Assessment of diffuse ceiling ventilation performance on transmission of airborne infectious diseases
KTH, Skolan för arkitektur och samhällsbyggnad (ABE), Byggvetenskap, Hållbara byggnader. (Fluid and climate Technology)ORCID-id: 0000-0001-7032-3049
KTH, Skolan för arkitektur och samhällsbyggnad (ABE), Byggvetenskap, Hållbara byggnader.ORCID-id: 0000-0002-9361-1796
2022 (engelsk)Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Ventilation systems have been widely used to satisfy the occupants' indoor air quality and thermally comfort conditions. Various air distribution systems have been developed to supply clean air, including mixing, displacement, and diffuse ceiling ventilation systems. Diffuse ceiling systems are recent air distribution systems that supply cold air to the occupant area using perforated diffuse panels. These systems distribute air with a low velocity, minimizing the draft risk and dissatisfaction in highly dense spaces. The transmission risk of airborne infectious diseases like Covid-19 from the infected patient is high in waiting rooms. Thus, there is a demand to assure a secure environment for medical staff and patients in the waiting rooms. This study aims to numerically investigate the impact of the relative distance of the contamination source and exhaust on the transmission of airborne infectious diseases in the waiting room equipped with the diffuse ceiling ventilation system. In this regard, the release of Covid-19 from 4 different patients was investigated separately using the computational fluid dynamics technique. The distribution of the airborne infectious diseases is simulated by releasing SF6 tracer gas. The simulation result revealed that the contaminated patient located adjacent to the room’s outlet had no contamination risk for other patients and staff in the waiting room.

sted, utgiver, år, opplag, sider
International Society of Indoor Air Quality and Climate , 2022.
Emneord [en]
Diffuse ceiling ventilation system, Indoor air quality, Computational fluid dynamics, Tracer gas, Covid-19
HSV kategori
Forskningsprogram
Byggvetenskap, Strömnings- och klimatteori
Identifikatorer
URN: urn:nbn:se:kth:diva-311614Scopus ID: 2-s2.0-85159204362OAI: oai:DiVA.org:kth-311614DiVA, id: diva2:1655201
Konferanse
Indoor Air 2022 the 17th International Conference on Indoor Air Quality and Climate, June 12th to 16th Kuopio, Finland
Forskningsfinansiär
Swedish National Infrastructure for Computing (SNIC), 2018-05973
Merknad

QC 20220629

Tilgjengelig fra: 2022-05-01 Laget: 2022-05-01 Sist oppdatert: 2023-08-14bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

ScopusConference home page

Person

Sadeghian, ParastooSadrizadeh, Sasan

Søk i DiVA

Av forfatter/redaktør
Sadeghian, ParastooSadrizadeh, Sasan
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 414 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf