Textile-Friendly Interconnection between Wearable Measurement Instrumentation and Sensorized Garments-Initial Performance Evaluation for Electrocardiogram Recordings
Univ Boras, Swedish Sch Text, S-50190 Boras, Sweden.;Karolinska Univ Hosp, Dept Med Care Technol, S-14157 Huddinge, Sweden.;Karolinska Inst, Inst Clin Sci Intervent & Technol, S-14157 Huddinge, Sweden..
Univ Boras, Swedish Sch Text, S-50190 Boras, Sweden..ORCID iD: 0000-0003-1044-5129
Chalmers Univ Technol, Dept Elect Engn, S-41296 Gothenburg, Sweden..ORCID iD: 0000-0002-3256-9029
RISE Res Inst Sweden, Box 857, S-50115 Boras, Sweden..
Show others and affiliations
2019 (English)In: Sensors, E-ISSN 1424-8220, Vol. 19, no 20, article id 4426Article in journal (Refereed) Published
Abstract [en]

The interconnection between hard electronics and soft textiles remains a noteworthy challenge in regard to the mass production of textile-electronic integrated products such as sensorized garments. The current solutions for this challenge usually have problems with size, flexibility, cost, or complexity of assembly. In this paper, we present a solution with a stretchable and conductive carbon nanotube (CNT)-based paste for screen printing on a textile substrate to produce interconnectors between electronic instrumentation and a sensorized garment. The prototype connectors were evaluated via electrocardiogram (ECG) recordings using a sensorized textile with integrated textile electrodes. The ECG recordings obtained using the connectors were evaluated for signal quality and heart rate detection performance in comparison to ECG recordings obtained with standard pre-gelled Ag/AgCl electrodes and direct cable connection to the ECG amplifier. The results suggest that the ECG recordings obtained with the CNT paste connector are of equivalent quality to those recorded using a silver paste connector or a direct cable and are suitable for the purpose of heart rate detection.

Place, publisher, year, edition, pages
MDPI , 2019. Vol. 19, no 20, article id 4426
Keywords [en]
conductive polymers, wearable technology, smart textiles, textile-electronic integration
National Category
Medical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-265489DOI: 10.3390/s19204426ISI: 000497864700074PubMedID: 31614859Scopus ID: 2-s2.0-85073476096OAI: oai:DiVA.org:kth-265489DiVA, id: diva2:1378605
Note

QC 20191213

Available from: 2019-12-13 Created: 2019-12-13 Last updated: 2024-03-15Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Lu, KeAbtahi, Farhad

Search in DiVA

By author/editor
Soroudi, AzadehLu, KeAbtahi, FarhadSkrifvars, Mikael
By organisation
Ergonomics
In the same journal
Sensors
Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 136 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf