Flue gas Condensate Cleaning via Air Gap Membrane Distillation
KTH, Skolan för industriell teknik och management (ITM), Energiteknik.ORCID-id: 0000-0003-0923-9010
KTH, Skolan för industriell teknik och management (ITM), Energiteknik, Kraft- och värmeteknologi.ORCID-id: 0000-0002-3661-7016
Scarab Development AB.
2020 (engelsk)Konferansepaper, Oral presentation only (Fagfellevurdert)
Abstract [en]

Combined heat and power plants (CHP) require advanced pollution controls in order to ensure acceptable environmental performance. Flue gas condensate cleaning is a critical operation in this regard, enabling high separation efficiencies for particles, heavy metals, polyaromatic hydrocarbons, and other contaminants – all while enhancing the thermal output of the CHP unit. The current trend is to employ membrane technologies such as reverse osmosis (RO) for purification and water recovery. Although RO-based treatment is a proven and mature technology, there are several disadvantages. RO operates with very high pressure differences, causing high mechanical loading and subsequent deterioration of membrane performance and lifetime. Moreover, biofouling is a well-known problem with RO, often requiring extensive use of harsh pretreatment chemicals. Concerning the limitations of RO, there is a need to consider alternative cleaning methods. For the purpose, membrane distillation is introduced as a promising technology for flue gas condensate cleaning in this study. The experimental tests have been performed using an Air Gap Membrane Distillation (AGMD) bench scale unit in order to determine the potential of membrane distillation (MD) for flue gas condensate cleaning. The real flue gas condensate samples were collected from Stockholm Exergi plant. The results show that high quality condensate was recovered having conductivity ~0.5 mS/m, pH ~5, TOC <0.5 ppm, TDS <10 ppm, COD <5 ppm, turbidity <1 NTU, total hardness <0.1 °dH and alkalinity <2.4 mg HCO3/L. Moreover, the outcomes present that MD also provides better performance as compared to RO in terms of contaminants concentration i.e., total ammonia <0.1 ppm, mercury <0.02 ppb, zinc <4 ppb and copper <1 ppb. Results from current study show that the treated condensate cannot only be reused as boiler water but disposing it into water bodies is also acceptable under strict environmental regulations.

sted, utgiver, år, opplag, sider
Sydney, Australia, 2020.
Emneord [en]
CHP plants, Flue gas condensate cleaning, Membrane Distillation, Separation efficiency
HSV kategori
Forskningsprogram
Kemiteknik; Energiteknik; Energiteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-281444OAI: oai:DiVA.org:kth-281444DiVA, id: diva2:1469083
Konferanse
International Membrane Science & Technology Conference
Forskningsfinansiär
StandUp
Merknad

QC 20200930

Tilgjengelig fra: 2020-09-21 Laget: 2020-09-21 Sist oppdatert: 2026-04-27bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Person

Noor, Imtisal-e-Martin, Andrew R.

Søk i DiVA

Av forfatter/redaktør
Noor, Imtisal-e-Martin, Andrew R.
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 383 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf