Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Flows and function of the Infant Flow neonatal continuous positive airway pressure device investigated with computational fluid dynamics
Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden.
KTH, Skolan för teknikvetenskap (SCI), Centra, Linné Flow Center, FLOW. KTH, Skolan för teknikvetenskap (SCI), Teknisk mekanik. KTH, Skolan för teknikvetenskap (SCI), Centra, BioMEx.ORCID-id: 0000-0002-6881-2094
Anaesthesiology and Intensive Care, Östersund Hospital, Östersund, Sweden.
Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden.
Vise andre og tillknytning
2021 (engelsk)Inngår i: Acta Paediatrica, ISSN 0803-5253, E-ISSN 1651-2227, Vol. 110, nr 3, s. 811-817Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Aim: The first dedicated neonatal continuous positive airway pressure (CPAP) device using variable flow was the Infant Flow. The system was pressure stable with a low resistance to breathing. The aim of this study was to describe the flow and function of the Infant Flow geometry using simulated breathing and computational fluid dynamics. Method: The original Infant Flow geometry was used with simulated term infant breathing at three levels of CPAP. The large eddy simulation methodology was applied in combination with the WALE sub-grid scale model. Results: The simulation fully resolved the flow phenomena in the Infant Flow geometry. The main flow feature during inspiration was support by gas entrainment and mixing. During expiration, the jet deflected towards the outlet with unstable impingement of the jet at the opposing edge. Conclusion: The proposed mechanism has previously been based on theoretical reasoning, and our results present the first detailed description of the Infant Flow. The pressure stability was based on a jet supporting inspiration by gas entrainment and then being deflected during exhalation. This confirmed previously assumed principles of function and flows within the geometry and provided a base for further developments. 

sted, utgiver, år, opplag, sider
Wiley , 2021. Vol. 110, nr 3, s. 811-817
Emneord [en]
computational fluid dynamics, continuous positive airway pressure, equipment design, infant premature
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-284155DOI: 10.1111/apa.15502ISI: 000560600300001PubMedID: 32726471Scopus ID: 2-s2.0-85089483940OAI: oai:DiVA.org:kth-284155DiVA, id: diva2:1476853
Merknad

QC 20250314

Tilgjengelig fra: 2020-10-15 Laget: 2020-10-15 Sist oppdatert: 2025-03-14bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Berg, NiclasPrahl Wittberg, Lisa

Søk i DiVA

Av forfatter/redaktør
Berg, NiclasPrahl Wittberg, Lisa
Av organisasjonen
I samme tidsskrift
Acta Paediatrica

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 120 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf