kth.sePublications KTH
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
3D-Printed Hollow Microneedle Potentiometric Sensors: A Modular Approach
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Chemistry, Applied Physical Chemistry.ORCID iD: 0000-0003-0811-4259
Univ Catolica San Antonio Murcia, UCAM SENS, Avda Andres Hernandez Ros 1, Murcia 30107, Spain.
Univ Catolica San Antonio Murcia, UCAM SENS, Avda Andres Hernandez Ros 1, Murcia 30107, Spain.
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Chemistry, Applied Physical Chemistry.ORCID iD: 0000-0002-6128-5340
Show others and affiliations
2026 (English)In: ACS Sensors, E-ISSN 2379-3694, Vol. 11, no 7, p. 6191-6202Article in journal (Refereed) Published
Abstract [en]

Microneedle sensors represent a genuine approach to continuous health monitoring with minimally invasive access to skin interstitial fluid. However, their clinical deployment is hindered by complex fabrication and functionalization processes that compromise reproducibility and scalability. Truly, recent advancements in additive manufacturing have diminished certain obstacles; yet, single-modality techniques continue to encounter a significant trade-off between attaining high resolution and including electrochemical functionality. Accordingly, we introduce herein a novel modular hollow microneedle (HMN) architecture that separates insertion mechanics from ion sensing functionality. This new strategy synergistically integrates two complementary 3D printing modalities: high-resolution masked stereolithography (MSLA) to produce a robust, HMN shell, and fused filament fabrication (FFF) to fabricate a conductive pillar electrode to be modified with the ion-sensing role. The modularity of the sensor allows the pillar electrode to be functionalized prior to seamless assembly, protecting the sensing layer and ensuring robust and consistent potentiometric performance while addressing former drawbacks of the involved fabrication method: MSLA offers high-resolution hollow structures but is deficient in conductivity, whereas FFF facilitates conductive printing but suffers from restricted resolution. As a proof of concept, we have developed a potentiometric pH-HMN sensor that demonstrates excellent analytical performance, including a near-Nernstian response of -55.35 +/- 0.54 mV/pH, high repeatability (RSD = 0.61%), reproducibility (RSD = 1.16%), and stability (0.37 mV/h) during in vitro testing. A complete sensing architecture comprising a single 3D-printed patch with two HMN to house both the pH sensing pillar electrode and a reference pillar electrode has demonstrated high accuracy in ex vivo tests using rat skin samples, showing a mean absolute difference of less than 0.05 pH units compared to a commercial pH electrode. The developed modular platform streamlines manufacturing, enabling the rapid, low-cost, and scalable production of reliable microneedle sensors, paving the way for their widespread use to other ions and analytes as well as future testing in live subjects.

Place, publisher, year, edition, pages
American Chemical Society (ACS) , 2026. Vol. 11, no 7, p. 6191-6202
Keywords [en]
wearable sensors, additive manufacturing, solid contact, electrochemical sensor, sensor customization
National Category
Analytical Chemistry
Identifiers
URN: urn:nbn:se:kth:diva-387031DOI: 10.1021/acssensors.6c01291ISI: 001807989200001PubMedID: 42374835OAI: oai:DiVA.org:kth-387031DiVA, id: diva2:2091494
Note

QC 20260812

Available from: 2026-08-12 Created: 2026-08-12 Last updated: 2026-11-05Bibliographically approved
In thesis
1. Advancing Microneedle Sensors: From Measurement Scope to Fabrication Architecture
Open this publication in new window or tab >>Advancing Microneedle Sensors: From Measurement Scope to Fabrication Architecture
2026 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Continuous monitoring of biomarkers in dermal interstitial fluid (ISF) could bring clinically relevant information out of the laboratory and into daily life. Microneedles (MNs) offer a minimally invasive route to ISF. However, most MN sensors target a narrow set of chemical analytes, and their accuracy and reproducibility remain limited. This thesis examines three aspects of MN sensing that go beyond the sensing chemistry: the range of parameters that can be measured, the physical conditions at the sensing site, and the way the sensor is fabricated.

The work begins by extending MN electrochemical sensing to dissolved oxygen. A sensor based on platinum nanoparticles on stainless-steel MNs measured ISF oxygen in live rats. This study also revealed two limitations that shaped the rest of the thesis. The sensor response depended on temperature, and manual modification of microneedles caused device-to-device variation.

Each limitation was then addressed. A conducting polymer-based temperature sensor was built using 3D-printed hollow MN (HMN) to measure temperature directly at the sensing site. In parallel, a modular fabrication strategy was developed. It separates skin insertion from sensing: a printed HMN shell provides the mechanical skin penetration function, and a printed conductive pillar carries the sensing membrane. This design moves functionalization away from the fragile microneedle tip and yields potentiometric MN sensors with low device-to-device variation.

The two strategies finally converge in a single MN patch for potassium sensing, which combines a potassium-selective HMN, a solid-state reference HMN, and a temperature MN. This platform showed that temperature affects the formal potential as well as the Nernstian slope. It also showed that the reference electrode drifts to a degree comparable to that of the indicator electrode. Compensating the complete cell with the co-located temperature sensor significantly reduced measurement error in vitro.

Overall, the thesis moves from extending what MN sensors can measure to the architecture that makes such measurements reproducible. Reliability emerges as a system-level property, set collectively by sensing chemistry, physical context, and fabrication architecture. The modular, 3D-printed approach developed here provides a practical basis for reproducible and multimodal MN sensors.

Abstract [sv]

Kontinuerlig övervakning av biomarkörer i dermal interstitiell vätska (ISF) skulle kunna föra kliniskt relevant information ut ur laboratoriet och in i vardagen. Mikronålar (MN) erbjuder en minimalt invasiv väg till denna vätska. De flesta MN-sensorer riktar sig dock mot ett snävt urval av kemiska analyter, och deras noggrannhet och reproducerbarhet är fortfarande begränsade. Denna avhandling undersöker tre aspekter av mikronålssensorik som går utöver själva sensorkemin: vilka parametrar som kan mätas, de fysikaliska förhållandena vid mätstället och sättet på vilket sensorn tillverkas.

Arbetet inleds med att utvidga elektrokemisk mikronålssensorik till löst syre. En sensor baserad på platinananopartiklar på MN av rostfritt stål mätte syre i ISF hos levande råttor. Studien synliggjorde också två begränsningar som kom att forma resten av avhandlingen. Sensorns respons var temperaturberoende, och manuell modifiering av mikronålarna gav upphov till variation mellan enheter.

Var och en av dessa begränsningar hanterades därefter. En temperatursensor baserad på en ledande polymer byggdes in i 3D-printade ihåliga mikronålar (HMN) för att mäta temperaturen direkt vid mätstället. Parallellt utvecklades en modulär tillverkningsstrategi som separerar hudpenetrering från avkänning: en 3D-printad HMN-skalstruktur står för den mekaniska hudpenetrationen, medan en 3D-printad ledande pelare bär sensormembranet. Denna design flyttar funktionaliseringen bort från den sköra nålspetsen och ger potentiometriska MN-sensorer med låg variation mellan enheter.

De två strategierna förenas slutligen i ett enda mikronålsplåster för kaliummätning, som kombinerar en kaliumselektiv HMN, en fastfasbaserad referens-HMN och en temperatur-MN. Plattformen visade att temperaturen påverkar såväl formalpotentialen som Nernst-lutningen. Den visade också att referenselektroden uppvisar en drift jämförbar med indikatorelektrodens. Genom att kompensera hela cellen med hjälp av den samlokaliserade temperatursignalen minskades mätfelet markant in vitro.

Sammantaget går avhandlingen från att utvidga vad mikronålssensorer kan mäta till den arkitektur som gör sådana mätningar reproducerbara. Tillförlitlighet framträder som en egenskap på systemnivå, gemensamt bestämd av sensorkemin, den fysikaliska kontexten och tillverkningsarkitekturen. Det modulära, 3D-printade tillvägagångssätt som utvecklats här utgör en praktisk grund för reproducerbara och multimodala mikronålssensorer.

Place, publisher, year, edition, pages
Stockholm: KTH Royal Institute of Technology, 2026. p. 81
Series
TRITA-CBH-FOU ; 2026:49
Keywords
Microneedle sensor, Interstitial fluid, Electrochemical sensing, Oxygen sensor, Temperature sensor, Potentiometry, 3D printing, Temperature compensation, Mikronålssensor, Interstitiell vätska, Elektrokemisk sensorik, Syresensor, Temperatursensor, Potentiometri, 3D-printning, Temperaturkompensering
National Category
Analytical Chemistry
Research subject
Chemistry
Identifiers
urn:nbn:se:kth:diva-391765 (URN)978-91-8106-751-4 (ISBN)
Public defence
2026-12-10, Kollegiesalen, Brinellvägen 8, Stockholm, 10:00 (English)
Opponent
Supervisors
Funder
Swedish Research Council, VR-2023-04808Olle Engkvists stiftelse, 204-0214
Note

QC 20261105

Available from: 2026-11-05 Created: 2026-11-05 Last updated: 2026-11-05Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Authority records

Wei, QikunWang, QianyuCrespo, Gaston A.Cuartero, Maria

Search in DiVA

By author/editor
Wei, QikunWang, QianyuCrespo, Gaston A.Cuartero, Maria
By organisation
Applied Physical Chemistry
In the same journal
ACS Sensors
Analytical Chemistry

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 28 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf