Does a fixed temperature-controlled airflow ventilation system reduce airborne infectious disease in clinics? A numerical investigation
KTH, Skolan för arkitektur och samhällsbyggnad (ABE), Byggvetenskap, Hållbara byggnader.ORCID-id: 0000-0001-7032-3049
Avidicare AB.
KTH, Skolan för arkitektur och samhällsbyggnad (ABE), Byggvetenskap, Hållbara byggnader.ORCID-id: 0000-0002-9361-1796
2021 (engelsk)Konferansepaper, Oral presentation with published abstract (Fagfellevurdert)
Abstract [en]

HVAC systems play an important role in moderating and controlling both surgical site infections and airborne infectious disease transmission in hospitals and clinics. Designing a proper HVAC system can minimize the airborne particles' concentration and prevent the spread of contaminated agents to the wound area, instruments and implants, and the medical team. Various ventilation system strategies have been developed to reduce the airborne particles in the air during the surgeries. The turbulent mixing, laminar airflow, and temperature-controlled airflowventilations are three common operating room ventilation systems used in rooms where major surgeries are conducted. However, mobile ventilation systems are mostly applied for minor surgeries and dental treatments that mainly supply a mixing airflow with random directions.Several studies revealed that instead using a mobile laminar airflow ventilation system successfully reduced the contamination level; however, the washing effect of such systems is limited to distance and location. In this regard, this research investigates the impact of using a novel fixed ventilation system based on the principle of temperature-controlled airflow on the reduction of both the SSI and cross-contamination risks in patients and medical teams during minor surgeries. The airflow behavior and airborne particle distribution are simulated by using computational fluid dynamics (CFD) techniques.

sted, utgiver, år, opplag, sider
2021.
Emneord [en]
Ventilation systems, Airborne particles, Minor surgery
HSV kategori
Forskningsprogram
Byggvetenskap, Strömnings- och klimatteori
Identifikatorer
URN: urn:nbn:se:kth:diva-300102OAI: oai:DiVA.org:kth-300102DiVA, id: diva2:1587510
Konferanse
Healthy Buildings 2021, Hawaii, USA
Merknad

QC 20211110

Tilgjengelig fra: 2021-08-24 Laget: 2021-08-24 Sist oppdatert: 2022-06-25bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Person

Sadeghian, ParastooSadrizadeh, Sasan

Søk i DiVA

Av forfatter/redaktør
Sadeghian, ParastooSadrizadeh, Sasan
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 196 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf