Effect of low rate ratio and positioning on a lighthouse tip ECMO return cannula
KTH, School of Engineering Sciences (SCI), Engineering Mechanics. KTH, School of Engineering Sciences (SCI), Centres, Linné Flow Center, FLOW.ORCID iD: 0000-0003-0716-465x
KTH, School of Engineering Sciences (SCI), Engineering Mechanics. KTH, School of Engineering Sciences (SCI), Centres, Linné Flow Center, FLOW.ORCID iD: 0000-0003-0699-3325
Dept. Physiology and Pharmacology, Karolinska Institutet, Solna.ORCID iD: 0000-0003-4124-4581
KTH, School of Engineering Sciences (SCI), Engineering Mechanics. KTH, School of Engineering Sciences (SCI), Centres, Linné Flow Center, FLOW.ORCID iD: 0000-0001-9976-8316
2023 (English)In: Biomechanics and Modeling in Mechanobiology, ISSN 1617-7959, E-ISSN 1617-7940, Vol. 22, no 6, p. 1891-1899Article in journal (Other academic) Published
Abstract [en]

Extracorporeal membrane oxygenation is a life-saving support therapy in the case of cardiopulmonary refractory failure. Its use is associated to complications due to the presence of artificial surfaces and supraphysiological stress conditions. Thus, knowledge of the fluid structures associated to each component can give insight into sources of blood damage. In this study, an experimentally validated numerical study of a conventional lighthouse tip cannula in return configuration was carried out to characterize the flow structures using water or a Newtonian blood analog with different flow rate ratios and cannula positioning and their influence on hemolysis. The results showed that strong shear layers developed where the jets from the side holes met the co-flow. Stationary backflow regions at the vessel wall were also present downstream of the cannula. In the tilted case, the recirculation was much more pronounced on the wide side and almost absent on the narrow side. Small vortical backflow structures developed at the side holes which behaved like obstacles to the co-flow, creating pairs of counter-rotating vortices, which induced locally higher risk of hemolysis. However, global hemolysis index did not show significant deviations. Across the examined flow rate ratios, the holes on the narrow side consistently reinfused a larger fraction of fluid. A radial force developed in the tilted case in a direction so as to recenter the cannula in the vessel.

Place, publisher, year, edition, pages
Springer Nature , 2023. Vol. 22, no 6, p. 1891-1899
Keywords [en]
ECMO, CFD, return cannula, hemolysis, PIV, recirculation, POD
National Category
Fluid Mechanics
Research subject
Engineering Mechanics
Identifiers
URN: urn:nbn:se:kth:diva-326204DOI: 10.1007/s10237-023-01741-2ISI: 001029357800001PubMedID: 37454305Scopus ID: 2-s2.0-85164906954OAI: oai:DiVA.org:kth-326204DiVA, id: diva2:1753286
Funder
EU, European Research Council, 101045453
Note

QC 20230427

Available from: 2023-04-26 Created: 2023-04-26 Last updated: 2025-03-27Bibliographically approved
In thesis
1. Computational modelling of blood flow in medical assist devices
Open this publication in new window or tab >>Computational modelling of blood flow in medical assist devices
2023 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Extracorporeal membrane oxygenation (ECMO) is a life-saving support treat-ment in case of pulmonary and/or cardiac failure. An artificial extracorporealcircuit is used to offload the function of lungs and/or heart. Patient blood is drained through a drainage cannula, pumped with a centrifugal pump, oxygenated in a membrane lung and returned to the body through a reinfusion cannula. Tubing and connectors complete the circuit. However, its use canlead to thromboembolic and haemolytic complications, which are related to mechanical stresses arising in the flow of blood through its components. Numerical simulations of some of the pumps and cannulae used in the circuit were performed to investigate the flow structures developing in these components and their relation to measures of blood damage in the form of platelet activation state (PAS) and haemolysis index (HI). Simulations of two magnetically levitated centrifugal ECMO pumps were performed both in on- and off-label conditions with flow rates compatible with adult and neonatal use. The results showed that off-label low flow rate can be damaging due to an increase of residence time of the particles, which exposed them for longer to non-physiological stress. This held true for both passive tracers and inertial particles subjected to lift and drag. The neonatal pump showed a backflow structure with flow swirling back to the inlet tubing over its whole labelled range. Simulations of a lighthouse drainage cannula were undertaken to assess drainage characteristics at different haematocrits and flow rate ratios. The results indicated that the flow field was dominated by a jet in crossflow type of structure, with the most proximal holes draining the largest amount of fluid in all the studied cases and for all the considered haematocrits. The effects due to non-Newtonian behaviour of blood were less relevant in the drainage area, allowing to use a Reynolds number analogy to bridge between water and blood results.A lighthouse cannula in return configuration was also considered in both a centred and a tilted position. A characteristic confined jet configuration was found, with a backflow developing at the vessel wall, increasing residence time. In the tilted case, a group of small vortical structures developed at the holes close to the wall, which behaved as an obstacle to the vessel flow and increased both residence time and stress. This led to locally increased haemolysis which, however, did not impact haemolysis at large due to the low flow exposed to this area. The use of different viscosity models in this case led to small variations in the results, which were minor compared to the uncertainty introduced by the use of different model coefficients in the computation of the haemolysis index.

Abstract [sv]

Extrakorporeal membranoxygenering (ECMO) är en livräddande stödbehandling vid lung- och/eller hjärtsvikt. En artificiell extrakorporeal krets används för att stödja hjärt-lungfunktion. Patientblod dräneras via en dräneringskanyl, pumpas med en centrifugalpump genom membranlunga (gasväxlare) för syresättning och koldioxidclearance, för att sedan återföras till patienten via en returkanyl. Slangar och konnektorer sammankopplar kretsen. Användning av ECMO kan leda till tromboemboliska och hemolytiska komplikationer relaterade till mekaniska skjuvkrafter som uppstår när blodet strömmar genom ECMO-systemetskomponenter. Numeriska simuleringar av några av de pumpar och kanyler som används vid ECMO utfördes för att undersöka flödesstrukturer som skapas i systemkomponenter och deras relation till blodtrauma skattat som Plateletactivation state (PAS) och Haemolysis index (HI). Simuleringar av två centrifugalpumpar utfördes både inom och utanför rekommenderade flödesvolymer kompatibla med vuxen och neonatal ECMO användning. Resultaten visade att låg flödeshastighet off-design kan vara skadlig på grund av en ökad uppehållstid (residence time) för partiklarna i undersökt område. Detta gällde både passiva och tröghetsberoende partiklar som utsätts för lift och drag. Neonatalpumpen visade en motströms flödesstruktur i form av virvel utefter pumpinloppets väg över hela rekommenderade flödesområdet. Simulering av en dränkanyl med sidohål genomfördes för att bedöma dränegenskaper vid olika hematokritvärden och flödeshastigheter. Resultaten indikerade att flödesmönster dominerades av en struktur “jet in crossflow”. De mest proximala hålen dränerade mest vätska i alla studerade fall inklusive hematokritfraktioner. Effekterna av blodets icke-Newtonska egenskaper var inte avgörande inom testområdet vilket möjliggjorde användande av Reynolds-tal för att koppla vatten och blodresultat. En returkanyl undersöktes både i centrerad och vinklad position i kärlet. En karakteristisk “confined jet”konfiguration sågs, med ett returflöde somutvecklades vid kärlväggen. Detta orsakade ökad residence time. I vinkladposition noterades en grupp små virvelstrukturer vid hålen nära kärlväggen vilka funktionellt betedde sig som hinder för blodflödet i kärlet men skapade också mera shear stress och förlängd residence time. Lokalt ökad hemolys avröda blodkroppar sågs, vilket dock inte var relevant i ett globalt perspektivp å grund av det lågt fraktionellt flödet vid sidohålen. Användningen av olika viskositetsmodeller gav små variationer i resultaten, vilka blev obetydliga med den osäkerhet som introducerades av användningen olika modellkoefficienter vid beräkning av hemolysindex.

Place, publisher, year, edition, pages
Stockholm: KTH, 2023
Series
TRITA-SCI-FOU ; 2023:20
Keywords
computational fluid dynamics, haemodynamics, platelet activation, thrombogenicity, haemolysis, extracorporeal membrane oxygenation, sensitivity
National Category
Fluid Mechanics
Research subject
Engineering Mechanics
Identifiers
urn:nbn:se:kth:diva-326501 (URN)978-91-8040-562-1 (ISBN)
Public defence
2023-05-25, F3, Lindstedtsvägen 26, Stockholm, 10:00 (English)
Opponent
Supervisors
Funder
EU, European Research Council, 101045453Swedish Research Council, 2019-04800
Note

QC 230503

Available from: 2023-05-03 Created: 2023-05-03 Last updated: 2025-02-09Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Fiusco, FrancescoLemétayer, JulienBroman, Lars MikaelPrahl Wittberg, Lisa

Search in DiVA

By author/editor
Fiusco, FrancescoLemétayer, JulienBroman, Lars MikaelPrahl Wittberg, Lisa
By organisation
Engineering MechanicsLinné Flow Center, FLOW
In the same journal
Biomechanics and Modeling in Mechanobiology
Fluid Mechanics

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 623 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf