important tool for the characterization of scanning x-ray microscopes, especially prior to experiments with an actual x-ray beam.

Place, publisher, year, edition, pages
Optical Society of America, 2017
National Category
Other Physics Topics
Identifiers
urn:nbn:se:kth:diva-209609 (URN)10.1364/OE.25.012188 (DOI)000403940700013 ()28786577 (PubMedID)2-s2.0-85019983867 (Scopus ID)
Note

QC 20170621

Available from: 2017-06-21 Created: 2017-06-21 Last updated: 2024-03-15Bibliographically approved
Seiboth, F., Schropp, A., Scholz, M., Wittwer, F., Rödel, C., Wünsche, M., . . . Schroer, C. G. (2017). Perfect X-ray focusing via fitting corrective glasses to aberrated optics. Nature Communications, 8
Open this publication in new window or tab >>Perfect X-ray focusing via fitting corrective glasses to aberrated optics
Show others...
2017 (English)In: Nature Communications, E-ISSN 2041-1723, Vol. 8Article in journal (Refereed) Published
Abstract [en]

Due to their short wavelength, X-rays can in principle be focused down to a few nanometres and below. At the same time, it is this short wavelength that puts stringent requirements on X-ray optics and their metrology. Both are limited by today’s technology. In this work, we present accurate at wavelength measurements of residual aberrations of a refractive X-ray lens using ptychography to manufacture a corrective phase plate. Together with the fitted phase plate the optics shows diffraction-limited performance, generating a nearly Gaussian beam profile with a Strehl ratio above 0.8. This scheme can be applied to any other focusing optics, thus solving the X-ray optical problem at synchrotron radiation sources and X-ray free-electron lasers.

Place, publisher, year, edition, pages
Nature Publishing Group, 2017
Keywords
Imaging and sensing, Microscopy, X-rays
National Category
Other Physics Topics
Identifiers
urn:nbn:se:kth:diva-203619 (URN)10.1038/ncomms14623 (DOI)000395053700001 ()28248317 (PubMedID)2-s2.0-85014451131 (Scopus ID)
Note

QC 20170316

Available from: 2017-03-16 Created: 2017-03-16 Last updated: 2024-03-15Bibliographically approved
Parfeniukas, K., Rahomäki, J., Giakoumidis, S., Seiboth, F., Wittwer, F., Schroer, C. G. & Vogt, U. (2016). Improved tungsten nanofabrication for hard X-ray zone plates. Microelectronic Engineering, 152, 6-9
Open this publication in new window or tab >>Improved tungsten nanofabrication for hard X-ray zone plates
Show others...
2016 (English)In: Microelectronic Engineering, ISSN 0167-9317, E-ISSN 1873-5568, Vol. 152, p. 6-9Article in journal (Refereed) Published
Abstract [en]

We present an improved nanofabrication method of high aspect ratio tungsten structures for use in high efficiency nanofocusing hard X-ray zone plates. A ZEP 7000 electron beam resist layer used for patterning is cured by a second, much larger electron dose after development. The curing step improves pattern transfer fidelity into a chromium hard mask by reactive ion etching using Cl2/O2 chemistry. The pattern can then be transferred into an underlying tungsten layer by another reactive ion etching step using SF6/O2. A 630 nm-thick tungsten zone plate with smallest line width of 30 nm was fabricated using this method and characterized. At 8.2 keV photon energy the device showed an efficiency of 2.2% with a focal spot size at the diffraction limit, measured at Diamond Light Source I-13-1 beamline.

Keywords
High aspect ratio, Reactive ion etching, Tungsten, X-ray diffractive optics, Zone plate
National Category
Atom and Molecular Physics and Optics
Identifiers
urn:nbn:se:kth:diva-180917 (URN)10.1016/j.mee.2015.12.015 (DOI)000385991400002 ()2-s2.0-84952359520 (Scopus ID)
Note

QC 20160128

Available from: 2016-01-28 Created: 2016-01-25 Last updated: 2022-06-23Bibliographically approved
Organisations
Identifiers
ORCID iD: ORCID iD iconorcid.org/0000-0001-7569-9408

Search in DiVA

Show all publications