kth.sePublications KTH
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
CFD simulations of a semi-transverse ventilation system in a long tunnel
Univ Isfahan, Fac Engn, Dept Mech Engn, Esfahan 8174673441, Iran..
Shiraz Univ, Sch Mech Engn, Shiraz 7193616548, Iran..
Shiraz Univ, Sch Mech Engn, Shiraz 7193616548, Iran.;Univ Alberta, Dept Mech Engn, Edmonton, AB T6G 2R3, Canada..
Shiraz Univ, Sch Mech Engn, Shiraz 7193616548, Iran..
Show others and affiliations
2023 (English)In: Underground Space, ISSN 2096-2754, E-ISSN 2467-9674, Vol. 11, p. 153-170Article in journal (Refereed) Published
Abstract [en]

In the present work, a semi-transverse ventilation system in a long tunnel with a length of 4.9 km, as a complex case study, is numerically studied by performing a set of three-dimensional steady incompressible computational fluid dynamics (CFD) simulations. The ventilation system consisted of a ceiling duct connected to two axial fans at the ending portals, and a series of jet fans in the main tunnel for supporting airflow in the desired direction. To focus on what can and cannot be achieved in commissioning tests, the ventilation system's performance in various scenarios is numerically evaluated with two different tunnel states; empty tunnel and complete traffic congestion with 1176 stationary vehicles - which is almost impossible to evaluate during a commissioning test. By considering two hypothetical locations for the extraction zone from the main tunnel (in a distance of 450 and 1000 m from one portal), it is shown that the required number of jet fans in a traffic condition drops from 57 for the first extraction location to 43 (25% decrease) when the ventilation system extracts from the second zone. We show that if only the close axial fan to the extraction zone is activated, the required number of jet fans reduces by 56% and 72% for the first and second extraction locations, respectively. This finding can provide a cheaper and easier controlling scenario for emergency ventilation.

Place, publisher, year, edition, pages
Elsevier BV , 2023. Vol. 11, p. 153-170
Keywords [en]
Keywords, CFD, Semi-transverse ventilation, Tunnel, Ceiling duct, Traffic
National Category
Fluid Mechanics
Identifiers
URN: urn:nbn:se:kth:diva-329897DOI: 10.1016/j.undsp.2022.12.004ISI: 000994774700001Scopus ID: 2-s2.0-85158879142OAI: oai:DiVA.org:kth-329897DiVA, id: diva2:1774470
Note

QC 20230626

Available from: 2023-06-26 Created: 2023-06-26 Last updated: 2025-12-15Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Sadrizadeh, SasanAbouali, Omid

Search in DiVA

By author/editor
Sadrizadeh, SasanAbouali, Omid
By organisation
Civil and Architectural Engineering
In the same journal
Underground Space
Fluid Mechanics

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 185 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf