kth.sePublications KTH
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Continuous versus pulsating flow boiling. Experimental comparison, visualization, and statistical analysis
Tech Univ Denmark, Dept Mech Engn, Nils Koppels Alle,Bygn 403, DK-2800 Lyngby, Denmark..
Tech Univ Denmark, Dept Mech Engn, Nils Koppels Alle,Bygn 403, DK-2800 Lyngby, Denmark..ORCID iD: 0000-0002-0503-6286
Tech Univ Denmark, Dept Mech Engn, Nils Koppels Alle,Bygn 403, DK-2800 Lyngby, Denmark..ORCID iD: 0000-0003-2179-0235
KTH, School of Industrial Engineering and Management (ITM), Energy Technology.ORCID iD: 0000-0002-9902-2087
Show others and affiliations
2017 (English)In: Science and Technology for the Built Environment, ISSN 2374-4731, E-ISSN 2374-474X, Vol. 23, no 6, p. 983-996Article in journal (Refereed) Published
Abstract [en]

This experimental study investigates an active method for flow boiling heat transfer enhancement by means of fluid flow pulsation. The hypothesis is that pulsations increase the flow boiling heat transfer by means of better bulk fluid mixing, increased wall wetting, and flow-regime destabilization. The fluid pulsations are introduced by a flow modulating expansion device and are compared with continuous flow by a stepper-motor expansion valve in terms of time-averaged heat transfer coefficient. The cycle time ranges from 1 to 9 s for the pulsations. The time-averaged heat transfer coefficients are reduced from transient measurements immediately downstream of the expansion valves at low vapor qualities. The results show that the pulsations improve the time-averaged heat transfer coefficient by 3.2% on average at low cycle time (1 to 2 s), whereas the pulsations may reduce the time-averaged heat transfer coefficient by as much as 8% at high heat flux (q >= 35 kW/m(2)) and cycle time (8 s). The latter reduction is attributed to a significant dry-out that occurs when the flow modulating expansion valve is closed. Additionally, the effect of fluid flow pulsations is found to be statistically significant, disregarding the lowest heat flux measurements.

Place, publisher, year, edition, pages
Taylor & Francis, 2017. Vol. 23, no 6, p. 983-996
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:kth:diva-243539DOI: 10.1080/23744731.2017.1319667ISI: 000407520300011Scopus ID: 2-s2.0-85019737561OAI: oai:DiVA.org:kth-243539DiVA, id: diva2:1286778
Note

QC 20190207

Available from: 2019-02-07 Created: 2019-02-07 Last updated: 2022-06-26Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Palm, Björn

Search in DiVA

By author/editor
Elmegaard, BrianMeyer, Knud ErikPalm, Björn
By organisation
Energy Technology
In the same journal
Science and Technology for the Built Environment
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 82 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf