kth.sePublications KTH
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Impact of door opening on the risk of surgical site infections in an operating room with mixing ventilation
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Sustainable Buildings.ORCID iD: 0000-0003-0550-1149
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering.ORCID iD: 0000-0003-1882-3833
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Sustainable Buildings.ORCID iD: 0000-0002-9361-1796
2019 (English)In: Indoor + Built Environment, ISSN 1420-326X, E-ISSN 1423-0070Article in journal (Refereed) Published
Abstract [en]

Operating rooms (ORs) often have door openings connected to uncontrolled areas that are more contaminated. Opening the door may allow an inflow of contaminated air, degrade the microbiological air cleanliness and possibly cause surgical site infections (SSIs). This study numerically investigated the transient airflow and bacteria-carrying particles spread caused by the opening of a sliding door in an OR with mixing ventilation. Results showed that a single door opening raises the overall OR contamination by 2.1 colony-forming units per cubic metre (CFU/m3) under a temperature difference of about 3°C. With a similar level of overall contamination, the risk of infections differs dramatically, as the corresponding contamination at the surgical site ranges from lower than 1 CFU/m3 to higher than 10 CFU/m3. This implies that quantifying only the air volume exchange is not sufficient for a valid and reliable assessment of the impact of door openings on the risk of SSIs. Temporarily reducing the OR exhaust flow during door operation was found to be an effective solution to minimize the impact of door openings on the risk of infections. In the case examined in the present study, a 20–30% reduction in OR exhaust flow decreases the airborne contamination to a sufficiently low level.

Place, publisher, year, edition, pages
SAGE Publications Ltd , 2019.
Keywords [en]
Bacteria-carrying particles, CFD, Door opening, Operating room, Surgical site infections
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:kth:diva-268593DOI: 10.1177/1420326X19888276ISI: 000498342100001Scopus ID: 2-s2.0-85075371015OAI: oai:DiVA.org:kth-268593DiVA, id: diva2:1428605
Note

QC 20200506

Available from: 2020-05-06 Created: 2020-05-06 Last updated: 2023-03-08Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Wang, CongHolmberg, StureSadrizadeh, Sasan

Search in DiVA

By author/editor
Wang, CongHolmberg, StureSadrizadeh, Sasan
By organisation
Sustainable BuildingsCivil and Architectural Engineering
In the same journal
Indoor + Built Environment
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 456 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf