Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Cooling capacity of diffuse ceiling ventilation system and the impact of heat load and diffuse panel distribution
(Aalborg University)
KTH, Skolan för arkitektur och samhällsbyggnad (ABE), Byggvetenskap, Hållbara byggnader.ORCID-id: 0000-0001-7032-3049
(Aalborg University)
(Aalborg University)
Vise andre og tillknytning
2020 (engelsk)Inngår i: Building and Environment, ISSN 0360-1323, E-ISSN 1873-684X, Vol. 185, artikkel-id 107290Artikkel i tidsskrift, Editorial material (Fagfellevurdert) Published
Abstract [en]

Diffuse ceiling ventilation system is an air distribution system based on the low-impulse supply of air through the perforated panels installed as the suspended ceiling. A ceiling with diffuse supply typically consists of active and passive panels, where active panels allow airflow. Diffuse ceiling ventilation system has been proven to have a higher cooling capacity compared to conventional air distribution systems, e.g. mixing or displacement ventilation systems. Several parameters have an impact on the cooling capacity of the system though. The present research study evaluates the cooling capacity of the diffuse ceiling ventilation system in connection to two essential parameters, i.e. the distribution of heat load in the room and the distribution of active diffuse panels in the ceiling. The evaluation is based on full-scale experiments performed in a laboratory-controlled environment as well as numerical studies with Computational Fluid Dynamics (CFD) simulations. The cooling capacity of the system in several scenarios with different heat load and active diffuse panel distribution are compared under a certain thermal comfort condition. The results indicate the highest cooling capacity in the scenario with evenly distributed heat load in the room and compact distribution of active diffuse panels in the ceiling, while the active panels cover almost one-third of the suspended ceiling. The system is at its minimum cooling capacity in the scenario with compact heat load distribution in the room and disperse distribution of active diffuse panels in the ceiling.

sted, utgiver, år, opplag, sider
Elsevier, 2020. Vol. 185, artikkel-id 107290
Emneord [en]
Diffuse ceiling ventilation, Cooling capacity, CFD simulation, Parametric study
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-284798DOI: 10.1016/j.buildenv.2020.107290ISI: 000579911400038Scopus ID: 2-s2.0-85091339145OAI: oai:DiVA.org:kth-284798DiVA, id: diva2:1492897
Merknad

QC 20201118

Tilgjengelig fra: 2020-11-03 Laget: 2020-11-03 Sist oppdatert: 2022-06-25bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Sadeghian, ParastooSadrizadeh, Sasan

Søk i DiVA

Av forfatter/redaktør
Sadeghian, ParastooSadrizadeh, Sasan
Av organisasjonen
I samme tidsskrift
Building and Environment

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 177 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf