On ``Cavitation on Chip'' in Microfluidic Devices With Surface and Sidewall Roughness Elements
KTH, Skolan för kemi, bioteknologi och hälsa (CBH), Medicinteknik och hälsosystem, Medicinsk avbildning.ORCID-id: 0000-0003-4883-7347
Mechatronics Engineering Program, Faculty of Engineering and Natural Sciences, Sabanci University.ORCID-id: 0000-0002-6302-0004
Vise andre og tillknytning
2019 (engelsk)Inngår i: Journal of microelectromechanical systems, ISSN 1057-7157, E-ISSN 1941-0158, Vol. 28, nr 5, s. 890-899Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

In this paper, cavitating flows are characterized in 29 microfluidic devices in order to achieve a comprehensive perspective regarding flow patterns in microscale, which is crucial in the applications, such as energy harvesting and biomedical treatment. While the assessment of size effects is vital for the design and development of microfluidic devices involving phase change, surface/sidewall roughness and pressure pulses as a result of nanomechanical oscillations increase the performance with respect to cavitation by providing more cavitation bubbles. A typical device generates cavitating flows under different conditions (from inception to choked flow). In this device, a restrictive element and a big channel downstream of the restrictive element--where the cavitation is formed and developed--are included. The cavitating flows are obtained inside 24 sidewall roughened and 5 surface roughened/plain microfluidic devices at different pressure drops. The length and height of the sidewall roughness elements are varied to achieve the most optimum performance in terms of cavitation generation. Moreover, different surface roughened and plain devices are considered to provide a comprehensive overview of cavitation generation in microscale. The results show that sidewall roughness elements have a remarkable effect on the cavitation inception and flow patterns. [2019-0025] IEEE

sted, utgiver, år, opplag, sider
Institute of Electrical and Electronics Engineers Inc. , 2019. Vol. 28, nr 5, s. 890-899
Emneord [en]
Cavitation, fully developed twin cavities., inception, microfluidic device, roughness, Energy harvesting, Flow patterns, Fluidic devices, Microfluidics, Surface roughness, Biomedical treatment, Cavitation inception, Design and Development, Different pressures, fully developed twin cavities, Micro-fluidic devices, Nanomechanical oscillations
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-263269DOI: 10.1109/JMEMS.2019.2925541ISI: 000489837100019Scopus ID: 2-s2.0-85069910140OAI: oai:DiVA.org:kth-263269DiVA, id: diva2:1368052
Merknad

QC 20191105

Tilgjengelig fra: 2019-11-05 Laget: 2019-11-05 Sist oppdatert: 2024-05-20bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Ghorbani, MortezaMotezakker, Ahmad Reza

Søk i DiVA

Av forfatter/redaktør
Ghorbani, MortezaMotezakker, Ahmad Reza
Av organisasjonen
I samme tidsskrift
Journal of microelectromechanical systems

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 260 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf