Electrical Power Conditioning System for Thermoelectric Waste Heat Recovery in Commercial Vehicles
KTH, School of Electrical Engineering and Computer Science (EECS), Electrical Engineering, Electric Power and Energy Systems.ORCID iD: 0000-0003-0933-6945
KTH, School of Electrical Engineering (EES), Electric Power and Energy Systems.ORCID iD: 0000-0002-1755-1365
Condensed Matter and Electronics at Universite Paris Diderot.
2018 (English)In: IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, ISSN 2332-7782, no 99Article in journal (Refereed) Published
Abstract [en]

A considerable part of the fuel energy in vehicles never reaches the wheels and entirely converts to waste heat. In a heavy duty vehicle (HDV) the heat power that escapes from the exhaust system may reach 170 kW. The waste heat can be converted into useful electrical power using thermoelectric generator (TEG). During the last decades, many studies on the electrical power conditioning system of TEGs have been conducted. However, there is a lack of studies evaluating the electrical instrumentation, the impact of the converter-efficiency, and the TEG arrangement on a real large-scale TEG on-boarda drivable vehicle. In this study, the most important parameters for designing electrical power conditioning systems for two TEGs, developed for a real-scale HDV as well as experimental results demonstrating the recovered electrical power, are presented. Eight synchronous inter-leaved step-down converters with 98 % efficiency with perturb and observe maximum power point tracker was developed and tested for this purpose. The power conditioning system was communicating with the on-board computers through the controller area network and reported the status of the TEGs and the recovered electrical power. The maximum recovered electrical power from the TEGs reached 1 kW which was transmitted to the electrical system of the vehicle, relieving the internal combustion engine.

Place, publisher, year, edition, pages
IEEE, 2018. no 99
Keywords [en]
Thermoelectricity, power converter, power management, silicon carbide MOSFET, maximum power point tracker, inter-leaved converter, internal combustion engine, energy harvesting, heavy duty vehicle, thermoelectric generator, renewable energy sources, exhaust system
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Research subject
Electrical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-222266DOI: 10.1109/TTE.2018.2796031ISI: 000434447400019Scopus ID: 2-s2.0-85048237914OAI: oai:DiVA.org:kth-222266DiVA, id: diva2:1180153
Note

QC 20180206

Available from: 2018-02-05 Created: 2018-02-05 Last updated: 2022-06-26Bibliographically approved
In thesis
1. Waste-heat Recovery Using Thermoelectricity and Silicon Carbide Power Electronics
Open this publication in new window or tab >>Waste-heat Recovery Using Thermoelectricity and Silicon Carbide Power Electronics
2019 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Energy consumption in the world has increased continuously due to a growing population and increased energy consumption per capita. Moreover, the largest part of consumed energy still comes from fossil sources which in 2016 was more than 130 PWh. In order to minimize the greenhouse effect and meet the climate targets, the world's energy consumption must be greatly reduced and the energy also has to be used more efficiently. Due to the low efficiency of internal combustion engines in vehicles, the transport sector is the second largest source of greenhouse gas emissions, responsible for 20 % of the total CO2 emissions in the EU. In this work the electrical arrangement and power conditioning system suitable for waste heat recovery, using thermoelectric energy conversion in heavy duty vehicles, are investigated. Without a proper power conditioning system, the recovered power from a thermoelectric generator (TEG) disappears in form of Joule-losses. High-efficiency inter-leaved step-down converter with 98 % efficiency was developed and tested on a real-scale prototype truck, equipped with two TEGs. In addition, a strategy was required for the connection of thermoelectric modules (TEM) in the TEGs. A TEG may consist of several hundred TEMs and without a suitable connection, the thermal losses can be so high that the net power, recovered by the TEG is insignificant. In the worst case this can lead to an even higher fuel consumption. Moreover, the possibility to employ silicon carbide (SiC) metal oxide semiconductor field-effect transistor (MOSFET), which is a voltage-controlled and normally-OFF device, with high electric field strength, in such a low-voltage application (100-200 V), was investigated. Due to the high blocking voltage and power density, SiC MOSFETs are expected to replace silicon (Si) insulated gate bipolar transistors (IGBTs) in power converters. However, in low-voltage applications where Si MOSFETs are usually used, there have not been any obvious advantages to use SiC MOSFETs as a substitute for Si MOSFETs. Here, it is shown that SiC MOSFETs can advantageously be used in low-voltage applications. SiC MOSFETs have exceptional properties that nevertheless are fully utilized today. The packages of currently available SiC devices are the same as those previously used for Si devices, with moderate electrical and thermal characteristics. This results in slow switching speed, unnecessary losses. A half-bridge planar module using SiC MOSFET bare dies were designed, manufactured and tested. It was shown that a module with the same structure and 8 SiC MOSFETs can be manufactured with ultra-low parasitic inductances. The total switching energy was found to be 4.4 mJ which is approx. 63 % lower than commercially available modules.This thesis can be divided into three parts. In the first part, thermoelectricity is introduced and an introduction of SiC MOSFETs and its applications are given. In the second part, the results of waste heat recovery using TEG and its electrical arrangement in a Scania truck are presented. In this part, also the output power and the efficiency of the converter, using Si and SiC MOSFETs, are discussed. In the final part, the proposed planar power module with SiC MOSFET bare dies, its benefits such as reduced switching losses and double-sided cooling, are presented.

Abstract [sv]

I denna avhandling behandlas ämnet termoelektrisk energiomvandling från spillvärmen i avgassystemet i tunga fordon, med särskild fokus på el-komponenter och effektomvandlare som passar bäst till sådana applikationer. Utan en passande omvandlartopologi som kontrollerar och justerar effekten, skulle en stor del av den utvunna effekten från en termoelektrisk generator (TEG) försvinna i form av värme-förluster. Högverkningsgradig inter-leaved step-down effektomvandlare med 98 % verkningsgrad utvecklades och testades på en prototyplastbil. Vidare behövde en strategi tas fram för koppling av termoelektriska moduler (TEM) i TEG:en. En TEG kan bestå av flera hundra TEM:ar och utan korrekt koppling, kan de termiska förlusterna bli så stora att uteffekten från en TEG kan bli obetydlig och i värsta fall även leda till högre bränsleförbrukning. I avhandlingen har även möjligheterna till att använda kiselkarbid (SiC) metal-oxide semiconductor field-effect transistor (MOSFET) som är spänningsstyrd och normally-OFF, med hög elektrisk fältstyrka (1.2-1.7 kV)  i en sådan lågspänningsapplikation (100-200 V), undersöktes. På grund av den höga blockeringsspänningen och effektdensiteten, antas SiC MOSFET:ar ersätta kisel (Si) insulated-gate bipolar transistorer (IGBT:er) i effektomvandlare. I lågspänningsapplikationer används Si MOSFET:ar ofta, och det har inte funnits några självklara fördelar med att ersätta de lågspända Si MOSFET:arna med högspända SiC MOSFET:ar. Här visas det att det finns fördelar med att använda SiC MOSFET:ar även för lägre spänningar. SiC MOSFET:ar har exceptionella egenskaper som dock inte kan utnyttjas fullständigt idag eftersom det fortfarande används äldre, icke-anpassade kåpor som är lämpade för Si komponenter. En halvbrygga med 4st. SiC MOSFET bare dies blev designad, tillverkad och testad. Den föreslagna modulen klarar av 1.2 kV & 400 A med Eon och Eoff på 4.4 mJ vilket är ca. 63 % lägre än kommersiellt tillgängliga moduler. Avhandlingen kan delas i tre delar. I första delen introduceras termoelektricitet. I andra delen redovisas resultaten från återvinning av spillvärmen, med hjälp av TEG och dess elektriska anordning i en Scania lastbil. Här presenteras även omvandlarens verkningsgrad med Si- eller SiC MOSFET:ar som switch. Slutligen presenteras användningen av SiC MOSFET:ar, dess fördelar samt förslag på förbättring för att minska switchförlusterna.

Place, publisher, year, edition, pages
KTH Royal Institute of Technology, 2019. p. 110
Series
TRITA-EECS-AVL ; 2019:24
Keywords
Thermoelectricity, Power converter, Silicon Carbide, MOSFET, Power management, Thermoelectric generator, Renewable energy, Vehicle, Power electronic, Waste heat, Ultra-low inductance, Power module, Termoelektrisk energiomvandling, Kiselkarbid MOSFET, Effektomvandlare, Förnybar energikälla, Effektelektronik, Spillvärme, Effektmodul, Låg induktiv module
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Research subject
Electrical Engineering
Identifiers
urn:nbn:se:kth:diva-246206 (URN)978-91-7873-137-4 (ISBN)
Public defence
2019-04-08, Kollegiesalen, KTH-huset, Brinellvägen 8, Stockholm, 10:00 (English)
Opponent
Supervisors
Note

QC 20190318

Available from: 2019-03-18 Created: 2019-03-16 Last updated: 2022-06-26Bibliographically approved

Open Access in DiVA

fulltext(2009 kB)892 downloads
File information
File name FULLTEXT02.pdfFile size 2009 kBChecksum SHA-512
3c2332b6ea872f1324f4545ed7378b69080a81031629015522fc1cae86d46ec651bafc8de7668d6932df586069d16311ff46bf3b2158ece7655b37aa9a0e37e1
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopusIEEE Early Access Articles

Authority records

Risseh, ArashNee, Hans-Peter

Search in DiVA

By author/editor
Risseh, ArashNee, Hans-Peter
By organisation
Electric Power and Energy SystemsElectric Power and Energy Systems
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 894 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 676 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf