kth.sePublications KTH
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
A Nano-Sized Poly(aniline-co-thiophene) Based Solid-Contact Screen-Printed Electrode for Batch and Continuous Potentiometric Determination of Iodide
Department of Chemistry, Faculty of Science, Ain Shams University, Abbasia, Cairo 11566, Egypt.
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Chemistry, Applied Physical Chemistry. Department of Chemistry, Faculty of Science, Ain Shams University, Abbasia, Cairo 11566, Egypt.ORCID iD: 0000-0002-6873-2991
2026 (English)In: Polymers, E-ISSN 2073-4360, Vol. 18, no 4, article id 492Article in journal (Refereed) Published
Abstract [en]

Two approaches are described for construction of a screen-printed planar electrode (SPE) for potentiometric determination of iodide ion. The first, involves preparation and application of iron(II) bathophenanthroline tetraiodoplumbate complex ([Fe(bphen)3][PbI4]), as a sensitive and selective electroactive sensing material in a potentiometric electrode for iodide determination. The second is the use of a nano-sized poly(aniline-co-thiophene) (PANI-co-PT) as a solid-contact material in a planar miniaturized configuration. The SPE displays a Nernstian response for iodide ion with a calibration slope of −58.81 ± 0.69 mV/decade (R2 = 0.9998) over a wide concentration range (9.17 × 10−7–6.94 × 10−3 mol/L), low detection limit (6.09 × 10−7 mol/L), rapid response time (5.0 ± 1.0 s) and long-life span (75 ± 3.0 d). The use of PANI-co-PT solid-contact layer significantly improves the ion-to-electron transduction, eliminates the formation of undesired thin water layer between the sensing membrane and the conducting substrate, prevents membrane delamination, enhances potential stability with a significantly reduced potential drift (8.32 ± 0.12 µV/min) and displays high redox capacitance (2.560 ± 0.040 mF). Water contact angle measurements confirm the increased hydrophobicity of the modified membrane electrode (from 44 ± 0.8° to 93 ± 1.4°) and demonstrate the membrane ability to repel moisture and further stabilize the sensor response. The proposed sensor is successfully integrated into a flow injection analysis (FIA) system to enable real-time and continuous iodide monitoring with high precision, high sample throughput and applicability for quality control of pharmaceuticals and environmental monitoring.

Place, publisher, year, edition, pages
Sweden: MDPI AG , 2026. Vol. 18, no 4, article id 492
National Category
Analytical Chemistry
Research subject
Chemistry; Chemistry; Chemistry
Identifiers
URN: urn:nbn:se:kth:diva-385891DOI: 10.3390/polym18040492ISI: 001700129600001PubMedID: 41754681Scopus ID: 2-s2.0-105031559375OAI: oai:DiVA.org:kth-385891DiVA, id: diva2:2087543
Note

QC 20260721

Available from: 2026-07-21 Created: 2026-07-21 Last updated: 2026-07-21Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Fathy, Mahmoud Abdelwahab

Search in DiVA

By author/editor
Fathy, Mahmoud Abdelwahab
By organisation
Applied Physical Chemistry
In the same journal
Polymers
Analytical Chemistry

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 9 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf