kth.sePublications KTH
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Laboratory water-window x-ray microscopy
KTH, School of Engineering Sciences (SCI), Applied Physics, Biomedical and X-ray Physics.ORCID iD: 0000-0002-3717-7307
Tech Univ Berlin, Inst Opt & Atom Phys, Hardenbergstr 36, D-10623 Berlin, Germany.;Berlin Lab Innovat Xray Technol BLiX, Hardenbergstr 36, D-10623 Berlin, Germany..
Tech Univ Berlin, Inst Opt & Atom Phys, Hardenbergstr 36, D-10623 Berlin, Germany.;Berlin Lab Innovat Xray Technol BLiX, Hardenbergstr 36, D-10623 Berlin, Germany..
KTH, School of Engineering Sciences (SCI), Applied Physics, Biomedical and X-ray Physics.ORCID iD: 0000-0002-4394-0591
Show others and affiliations
2020 (English)In: Optica, E-ISSN 2334-2536, Vol. 7, no 6, p. 658-674Article, review/survey (Refereed) Published
Abstract [en]

Soft x-ray microscopy in the water window (similar to 285-535 eV) is an emerging and unique tool for 2D and 3D imaging of unstained intact cellular samples in their near-native state with few-10-nm detail. However, present microscopes rely on the high x-ray brightness of synchrotron-radiation sources. Having access to water-window microscopy in the home laboratory would increase the impact and extend the applicability of the method. In the present paper, we review three decades of efforts to build laboratory water-window microscopes and conclude that the method is now reaching the maturity to allow biological studies. The instruments as well as their key components are quantitatively and qualitatively compared. We find that the brightness and the reliability of the laboratory source are the most critical parameters, but that the optics as well as the sample preparation also must be optimized to enable high-resolution imaging with adequate exposure times. We then describe the two sister microscopes in Stockholm and Berlin, which allow reliable high-resolution biological imaging with short exposure times of a few tens of seconds in 2D and a few tens of minutes in 3D. They both rely on a liquid-jet laser-plasma source combined with high-reflectivity normal-incidence multilayer condenser optics, high-resolution zone-plate imaging optics, CCD detection, and cryogenic sample handling. Finally, we present several examples of biological imaging demonstrating the unique properties of these instruments. 

Place, publisher, year, edition, pages
The Optical Society , 2020. Vol. 7, no 6, p. 658-674
National Category
Atom and Molecular Physics and Optics
Identifiers
URN: urn:nbn:se:kth:diva-278940DOI: 10.1364/OPTICA.393014ISI: 000550698300015Scopus ID: 2-s2.0-85086837390OAI: oai:DiVA.org:kth-278940DiVA, id: diva2:1461397
Note

QC 20200826

Available from: 2020-08-26 Created: 2020-08-26 Last updated: 2024-03-15Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Kördel, MikaelVogt, UlrichFogelqvist, EmelieSellberg, Jonas A.Hertz, Hans M.

Search in DiVA

By author/editor
Kördel, MikaelVogt, UlrichFogelqvist, EmelieSellberg, Jonas A.Hertz, Hans M.
By organisation
Biomedical and X-ray Physics
In the same journal
Optica
Atom and Molecular Physics and Optics

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 246 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf