Development of Ultrasound Pulse Sequences for Acoustic Droplet Vaporization
KTH, Skolan för kemi, bioteknologi och hälsa (CBH).
2019 (engelsk)Independent thesis Advanced level (degree of Master (Two Years)), 40 poäng / 60 hpOppgaveAlternativ tittel
Utveckling av ultraljudspulssekvenser för akustisk vaporisering av vätskedroppar (svensk)
Abstract [en]

Ultrasound-mediated drug delivery has been proposed as a safe and non-invasive method to achieve localized drug release. Drug-loaded microbubbles are injected in the vascular system and ultrasound waves are then used to localize and burst the microbubbles at a specific targeted area. The relatively large size of microbubbles however limits both their lifetime and their reach in the human body.

Phase-change liquid droplets can extend the use of ultrasound contrast agents for localized drug delivery. Their smaller size provides several advantages. The droplets can reach smaller capillaries, such as those in tumors vasculature. Their lifetime is also considerably prolonged.

Through the phenomenon of Acoustic Droplet Vaporization (ADV), triggered by ultrasound stimulation, the liquid-filled droplets experience a phase change and are converted into gas-filled microbubbles. The newly created microbubbles can then be disrupted by further stimulation and release their drug load in the tumor tissue.

In this project, a protocol to image and burst perfluoropentane-based micro-sized droplets using a single transducer is developed using the Verasonics Ultrasound System.

The pulse sequences are developed to allow close monitoring of the drug delivery by capturing a series of images before and after the vaporization or destruction of the droplets.

The droplets response was assessed for different pulse voltages and durations. Mean pixel value was calculated for the regions of interest, using the images captured before and after delivery of the ultrasound pulse.

Vaporization of the droplets can be achieved with low voltage (10V), whereas high voltage (50V) triggers their destruction.

Combined with high voltage, pulse duration affects the rate at which droplets can be destructed.

sted, utgiver, år, opplag, sider
2019. , s. 39
Serie
TRITA-CBH-GRU ; 2019:084
Emneord [en]
Ultrasound, Ultrasound contrast agents, Phase-change contrast agents, Acoustic droplet vaporization, Verasonics
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-253358OAI: oai:DiVA.org:kth-253358DiVA, id: diva2:1325197
Utdanningsprogram
Master of Science in Engineering - Medical Engineering
Presentation
2019-06-04, 17:45 (engelsk)
Veileder
Examiner
Tilgjengelig fra: 2019-06-20 Laget: 2019-06-14 Sist oppdatert: 2022-06-26bibliografisk kontrollert

Open Access i DiVA

fulltext(1914 kB)441 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1914 kBChecksum SHA-512
8c4b24f035397fcab98c618cc9b29b5079cf4f17789aada3674acae4d206018197f7cca501890b0c85f42e492b15cf6aa3f3081ce2707aec012f809064a01484
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 442 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 1123 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf