Minimizing the airborne particle migration to the operating room during door opening
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Sustainable Buildings.ORCID iD: 0000-0002-9361-1796
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Sustainable Buildings.ORCID iD: 0000-0001-7032-3049
Show others and affiliations
2019 (English)In: Proceedings 10th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings, IAQVEC, Institute of Physics Publishing , 2019, no 3Conference paper, Published paper (Refereed)
Abstract [en]

Airborne bacteria that enter an open wound during surgery can result in post-operative infections, commonly referred to as surgical site infections (SSIs). The level of contaminants is usually lower in the operating rooms (ORs) in contrast to adjacent corridors. Penetration of particles carrying bacteria through the doorway during a door opening gives rise to the OR contaminant level as door-opening and passage may occur every 2.5 minutes during a given surgical activity. The authors had previously conducted a successful research study to reduce the contaminant migration from an anteroom, through the doorway, into an Airborne Infection Isolation Room (AIIR). In contrast to the AIIRs, the ORs are usually over-pressured related to the surrounding environments. However, both ORs and AIIRs share the same interest in avoiding air exchange between the room and the adjacent space. This paper, built upon the previous research achievement, proposes an innovative design solution to reduce the bacteria penetration to the ORs during a door opening and staff passage. Previously achieved results from CFD simulation and laboratory measurement confirmed that installing a ventilation unit that supplies a high air volume into the OR through low-velocity wall diffusers, may significantly reduce the contaminant migration to the OR during door-opening activities.

Place, publisher, year, edition, pages
Institute of Physics Publishing , 2019. no 3
Keywords [en]
Air, Air quality, Bacteria, Contamination, Energy conservation, Historic preservation, Indoor air pollution, Operating rooms, Transplantation (surgical), Ventilation, Airborne bacteria, Airborne infection, Contaminant migration, Innovative design, Laboratory measurements, Research achievements, Surgical site infections, Surrounding environment, Doors
National Category
Building Technologies
Identifiers
URN: urn:nbn:se:kth:diva-268032DOI: 10.1088/1757-899X/609/3/032055Scopus ID: 2-s2.0-85074422145OAI: oai:DiVA.org:kth-268032DiVA, id: diva2:1416171
Conference
10th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings, IAQVEC 2019, 5-7 September 2019
Note

QC 20200322

Available from: 2020-03-22 Created: 2020-03-22 Last updated: 2023-03-08Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Sadrizadeh, SasanSadeghian, ParastooWang, Cong

Search in DiVA

By author/editor
Sadrizadeh, SasanSadeghian, ParastooWang, Cong
By organisation
Sustainable Buildings
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 178 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf