Cooling capacity of diffuse ceiling ventilation system and the impact of heat load and diffuse panel distribution
(Aalborg University)
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Sustainable Buildings.ORCID iD: 0000-0001-7032-3049
(Aalborg University)
(Aalborg University)
Show others and affiliations
2020 (English)In: Building and Environment, ISSN 0360-1323, E-ISSN 1873-684X, Vol. 185, article id 107290Article in journal, Editorial material (Refereed) Published
Abstract [en]

Diffuse ceiling ventilation system is an air distribution system based on the low-impulse supply of air through the perforated panels installed as the suspended ceiling. A ceiling with diffuse supply typically consists of active and passive panels, where active panels allow airflow. Diffuse ceiling ventilation system has been proven to have a higher cooling capacity compared to conventional air distribution systems, e.g. mixing or displacement ventilation systems. Several parameters have an impact on the cooling capacity of the system though. The present research study evaluates the cooling capacity of the diffuse ceiling ventilation system in connection to two essential parameters, i.e. the distribution of heat load in the room and the distribution of active diffuse panels in the ceiling. The evaluation is based on full-scale experiments performed in a laboratory-controlled environment as well as numerical studies with Computational Fluid Dynamics (CFD) simulations. The cooling capacity of the system in several scenarios with different heat load and active diffuse panel distribution are compared under a certain thermal comfort condition. The results indicate the highest cooling capacity in the scenario with evenly distributed heat load in the room and compact distribution of active diffuse panels in the ceiling, while the active panels cover almost one-third of the suspended ceiling. The system is at its minimum cooling capacity in the scenario with compact heat load distribution in the room and disperse distribution of active diffuse panels in the ceiling.

Place, publisher, year, edition, pages
Elsevier, 2020. Vol. 185, article id 107290
Keywords [en]
Diffuse ceiling ventilation, Cooling capacity, CFD simulation, Parametric study
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:kth:diva-284798DOI: 10.1016/j.buildenv.2020.107290ISI: 000579911400038Scopus ID: 2-s2.0-85091339145OAI: oai:DiVA.org:kth-284798DiVA, id: diva2:1492897
Note

QC 20201118

Available from: 2020-11-03 Created: 2020-11-03 Last updated: 2022-06-25Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Sadeghian, ParastooSadrizadeh, Sasan

Search in DiVA

By author/editor
Sadeghian, ParastooSadrizadeh, Sasan
By organisation
Sustainable Buildings
In the same journal
Building and Environment
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 176 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf