kth.sePublications KTH
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Experiments and Simulations to Assess Exercise-Induced Pressure Drop Across Aortic Coarctations
Department of Bioengineering, Stanford University, Stanford, CA 94305, USA.
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Biomedical Engineering and Health Systems, Health Informatics and Logistics.ORCID iD: 0000-0002-7432-2139
Department of Pediatrics-Cardiology, Stanford University, Stanford, CA 94305; Department of Cardiothoracic Surgery, Stanford University, Stanford, CA 94305, USA.
Department of Pediatrics-Cardiology, Stanford University, Stanford, CA 94305; Department of Bioengineering, Stanford University, Stanford, CA 94305, USA.
Show others and affiliations
2025 (English)In: Journal of Biomechanical Engineering, ISSN 0148-0731, E-ISSN 1528-8951, Vol. 147, no 7Article in journal (Refereed) Published
Abstract [en]

Blood pressure gradient (ΔP) across an aortic coarctation (CoA) is an important measurement to diagnose CoA severity and guide treatment. While invasive cardiac catheterization is the clinical gold-standard for measuring ΔP, it requires anesthesia and does not capture the effects of daily activity or exercise, potentially underestimating the disease's functional burden. This study aimed to identify patients with functionally significant CoA by evaluating exercise-induced ΔP using a hybrid mock circulatory loop (HMCL). Patient-specific aorta geometries (N = 5) of patients with CoA were generated from 4D-Flow magnetic resonance imaging (MRI) scans, then three dimensional (3D)-printed to create compliant aortic phantoms. The phantoms were incorporated into an HMCL with flow and pressure waveforms tuned to patient-specific rest and exercise states. Matched fluid-structure interaction (FSI) simulations were performed using simvascular for comparison. Results showed that mean ΔP increased nonlinearly with cardiac output (CO), with trends differing between patients. HMCL and FSI simulations exhibited excellent agreement in trends of ΔP change with CO, with minimal error of 1.6±1.1 mmHg. This study emphasizes the need for assessing exercise CoA hemodynamics beyond resting ΔP measurements. Overall, HMCLs and FSI simulations enable assessment of patient-specific hemodynamic response to exercise unattainable in clinical practice, thereby facilitating a comprehensive noninvasive assessment of CoA severity. Further, the excellent agreement between HMCL and FSI results indicates that our validated FSI approach can be used independently to assess exercise CoA hemodynamics hereafter, eliminating the need for repeated complex HMCL experiments.

Place, publisher, year, edition, pages
ASME International , 2025. Vol. 147, no 7
Keywords [en]
aortic coarctation, fluid–structure interaction, hybrid mock circulatory loop, pressure drop
National Category
Cardiology and Cardiovascular Disease Radiology and Medical Imaging
Identifiers
URN: urn:nbn:se:kth:diva-368553DOI: 10.1115/1.4068716ISI: 001518990100001PubMedID: 40381185Scopus ID: 2-s2.0-105008358234OAI: oai:DiVA.org:kth-368553DiVA, id: diva2:1990376
Note

QC 20250820

Available from: 2025-08-20 Created: 2025-08-20 Last updated: 2025-10-03Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Perra, EmanueleDual, Seraina A.

Search in DiVA

By author/editor
Perra, EmanueleDual, Seraina A.
By organisation
Health Informatics and Logistics
In the same journal
Journal of Biomechanical Engineering
Cardiology and Cardiovascular DiseaseRadiology and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 61 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf