Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Generation of uncertainty envelopes for thin acoustic screens with uncertain parameters
KTH, Skolan för teknikvetenskap (SCI), Farkost och flyg, MWL Marcus Wallenberg Laboratoriet. Le Mans Univ, LAUM UMR CNRS 6613, F-72085 Le Mans, France..ORCID-id: 0000-0001-9071-6325
Le Mans Univ, LAUM UMR CNRS 6613, F-72085 Le Mans, France..
KTH, Skolan för teknikvetenskap (SCI), Farkost och flyg, MWL Marcus Wallenberg Laboratoriet.ORCID-id: 0000-0003-1855-5437
Matelys Res Lab, F-69120 Vaulx En Velin, France..
2020 (engelsk)Inngår i: Acta Acustica, ISSN 2681-4617, Vol. 4, nr 3, artikkel-id 8Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The properties of the materials used for building sound proofing systems are known to exhibit large variations. These may lead to significant differences in the acoustic responses within a given material batch, particularly when resistive screens are used as a surface component for a multi-layered absorbing panel. In such thin films, it is mostly the thickness and the flow resistivity, but in some cases also the porosity, that are difficult to control in the production process. All these potential variations influence the acoustic response of the complete panel. In the present contribution, a method to isolate and evaluate the effect of uncertainties in a film is proposed. Using a transmission line approach, it is shown to be possible to predict the modification of the response induced by the uncertainties. The proposed technique is then adapted to determine uncertainty envelopes of the absorption coefficient, for experimentally acquired responses, that are closer to measured envelopes as compared to those generated using Monte Carlo simulations or simplified approaches. The method is tested both on numerical and experimental cases and shows, in both cases, a very good agreement with the reference solutions. Unlike Monte Carlo approaches, the proposed method does not require a massive computational effort which makes it suitable for real life applications.

sted, utgiver, år, opplag, sider
EDP Sciences , 2020. Vol. 4, nr 3, artikkel-id 8
Emneord [en]
Acoustics screens, Uncertainties, Thin layers, Poroelastic media
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-278632DOI: 10.1051/aacus/2020007ISI: 000543313000001Scopus ID: 2-s2.0-85124085323OAI: oai:DiVA.org:kth-278632DiVA, id: diva2:1455522
Merknad

QC 20200727

Tilgjengelig fra: 2020-07-27 Laget: 2020-07-27 Sist oppdatert: 2025-02-09bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Gaborit, MathieuGöransson, Peter

Søk i DiVA

Av forfatter/redaktør
Gaborit, MathieuGöransson, Peter
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 104 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf