kth.sePublications KTH
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Simple solutions for improving thermal comfort in huts in the highlands of Peru
KTH, School of Industrial Engineering and Management (ITM), Energy Technology, Applied Thermodynamics and Refrigeration. GRUPO de Apoyo al Sector Rural de la Pontificia Universidad Católica del Perú, GRUPO de Apoyo al Sector Rural de la Pontificia Universidad Católica del Perú.ORCID iD: 0000-0002-5512-1286
KTH, School of Industrial Engineering and Management (ITM), Energy Technology, Applied Thermodynamics and Refrigeration.ORCID iD: 0000-0001-5556-9294
KTH, School of Industrial Engineering and Management (ITM), Energy Technology, Applied Thermodynamics and Refrigeration.ORCID iD: 0000-0002-9902-2087
2023 (English)In: Heliyon, E-ISSN 2405-8440, Vol. 9, no 10, article id e19709Article in journal (Refereed) Published
Abstract [en]

In the Peruvian mountains, hundreds of thousands of rural households living in poverty live in cold indoor environments, close to 0 °C. Indoor cold causes thousands of respiratory diseases and excess of winter deaths. In this study, we numerically calculated the impact of simple low-cost refurbishments on discomfort time during a year. Using EnergyPlus and Python, we modelled a typical one-room hut used as bedroom built with a metal-sheet roof, adobe walls, dirt floors, and high infiltration rates. Then, 9 individual solutions were studied, and their combination resulted in 215 different hut designs. The model was calibrated with field measurements to estimate the infiltration. All the numerical calculations included an uncertainty analysis based on Monte Carlo method, and a sensitivity analysis to assess the impact of reducing infiltration on discomfort time. The base case had a discomfort time of 44% of time. The calibration of infiltration resulted in a mean hourly air exchange rate equal to 29.1 h−1 (SD = 17.0 h−1). Five different designs formed the Pareto front that optimized discomfort time and costs. The solution with the lowest discomfort time during a year, 37% of the time, was adding insulation to the roof (U = 0.83 W/m2•K) and the door (U = 1.00 W/m2•K); and its cost was 286USD. In this solution, when infiltrations were reduced to 4.1 h−1 (SD = 4.1 h−1) discomfort time decreased until 16%. These results benefit those households that nowadays invest their limited resources to improve their living conditions but without technical guidance.

Place, publisher, year, edition, pages
Elsevier BV , 2023. Vol. 9, no 10, article id e19709
Keywords [en]
Andes, Building performance simulation, Low indoor temperatures, Low-cost refurbishments, Uncertainty analysis
National Category
Building Technologies
Identifiers
URN: urn:nbn:se:kth:diva-337426DOI: 10.1016/j.heliyon.2023.e19709ISI: 001156762900001Scopus ID: 2-s2.0-85171746122OAI: oai:DiVA.org:kth-337426DiVA, id: diva2:1801950
Note

QC 20231003

Available from: 2023-10-03 Created: 2023-10-03 Last updated: 2024-02-26Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Mejia-Solis, EnriqueArias Hurtado, JaimePalm, Björn

Search in DiVA

By author/editor
Mejia-Solis, EnriqueArias Hurtado, JaimePalm, Björn
By organisation
Applied Thermodynamics and Refrigeration
In the same journal
Heliyon
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 154 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf