kth.sePublications KTH
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Heating energy implications of utilizing gas-phase air cleaners in buildings?: centralized air handling units
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Building Technology and Design.ORCID iD: 0000-0002-5938-4614
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering.ORCID iD: 0000-0003-1882-3833
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Chemical Engineering, Process Technology.ORCID iD: 0000-0001-5886-415X
Aalborg Univ, Dept Built Environm, Copenhagen, Denmark..
Show others and affiliations
2022 (English)In: Results in Engineering (RINENG), ISSN 2590-1230, Vol. 16, article id 100619Article in journal (Refereed) Published
Abstract [en]

Ventilation systems are a vital component of buildings in order to ensure a healthy and comfortable environment for the occupants. In cold climate regions, ventilation systems are responsible for approximately 30% of building heat losses. In addition to outdoor pollutants (particulate matters, NOX, etc.), indoor emissions from materials in the form of gas pollutants and emissions from occupants are the principal indoor air quality metrics for securing an acceptable indoor concentration level. Therefore, it is of great interest to study the use of gas-phase air cleaning technologies in low-energy centralized air handling units. This study focused on reducing buildings' heating requirements by recirculating indoor air while maintaining an acceptable indoor air quality level. The heating performance of a typical residential and office building in the central Swedish climate was studied by dynamic building simulations. Indoor air recirculation rates and air changes per hour were the key parameters considered during the simulation of the building's heating demand and indoor gaseous air pollution concen-tration. We found that introducing indoor air recirculation reduces buildings' heating demand depending on the air change rates per hour. The results show that it is possible to reduce the energy use for heating by less than approximaytely 10% and 20% for residential and office buildings, respectively and maintain acceptable indoor air quality by using gas-phase air cleaning.

Place, publisher, year, edition, pages
Elsevier BV , 2022. Vol. 16, article id 100619
Keywords [en]
Indoor air quality, Gas filter, Air cleaner, Volatile organic compounds, Energy use
National Category
Building Technologies
Identifiers
URN: urn:nbn:se:kth:diva-322171DOI: 10.1016/j.rineng.2022.100619ISI: 000880671100005Scopus ID: 2-s2.0-85140808375OAI: oai:DiVA.org:kth-322171DiVA, id: diva2:1716018
Note

QC 20221205

Available from: 2022-12-05 Created: 2022-12-05 Last updated: 2023-06-08Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Nourozi, BehrouzHolmberg, StureDuwig, ChristopheSadrizadeh, Sasan

Search in DiVA

By author/editor
Nourozi, BehrouzHolmberg, StureDuwig, ChristopheWargocki, PawelSadrizadeh, Sasan
By organisation
Building Technology and DesignCivil and Architectural EngineeringProcess Technology
In the same journal
Results in Engineering (RINENG)
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 190 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf