Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Numerical simulation of the impact of surgeon posture on airborne particle distribution in a turbulent mixing operating theatre
KTH, Skolan för arkitektur och samhällsbyggnad (ABE), Byggvetenskap, Strömnings- och klimatteknik.ORCID-id: 0000-0002-9361-1796
Vise andre og tillknytning
2016 (engelsk)Inngår i: Building and Environment, ISSN 0360-1323, E-ISSN 1873-684X, Vol. 110, s. 140-147Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Airborne particles released from surgical team members are major sources of surgical site infections. To reduce the risk of such infections, ultraclean-zoned ventilation systems have been widely applied, as a complement to the ventilation of the main operating theatre. The function of ventilation in an operating theatre is usually determined without considering the influence of the staff members' posture and movements. The question of whether the surgeon's posture during an on-going operation will influence particle distribution within the surgical area has not yet been explored in depth or well documented. In the present study we analysed data from investigation of two positions (bending and straightened up), which represent the most common surgeon and staff-member postures. The investigation was performed by applying the computational fluid dynamics methodology to solve the governing equations for airflow and airborne particle dispersion. Ultraclean-zoned ventilation systems were examined as an addition to the conventional operating theatre. We examined three distinct source strengths (mean value of pathogens emitted from one person per second) due to the variety of staff clothing systems. In the upright posture, the screen units reduced the mean air counts of bacteria and the mean counts of sedimenting bacteria to a standard level for infection-prone surgeries in the surgical area. However, the performance of this system could be reduced drastically by improper Work experience. Surgical garments with a high protective capacity result in lower source strength and thus reduces the particle concentration within the surgical area. These results are useful for developing best practices to prevent or at least reduce the infection rate during a surgical intervention.

sted, utgiver, år, opplag, sider
Elsevier, 2016. Vol. 110, s. 140-147
Emneord [en]
CFD simulation, Operating theatre, Ventilation system, Bacteria-carrying particles, Clothing system, Colony-forming unit, Mobile ultraclean zonal-laminar airflow screen
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-197758DOI: 10.1016/j.buildenv.2016.10.005ISI: 000388052500013Scopus ID: 2-s2.0-84992209616OAI: oai:DiVA.org:kth-197758DiVA, id: diva2:1063450
Merknad

QC 20170110

Tilgjengelig fra: 2017-01-10 Laget: 2016-12-08 Sist oppdatert: 2025-02-09bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Sadrizadeh, Sasan

Søk i DiVA

Av forfatter/redaktør
Sadrizadeh, Sasan
Av organisasjonen
I samme tidsskrift
Building and Environment

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 196 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf