kth.sePublications KTH
Change search
Link to record
Permanent link

Direct link
Somesfalean, Gabriel
Publications (10 of 17) Show all publications
Mei, L., Svanberg, S. & Somesfalean, G. (2013). Frequency-modulated light scattering in colloidal suspensions. Applied Physics Letters, 102(6), 061104
Open this publication in new window or tab >>Frequency-modulated light scattering in colloidal suspensions
2013 (English)In: Applied Physics Letters, ISSN 0003-6951, E-ISSN 1077-3118, Vol. 102, no 6, p. 061104-Article in journal (Refereed) Published
Abstract [en]

Frequency-modulated light field fluctuations due to moving particles in colloidal suspensions are examined using heterodyne interferometry. The power spectrum is the combined result of a time-of-flight-related frequency distribution due to light scattering and frequency shifts due to the Doppler effect. An approximation model is developed based on diffusion theory and verified experimentally. The potential for application towards comprehensive diagnosis of both particle dynamics and optical properties of the examined media is discussed.

Place, publisher, year, edition, pages
AIP Publishing, 2013
Keywords
Diffusing-Wave Spectroscopy, Random-Media, Diode-Laser, Transition
National Category
Physical Sciences
Identifiers
urn:nbn:se:kth:diva-119457 (URN)10.1063/1.4792220 (DOI)000315053300004 ()2-s2.0-84874271108 (Scopus ID)
Funder
Swedish Research Council, 621-2011-4265
Note

Correction in: Applied Physics Letters, vol. 102, issue. 10. DOI: 10.1063/1.4795242, WOS:000316501200098

QC 20130318

Available from: 2013-03-18 Created: 2013-03-14 Last updated: 2024-03-15Bibliographically approved
Lou, X., Somesfalean, G., Zhang, Z. & Wu, S. (2013). Temperature-Corrected Oxygen Detection Based on Multi-Mode Diode Laser Correlation Spectroscopy. Journal of Spectroscopy, 2013, 1-8
Open this publication in new window or tab >>Temperature-Corrected Oxygen Detection Based on Multi-Mode Diode Laser Correlation Spectroscopy
2013 (English)In: Journal of Spectroscopy, ISSN 2314-4920, Vol. 2013, p. 1-8Article in journal (Refereed) Published
Abstract [en]

Temperature-corrected oxygen measurements were performed by using multi-mode diode laser correlation spectroscopy at temperatures ranging between 300 and 473 K. The experiments simulate in situ monitoring of oxygen in coal-combustion exhaust gases at the tail of the flue. A linear relationship with a correlation coefficient of -0.999 was found between the evaluated concentration and the gas temperature. Temperature effects were either auto-corrected by keeping the reference gas at the same conditions as the sample gas, or rectified by using a predetermined effective temperature-correction coefficient calibrated for a range of absorption wavelengths. Relative standard deviations of the temperature-correction coefficient calibrated for a range of absorption wavelengths. Relative standard deviations of the temperature-corrected oxygen concentrations obtained by different schemes and at various temperatures were estimated, yielding a measurement precision of 0.6%.

Place, publisher, year, edition, pages
Hindawi Limited, 2013
Keywords
Modulation Spectroscopy, Gas Control, Sensors, Dioxide
National Category
Biochemistry Molecular Biology
Identifiers
urn:nbn:se:kth:diva-107603 (URN)10.1155/2013/524071 (DOI)000311152800001 ()2-s2.0-84876937833 (Scopus ID)
Funder
Swedish Research Council, 621-2011-4265
Note

QC 20121214

Available from: 2012-12-14 Created: 2012-12-14 Last updated: 2025-02-20Bibliographically approved
Mei, L., Guan, Z. G., Zhou, H. J., Lv, J., Zhu, Z. R., Cheng, J. A., . . . Somesfalean, G. (2012). Agricultural pest monitoring using fluorescence lidar techniques Feasibility study. Applied physics. B, Lasers and optics (Print), 106(3), 733-740
Open this publication in new window or tab >>Agricultural pest monitoring using fluorescence lidar techniques Feasibility study
Show others...
2012 (English)In: Applied physics. B, Lasers and optics (Print), ISSN 0946-2171, E-ISSN 1432-0649, Vol. 106, no 3, p. 733-740Article in journal (Refereed) Published
Abstract [en]

The fluorescence of different types of planthopper (Hemiptera) and moth (Lepidoptera), which constitute important Chinese agricultural pests, was investigated both in situ in a laboratory setting and remotely using a fluorescence light detection and ranging (lidar) system operating at a range of about 50 m. The natural autofluorescence of different species, as well as the fluorescence from insects that had been dusted with fluorescent dye powder for identification were studied. Autofluorescence spectra of both moths and planthoppers show a maximum intensity peak around 450 nm. Bleaching upon long-time laser illumination was modest and did not affect the shape of the spectrum. A single dyed rice planthopper, a few mm in size, could be detected at 50 m distance by using the fluorescence lidar system. By employing various marking dyes, different types of agricultural pest could be determined. We suggest that lidar may be used in studies of migration and movement of pest insects, including studies of their behavior in the vicinity of pheromone traps and in pheromone-treated fields.

National Category
Physical Sciences
Identifiers
urn:nbn:se:kth:diva-91611 (URN)10.1007/s00340-011-4785-8 (DOI)000300733900032 ()2-s2.0-84859711926 (Scopus ID)
Note

QC 20120329

Available from: 2012-03-29 Created: 2012-03-19 Last updated: 2024-03-15Bibliographically approved
Zhang, Y. G., Somesfalean, G., Guo, W., Wang, H. S., Wu, S. H., Qin, Y. K. & Zhang, Z. G. (2012). An optical system for measuring nitric oxide using spectral separation techniques. Applied physics. B, Lasers and optics (Print), 107(2), 435-440
Open this publication in new window or tab >>An optical system for measuring nitric oxide using spectral separation techniques
Show others...
2012 (English)In: Applied physics. B, Lasers and optics (Print), ISSN 0946-2171, E-ISSN 1432-0649, Vol. 107, no 2, p. 435-440Article in journal (Refereed) Published
Abstract [en]

An optical sensor based on differential absorption spectroscopy for real-time monitoring of industrial nitric oxide (NO) gas emission is described. The influence of gas absorption interference from sulfur dioxide (SO2) in the environment was considered and a spectral separation technique was developed in order to eliminate this interference effect. The absorption spectrum of SO2 around 226 nm was evaluated by the SO2 concentration obtained using the experimentally recorded absorption spectrum around 300 nm. The absorption spectrum of NO around 226 nm was obtained by subtracting the absorption of SO2 from the integral absorption spectrum of SO2 and NO. The concentration measurements were performed at atmospheric pressure. The technique was found to have a lower detection limit of 0.8 ppm for NO per meter path length (SNR=2) and be immune from the influence from SO2 on the NO measurement. The sensor based on this technique was successfully employed for in situ measurement of SO2 and NO concentrations in the flue gas emitted from an industrial coal-fired boiler.

Keywords
Air-Pollution, Gas-Detection, Doas System, Sensor, Laser, Emissions, Analyzer, Cell
National Category
Physical Sciences
Identifiers
urn:nbn:se:kth:diva-98014 (URN)10.1007/s00340-012-4965-1 (DOI)000304166900026 ()2-s2.0-84861814192 (Scopus ID)
Note
QC 20120619Available from: 2012-06-19 Created: 2012-06-18 Last updated: 2024-03-18Bibliographically approved
Mei, L., Lundin, P., Andersson-Engels, S., Svanberg, S. & Somesfalean, G.-G. (2012). Characterization and validation of the frequency-modulated continuous-wave technique for assessment of photon migration in solid scattering media. Applied physics. B, Lasers and optics (Print), 109(3), 467-475
Open this publication in new window or tab >>Characterization and validation of the frequency-modulated continuous-wave technique for assessment of photon migration in solid scattering media
Show others...
2012 (English)In: Applied physics. B, Lasers and optics (Print), ISSN 0946-2171, E-ISSN 1432-0649, Vol. 109, no 3, p. 467-475Article in journal (Refereed) Published
Abstract [en]

The frequency-modulated continuous-wave (FM-CW) technique, based on the beat signal of a Mach-Zehnder interferometer employing a frequency-ramped light source, is studied for solid scattering media applications. The method is used to evaluate the mean time-of-flight (MTOF) of light traveling in scattering media, specifically polystyrene foams. We assume that each the time-of-flight (TOF) time corresponds to different light scattering paths resulting in a different phase shift. The phase shift variations produce a speckle pattern, which together with the frequency leakage induced by the discrete Fourier transform (DFT) cause "spikes" in the power spectrum of the beat signal, thus decreasing the accuracy of the measured MTOF values in solid scattering media. For comparison, time-of-flight spectroscopy (TOFS) is also employed to evaluate the MTOF for the same samples, while the geometrical difference between these two techniques is compensated for by using diffusion theory. The MTOFs measured by the FMCW and TOFS techniques agree well, which demonstrates a great potential to develop a robust FMCW setup for simplified MTOF assessment.

Place, publisher, year, edition, pages
Springer Nature, 2012
National Category
Atom and Molecular Physics and Optics
Identifiers
urn:nbn:se:kth:diva-303595 (URN)10.1007/s00340-012-5103-9 (DOI)000312081700013 ()2-s2.0-84875915793 (Scopus ID)
Note

QC 20211021

Available from: 2021-10-21 Created: 2021-10-21 Last updated: 2024-03-18Bibliographically approved
Mei, L., Svanberg, S. & Somesfalean, G. (2012). Combined optical porosimetry and gas absorption spectroscopy in gas-filled porous media using diode-laser-based frequency domain photon migration. Optics Express, 20(15), 16942-16954
Open this publication in new window or tab >>Combined optical porosimetry and gas absorption spectroscopy in gas-filled porous media using diode-laser-based frequency domain photon migration
2012 (English)In: Optics Express, E-ISSN 1094-4087, Vol. 20, no 15, p. 16942-16954Article in journal (Refereed) Published
Abstract [en]

A combination method of frequency domain photon migration (FDPM) and gas in scattering media absorption spectroscopy (GASMAS) is used for assessment of the mean optical path length (MOPL) and the gas absorption in gas-filled porous media, respectively. Polystyrene (PS) foams, with extremely high physical porosity, are utilized as sample materials for proof-of-principle demonstration. The optical porosity, defined as the ratio between the path length through the pores and the path length through the medium, is evaluated in PS foam and found consistent with the measured physical porosity. The method was also utilized for the study of balsa and spruce wood samples.

Keywords
Combination method, Frequency domain photon migration, Mean optical path length, Path length, Porosimetry, Proof of principles, Scattering media, Spruce wood
National Category
Other Physics Topics
Identifiers
urn:nbn:se:kth:diva-104263 (URN)10.1364/OE.20.016942 (DOI)000307055800079 ()2-s2.0-84864151318 (Scopus ID)
Funder
Swedish Research Council, 621-2011-4265
Note

QC 20121106

Available from: 2012-11-06 Created: 2012-10-31 Last updated: 2024-03-15Bibliographically approved
Lou, X., Somesfalean, G., Svanberg, S., Zhang, Z. & Wu, S. (2012). Detection of elemental mercury by multimode diode laser correlation spectroscopy. Optics Express, 20(5), 4927-4938
Open this publication in new window or tab >>Detection of elemental mercury by multimode diode laser correlation spectroscopy
Show others...
2012 (English)In: Optics Express, E-ISSN 1094-4087, Vol. 20, no 5, p. 4927-4938Article in journal (Refereed) Published
Abstract [en]

We demonstrate a method for elemental mercury detection based on correlation spectroscopy employing UV laser radiation generated by sum-frequency mixing of two visible multimode diode lasers. Resonance matching of the multimode UV laser is achieved in a wide wavelength range and with good tolerance for various operating conditions. Large mode-hops provide an off-resonance baseline, eliminating interferences from other gas species with broadband absorption. A sensitivity of 1 mu g/m(3) is obtained for a 1-m path length and 30-s integration time. The performance of the system shows promise for mercury monitoring in industrial applications.

National Category
Other Physics Topics
Identifiers
urn:nbn:se:kth:diva-92342 (URN)10.1364/OE.20.004927 (DOI)000301053200012 ()22418298 (PubMedID)2-s2.0-84857541955 (Scopus ID)
Note
QC 20120418Available from: 2012-04-18 Created: 2012-04-02 Last updated: 2024-03-15Bibliographically approved
Lundin, P., Svanberg, E. K., Somesfalean, G., Soltanolkotabi, M., Cocola, L., Lewander, M., . . . Svanberg, S. (2012). Gas Monitoring in Human Body Cavities Using Non-Intrusive Diode Laser Absorption Spectroscopy. In: 2012 Asia Communications And Photonics Conference (Acp): . Paper presented at Asia Communications and Photonics Conference (ACP), NOV 07-10, 2012, Guangzhou, PEOPLES R CHINA. IEEE
Open this publication in new window or tab >>Gas Monitoring in Human Body Cavities Using Non-Intrusive Diode Laser Absorption Spectroscopy
Show others...
2012 (English)In: 2012 Asia Communications And Photonics Conference (Acp), IEEE , 2012Conference paper, Published paper (Refereed)
Abstract [en]

Diode laser absorption spectroscopy was utilized for non-intrusive assessment of gas content in human body cavities, including intestines and lungs of a new-born, the mastoid bone, and sinus cavities for monitoring sinusitis recovery in adults.

Place, publisher, year, edition, pages
IEEE, 2012
Series
Asia Communications and Photonics Conference and Exhibition, ISSN 2162-108X
National Category
Atom and Molecular Physics and Optics Medical and Health Sciences
Identifiers
urn:nbn:se:kth:diva-318351 (URN)000322085900260 ()2-s2.0-84875145341 (Scopus ID)
Conference
Asia Communications and Photonics Conference (ACP), NOV 07-10, 2012, Guangzhou, PEOPLES R CHINA
Note

Part of proceedings: ISBN 978-1-4673-6274-0

QC 20220922

Available from: 2022-09-22 Created: 2022-09-22 Last updated: 2024-07-12Bibliographically approved
Mei, L., Guan, Z., Somesfalean, G. & Svanberg, S. (2012). Laser-induced fluorescence monitoring of Chinese Longjing tea. In: Remote Sensing For Agriculture, Ecosystems, And Hydrology XIV: . Paper presented at Remote Sensing for Agriculture, Ecosystems, and Hydrology XIV Conference; Edinburgh; United Kingdom; 24 September 2012 through 26 September 2012 (pp. 85311T). SPIE - International Society for Optical Engineering
Open this publication in new window or tab >>Laser-induced fluorescence monitoring of Chinese Longjing tea
2012 (English)In: Remote Sensing For Agriculture, Ecosystems, And Hydrology XIV, SPIE - International Society for Optical Engineering, 2012, p. 85311T-Conference paper, Published paper (Refereed)
Abstract [en]

Laser-induced fluorescence (LIF) spectra of a bush and numerous branches of Chinese Longjing tea were investigated remotely with lidar techniques. The intensity ratio between the far red fluorescence (FRF) and red fluorescence (RF) due to the chlorophyll content of the tea branches were analyzed to study the growth conditions in different villages around Hangzhou, China. Dried Longjing tea leaves were also measured by LIF techniques in the laboratory. A chemometric method based on singular value decomposition (SVD) and linear discriminant analysis (LDA) was used to evaluate the tea qualities of the dried tea leaves.

Place, publisher, year, edition, pages
SPIE - International Society for Optical Engineering, 2012
Series
Proceedings of SPIE - The International Society for Optical Engineering, ISSN 0277-786X ; 8531
Keywords
Laser-induced fluorescence, LIF, chlorophyll, chemometric, FRF, RF
National Category
Engineering and Technology
Identifiers
urn:nbn:se:kth:diva-128962 (URN)10.1117/12.974562 (DOI)000313661400052 ()2-s2.0-84878287383 (Scopus ID)978-0-8194-9271-5 (ISBN)
Conference
Remote Sensing for Agriculture, Ecosystems, and Hydrology XIV Conference; Edinburgh; United Kingdom; 24 September 2012 through 26 September 2012
Note

QC 20130919

Available from: 2013-09-19 Created: 2013-09-17 Last updated: 2024-03-15Bibliographically approved
Mei, L., Larsson, J., Svanberg, S. & Somesfalean, G. (2012). Optical porosimetry in wood using oxygen absorption spectroscopy and frequency domain photon migration. In: Asia Communications and Photonics Conference, ACP: . Paper presented at 2012 Asia Communications and Photonics Conference, ACP 2012, 7 November 2012 through 10 November 2012, Guangzhou (pp. AS1E.5).
Open this publication in new window or tab >>Optical porosimetry in wood using oxygen absorption spectroscopy and frequency domain photon migration
2012 (English)In: Asia Communications and Photonics Conference, ACP, 2012, p. AS1E.5-Conference paper, Published paper (Refereed)
Abstract [en]

A method to assess the relative optical porosity in wood by a combination of gas in scattering media absorption spectroscopy (GASMAS) and frequency domain photon migration (FDPM) is presented. Samples of balsa and pine wood are studied.

Series
Asia Communications and Photonics Conference, ACP, ISSN 2162-108X
Keywords
Frequency domain photon migration, Oxygen absorption, Pine woods, Porosimetry, Scattering media, Frequency domain analysis, Photons, Photonics
National Category
Engineering and Technology
Identifiers
urn:nbn:se:kth:diva-121255 (URN)10.1364/acpc.2012.as1e.5 (DOI)2-s2.0-84875156317 (Scopus ID)
Conference
2012 Asia Communications and Photonics Conference, ACP 2012, 7 November 2012 through 10 November 2012, Guangzhou
Note

QC 20130424

Available from: 2013-04-24 Created: 2013-04-24 Last updated: 2024-07-12Bibliographically approved
Organisations

Search in DiVA

Show all publications