Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Ageing state identification and analysis of AC submarine cable based 500 kV XLPE on high-voltage frequency dielectric response
State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, China.
State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, China.
State Grid Zhejiang Electric Power Supply Company Zhoushan Power Supply Company, Zhoushan, China.
Suzhou Angyao Electric Technology Co., Ltd, China.ORCID-id: 0000-0001-9128-7825
Vise andre og tillknytning
2020 (engelsk)Inngår i: IET Science, Measurement & Technology, ISSN 1751-8822, E-ISSN 1751-8830, Vol. 14, nr 8, s. 977-984Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Carrying out the insulation condition measurement and analysis is important for the safe operation of the submarinecable. In this study, the high-voltage frequency dielectric response is used to identify the ageing state of the AC 500 kV cross-linked polyethylene (XLPE) submarine cable. The complex capacitance and tanδ in the low-frequency area for the new, thermal ageing, electro-thermal ageing cable all increase with the testing voltage increased from 200 to 2000 V. It is founded that the dielectric response at high voltage is more likely to detect the ageing differences. Based on the carbonyl index and the dielectric loss of the XLPE specimens at different position of the insulation layer, the non-uniform ageing phenomenon of the cable insulation is presented for the thermal ageing and electro-thermal ageing cable. The loss quantity parameter and its changing behaviour with testing voltage based on the frequency dielectric response could be used to identify the ageing state. The comparison of the modified Cole–Cole model parameter under 200 and 2000 V also indicates that the higher voltage dielectric response is helpful to identify the ageing differences.

sted, utgiver, år, opplag, sider
2020. Vol. 14, nr 8, s. 977-984
HSV kategori
Forskningsprogram
Elektro- och systemteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-303105DOI: 10.1049/iet-smt.2020.0056ISI: 000582139600018Scopus ID: 2-s2.0-85092649406OAI: oai:DiVA.org:kth-303105DiVA, id: diva2:1600850
Merknad

QC 20211011

Tilgjengelig fra: 2021-10-06 Laget: 2021-10-06 Sist oppdatert: 2026-05-18bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Cheng, Jialu

Søk i DiVA

Av forfatter/redaktør
Cheng, Jialu
I samme tidsskrift
IET Science, Measurement & Technology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 69 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf