kth.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Vidareutveckling och test av koncentrator för studier av nanopartiklars hälsopåverkan
KTH, School of Industrial Engineering and Management (ITM), Engineering Design.
KTH, School of Industrial Engineering and Management (ITM), Engineering Design.
2025 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Further Development and Testing of a Concentrator for Studies on the Health Impacts of Nanoparticles (English)
Abstract [sv]

Som en del av ett EU-finansierat projekt, nPETS (GA 954377), bedrivs vid Stockholms universitet forskning på hur nanopartiklar från transportsektorn påverkar lungceller. Men eftersom koncentrationen av dessa nanopartiklar normalt är för låg och för att kunna studera effekterna krävs en ökad partikelkoncentration, vilket görs via en koncentrator baserad på ett tillväxtrör, med tre temperaturzoner, och en virtuell impaktor. En sådan koncentrator har tidigare utvecklats av studenter vid KTH, men denna var vid projektets start inte verifierad och krävde vidare utveckling. Denna rapport sammanfattar tidigare gjorda val, beskriver arbetsprocessen för att identifiera problem och de åtgärder som gjorts för att uppnå en fungerande koncentrator med koncentrationsfaktor på minst fem (5x), samtidigt som den ställda kravspecifikationen efterföljdes. Rapporten beskriver hur man kan säkerställa en fungerande kylning för tillväxtröret och beskriver efterföljande tester som skedde på respektive delsystem och koncentratorn som helhet. Vid testningen av delsystemen användes en nebulisator för att generera partiklar och en Optical Particle Counter (OPC) för att räkna dessa, medan helsystemstestet använde aerosoler från omgivande luft. Testerna av delsystemen visade impaktorns effektiva verkningsområde som 0.25-4 µm och tillväxtrörets maximala förstoringsökning, med temperaturerna 5 °C, 45 °C och 15 °C, vid intervallet > 0.35 till > 0.4 µm. Vid den slutliga verifieringen av hela systemet kunde den totala koncentrationsfaktorn uppmätas till 1.98 ± 0.115, vilket innebär att den efterfrågade koncentrationsfaktorn på 5x inte uppnås med rådande inställningar. Under projektet bestämdes inte heller den färdiga koncentratorns verkliga verkningsområde, och man vet därför inte vilken effekt koncentratorn har på de eftersökta nanopartiklarna.

Abstract [en]

As part of an EU-financed project, nPETS (GA 954377), research is carried out at Stockholm University on how nanoparticles from the transport sector affect lung cells. Because the concentration of those nanoparticles is usually too low to study, a higher concentration is needed. The higher concentration is attained through a concentrator, based on a growth tube with three different temperature zones, and a virtual impactor. Such a concentrator was developed by students at KTH but was unverified at the start of this project and required further development. This report summarizes previous choices and describes the work processes employed to identify and resolve issues, aiming to achieve a functional concentrator with a concentration factor of at least five (5x), while adhering to the requirements specification. The report describes how you could ensure a working cooling system for the growth tube, and describes the following tests for each subsystem, and the final end-to-end test. When testing the subsystems, a nebulizer was used to generate particles and an Optical Particle Counter (OPC) to count said particle, while the final test used the surrounding aerosols when conducted. The tests on the subsystems showed an effective range of the virtual impactor, between 0.25-0.4 µm, and the maximal magnification increase for the growth tube, with the temperatures 5 °C, 45 °C, and 15 °C, for the interval >0.35 to >0.4 µm. At the final verification of the whole system the concentration factor was measured to be 1.98 ± 0.115, which mean that it did not fulfil the requested concentration factor of 5x with the current settings. During the project, the working range of the final concentrator was not determined, and therefor, one does not know what effect the concentrator has on the sought nanoparticles.

Place, publisher, year, edition, pages
2025. , p. 29
Series
TRITA-ITM-EX ; 2025:97
Keywords [en]
Particle concentration, particle emissions, particle growth, virtual impactor
Keywords [sv]
Partikelemissioner, partikelkoncentrator, partikeltillväxt, virtuell impaktor
National Category
Mechanical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-369141OAI: oai:DiVA.org:kth-369141DiVA, id: diva2:1992901
External cooperation
SU
Subject / course
Machine Design
Educational program
Bachelor of Science in Engineering - Mechanical Engineering
Presentation
2025-05-23, 00:00
Supervisors
Examiners
Available from: 2025-08-28 Created: 2025-08-28 Last updated: 2025-08-28Bibliographically approved

Open Access in DiVA

fulltext(1067 kB)23 downloads
File information
File name FULLTEXT01.pdfFile size 1067 kBChecksum SHA-512
8ae02f6d992b0cee75b0e6d547800f7eb70e390a968f095331b893b940ce64aa2e3c264d7dadd57b3d9164ec78e037217f88faa17bee778e3294f1e40f3c1cc7
Type fulltextMimetype application/pdf

By organisation
Engineering Design
Mechanical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 23 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 553 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf