kth.sePublications KTH
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Experimental and numerical study of a shell-and-tube latent thermal energy storage for solar thermal applications
Department of Civil and Mechanical Engineering, Technical University of Denmark, Brovej, Building 118, 2800Kgs, Lyngby, Denmark.
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Building Technology and Design.ORCID iD: 0000-0001-5916-7890
Department of Civil and Mechanical Engineering, Technical University of Denmark, Brovej, Building 118, 2800Kgs, Lyngby, Denmark.ORCID iD: 0000-0003-0706-2362
National Research Council (CNR) of Italy, Institute for Advanced Energy Technologies (CNR-ITAE), Messina, 98126, Italy.ORCID iD: 0000-0001-9330-7666
Show others and affiliations
2026 (English)In: Renewable energy, ISSN 0960-1481, E-ISSN 1879-0682, Vol. 276, article id 126349Article in journal (Refereed) Published
Abstract [en]

Shell-and-tube latent thermal energy storage plays a key role in buffering intermittent solar heat supply and ensuring reliable hot-water delivery in solar thermal systems. Previous studies have shown that shell-side flow maldistribution can cause short-circuiting and uneven heating between phase change material tubes, thereby degrading thermal performance. To address this issue, a perforated-plate-assisted latent thermal energy storage prototype was experimentally investigated, and a validated numerical model was used to clarify its internal thermodynamic behavior. The results show that the perforated plate markedly improves shell-side flow distribution and leads to excellent inter-tube uniformity during both charging and discharging. The liquid-fraction non-uniformity index between tubes is only 0.012 during charging and 0.0017 during discharging. However, the dominant non-uniformity appears as vertical stratification within individual tubes, with corresponding indices of 0.09 and 0.11. This vertical non-uniformity reduces effective heat utilization and degrades exergy performance. Higher flow rates enhance both charging and discharging rates. The maximum charging power and heat exchange capacity rate reach 3.1 kW and 343.61 W/K, respectively, while the maximum useful discharging power and heat exchange capacity rate reach 13.31 kW and 608.37 W/K. However, for practical domestic hot water applications, higher flow rates involve a trade-off: they increase hot water yield, but also lead to higher charging energy demand, lower average outlet temperature, and shorter useful supply duration. These findings show that the perforated plate effectively mitigates inter-tube non-uniformity, while future optimization should focus on suppressing intra-tube vertical stratification and adapting the flow-rate strategy to specific domestic hot water demands. 

Place, publisher, year, edition, pages
Elsevier BV , 2026. Vol. 276, article id 126349
Keywords [en]
Latent heat storage, Experiment verification, Numerical simulation, Thermodynamic performance, Uniformity investigation, Flow rate investigation
National Category
Materials Engineering Building Technologies
Identifiers
URN: urn:nbn:se:kth:diva-387574DOI: 10.1016/j.renene.2026.126349ISI: 001859933200001Scopus ID: 2-s2.0-105048089979OAI: oai:DiVA.org:kth-387574DiVA, id: diva2:2095569
Funder
Swedish Energy Agency, P2024-01185
Note

QC 20260827

Available from: 2026-08-26 Created: 2026-08-26 Last updated: 2026-09-03Bibliographically approved

Open Access in DiVA

fulltext(19959 kB)34 downloads
File information
File name FULLTEXT01.pdfFile size 19959 kBChecksum SHA-512
7f01926de5a0f084c42b511f6a8cdf14787341c9900360557da5c89ed1f75e4824137abbaa95030c2e103fe023fb2ef30fb6bad64ccb2030815d9d9487e5b142
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopus

Authority records

Chen, YangzheWang, Qian

Search in DiVA

By author/editor
Chen, YangzheGao, MengPalomba, ValeriaWang, QianFan, Jianhua
By organisation
Building Technology and Design
In the same journal
Renewable energy
Materials EngineeringBuilding Technologies

Search outside of DiVA

GoogleGoogle Scholar
Total: 34 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 538 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf